------------------------------ Code: 12076?FF Display: "PMC?(ICM,SCU?) Error Code:********" (QP2) PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP203,QP132 Cause: Undefined error in X-axis servopa…
------------------------------
Code: 12076?C2
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Detected Wrong Phase" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: X-axis servopack phase error detected (for new incremental encoder only)
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether the encoder wire has become broken or short-circuited.
------------------------------
Code: 12076?C3
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Phase PA/PB Disconnected" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: X-axis servopack phase PA or PB is disconnected.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether the encoder wire has become broken or short-circuited.
------------------------------
Code: 12076?C4
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Phase PC Disconnected" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: X-axis servopack phase PC is disconnected.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether the encoder wire has become broken or short-circuited.
------------------------------
Code: 12076?C5
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"PG Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: X-axis servopack PG error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether the encoder wire has become broken or short-circuited.
------------------------------
Code: 12076?F3
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Momentary Power Failure" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Momentary power failure alarm in X-axis servopack (detected when power is resupplied during
power maintenance interval).
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Turn the PMC off and on again, then restart from zero setting.
第 784 页
------------------------------
Code: 12076?FF
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Undefined error in X-axis servopack.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Turn the PMC off and on again, then restart from zero setting.
------------------------------
Code: 12078?02
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Y-axis(-) Overtravel" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The Y-axis has overtraveled in the (-) direction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Use inching to cancel the overtravel.
------------------------------
Code: 12078?03
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Y-axis(+) Overtravel" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The Y-axis has overtraveled in the (+) direction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Use inching to cancel the overtravel.
------------------------------
Code: 12078?04
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Y-axis Servo Amp Error" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis servo driver error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether something is interfering with the axis, whether the axis action has become
extremely heavy, or whether an error has occurred in the servo amp.
------------------------------
Code: 12078?05
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Y-axis PG Disconnection Err" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis PG disconnection error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether the connector has become disconnected from the servo axis, or whether an error
has occurred in the servo amp.
第 785 页
------------------------------
Code: 12078?0B
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Y-axis Positioning Time Out" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis positioning timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether something is interfering with the axis, whether the axis action has become
extremely heavy, or whether an error has occurred in the servo amp.
------------------------------
Code: 12078?0C
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Deviation Count Overflow(Y)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Y-axis deviation overflow.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether something is interfering with the axis, whether the axis action has become
extremely heavy, or whether an error has occurred in the servo amp.
------------------------------
Code: 12078?0D
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Y-axis (-) Software Limit" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The axis movement target value has exceeded the software limit in the (-) direction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the program coordinates and the Proper data values.
------------------------------
Code: 12078?0E
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Y-axis (+) Software Limit" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The axis movement target value has exceeded the software limit in the (+) direction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the program coordinates and the Proper data values.
------------------------------
Code: 12078?10
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Overcurrent/PWT Overheat" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Either excessive current or overheating of the power transistor has been detected in the Y-axis
servopack.
(value replacing "?" is module number; error code appears in place of asterisks)