FUJI错误代码查询.pdf - 第1766页
------------------------------ Code: 1D658112 Display: Used by: Cause: Lead_length_x in Part data has not been specified. Remedy: Specify Lead_length_x in Part data. ------------------------------ Code: 1D658113 Display:…
Cause: A range error occurred during vision processing and the operation was cancelled.
Remedy: Check that the nozzle is clean, that no foreign matter is stuck to the part, and that the part itself
is the correct one.
------------------------------
Code: 1D65001F
Display: 0031
Used by:
Cause: There are more leads on the part than the number entered in Part data (PDG).
Remedy: Check the number of leads entered in Part data (PDG), the direction, and lead information.
Check the orientation of the part as it is fed into the machine.
------------------------------
Code: 1D650020
Display: 0032
Used by:
Cause: The edge cannot be found.
Remedy: Check the number of leads entered in Part data (PDG), the direction, and lead information.
Check the orientation of the part as it is fed into the machine.
------------------------------
Code: 1D650021
Display: 0033
Used by:
Cause: A lead could not be found by searching 1/3 of the body, but when vision processing started again
a range error occurred.
Remedy: Check the number of leads entered in Part data (PDG), the direction, and lead information.
Check the orientation of the part as it is fed into the machine.
------------------------------
Code: 1D658002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D658100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D658110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D658111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
第 1765 页
------------------------------
Code: 1D658112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D658113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D658114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D658115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D658120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D658121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D658122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D658123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D6582??
Display:
第 1766 页
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D6583??
Display:
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D6584??
Display:
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D6585??
Display:
Used by:
Cause: The body is too short in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D6588??
Display:
Used by:
Cause: A lead on the left side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D6589??
Display:
Used by:
Cause: A lead on the left side of the part is too short. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D658A??
Display:
Used by:
Cause: A lead on the lower side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D658B??
Display:
Used by:
Cause: A lead on the lower side of the part is too short. The final two digits indicate the lead number.
第 1767 页