------------------------------ Code: 11082341 Display: Illegal Part is Sub Nozzle (Remove Part) Used by: MTU4 Cause: This error occurs when the machine judges that there is an undefined part on the sub-nozzle (for exampl…

100%1 / 5282
Code: 11082310
Display: Pickup Recovery Counter Limit Reached
Used by: MTU3,MTU4,MTU5
Cause: The sub-nozzle was unable to pick up a part in the tray and therefore reattempted to pick up the
part the specified number of times, again without success.
Remedy: Check that the tray is correctly positioned and that the parts with in the tray are correctly
positioned. Also check that correct data has been specified in part data.
------------------------------
Code: 11082330
Display: Nozzle Selection Error
Used by: MTU4
Cause: A nozzle which cannot be used on the MTU was specified.
Remedy: Reset the error at the IP machine. If the error occurs repeatedly, contact Fuji.
------------------------------
Code: 11082331
Display: Y Axis Deceleration Sensor is Not ON at Nozzle change
Used by: MTU4
Cause: When an attempt was made to change a nozzle, the Y axis speed reduction sensor was not on.
Remedy: Adjust the Y axis speed reduction sensor and the dog. In addition check that suitable data has
been entered for the MTU Proper data item Carrier_Position_SY.
------------------------------
Code: 11082332
Display: Z Axis Deceleration Sensor is Not ON at Nozzle change
Used by: MTU4
Cause: When an attempt was made to change a nozzle, the Z axis speed reduction sensor was not on.
Remedy: Adjust the Z axis speed reduction sensor and the dog. In addition check that suitable data has
been entered for the MTU Proper data item Parts_Pos_Zt0.
------------------------------
Code: 11082333
Display: Nozzle Pos. Sensor Error
Used by: MTU4
Cause: When the nozzle rotated, the nozzle position sensors did not turn on at the correct positions.
Remedy: Check the nozzle position sensors and the dogs.
------------------------------
Code: 11082334
Display: Nozzle Changer is Not at Retract Limit Position
Used by: MTU4
Cause: During nozzle change, the nozzle changer retract end sensor was not on.
Remedy: Adjust the nozzle changer retract end and advance end sensors.
------------------------------
Code: 11082335
Display: Nozzle Changer is Not at Forward Limit Position
Used by: MTU4
Cause: During nozzle change, the nozzle changer advance end sensor was not on.
Remedy: Adjust the nozzle changer advance end sensor and the dog.
------------------------------
Code: 11082340
Display: Parts Dropped From Sub-Nzl (Remove Part)
Used by: MTU4
Cause: A part picked up by the sub-nozzle was dropped while the Z axis was ascending.
Remedy: Remove the part which was dropped.
第 219 页
------------------------------
Code: 11082341
Display: Illegal Part is Sub Nozzle (Remove Part)
Used by: MTU4
Cause: This error occurs when the machine judges that there is an undefined part on the sub-nozzle (for
example, the operator may have intentionally placed a part on the sub-nozzle).
Remedy: If there is a part on the sub-nozzle, remove it. Furthermore, check the part detection sensor.
------------------------------
Code: 11082350
Display: Part Not Been Transferred From Sob-nozzle to Carrier
Used by: MTU4
Cause: A picked part was dropped while the Z axis was moving from its ascent position to the position
where the part is placed on the carrier.
Remedy: Remove the part which was dropped
------------------------------
Code: 11082351
Display: Part Dropped During Carrier Movement (Remove Part)
Used by: MTU4
Cause: The part being moved into the machine by the carrier fell off the carrier.
Remedy: Remove the part which fell.
------------------------------
Code: 11082352
Display: Part Pusher Up Limit Sensor is Not ON
Used by: MTU4
Cause: When the clamp installed at the carrier 2nd position was raised, the up sensor did not come on.
Remedy: Check that air is being supplied and that the clamp mechanism and up sensor are functioning
normally.
------------------------------
Code: 11082353
Display: Part Pusher Down Limit Sensor is Not ON
Used by: MTU4
Cause: When the clamp installed at the carrier 2nd position was lowered, the down sensor did not come
on.
Remedy: Check that air is being supplied and that the clamp mechanism and down sensor are
functioning normally.
------------------------------
Code: 11082354
Display: Illegal Part is On Carrier (Remove Parts On Carrier)
Used by: MTU4
Cause: This error occurs when the machine judges that there is an undefined part on the carrier (for
example, the operator may have intentionally placed a part on the carrier).
Remedy: If there is a part on the carrier, remove it. Furthermore, check the part detection sensors at the
1st and 2nd positions.
------------------------------
Code: 11082355
Display: Carrier No.2 Pos. is In Part Data In Spite of No Part Pusher
Used by: MTU4
Cause: This error occurs if the 5th bit in the MTU4 Proper data item Machine_status is set to 0 (
indicating that the part clamp is not fitted), but in part data the 2nd position is specified.
Remedy: Check that there are no parts for which Carrier_select in part datais set to 1 (the 2nd position
setting) and that even if the parts clamp is installed, the 5th bit from the right in Machine_status is set to
第 220 页
0.
------------------------------
Code: 11082360
Display: Waffle Tray Overloaded Remove Part
Used by: MTU4
Cause: Too many waffle trays have been stacked up.
Remedy: Remove the overstacked waffle trays.
------------------------------
Code: 11082370
Display: Reject Tray Box Full
Used by: MTU4
Cause: This error occurs when discarded trays accumulate, causing the sensor beam to be cut for a
continued period of time.
Remedy: Remove the accumulated trays. Check the adjustment of the sensors. Check that there are no
other objects in the tray area.
------------------------------
Code: 11082380
Display: Tray Reject Error
Used by: MTU4
Cause: This error occurs when a tray which is to be ejected is released at the eject position but the eject
sensor does not detect the falling tray.
Remedy: If the tray cannot be picked up, adjust the tray pick up point set in part data's Tray_pickup_pnt
and check that the tray can be picked up. Furthermore, if this error occurs even when the tray is picked
up, check the sensor.
------------------------------
Code: 11082390
Display: Tray Plate Setting Error
Used by: MTU4
Cause: The tray plate set sensor was activated while the T axis was moving.
Remedy: Check that the tray plate door is not open and that the tray plate is firmly positioned.
------------------------------
Code: 110823A0
Display: No Tray
Used by: MTU4
Cause: There are no trays but manual tray positioning was attempted.
Remedy: Supply trays.
------------------------------
Code: 110823B0
Display: Tray Space Chk Sens. Not ON
Used by: MTU4
Cause: The robot safety sensor was not on when the Y axis moved to pick up a tray part or to eject a
tray.
Remedy: Check the robot safety sensor and the dog. Also check that a suitable value is entered for the
MTU Proper data item Origin_Position_T0 to ensure that the T axis origin is at the correct position.
------------------------------
Code: 110823C0
Display: Tray Number Internal Error
Used by: MTU3,MTU4,MTU
Cause: During tray positioning, an abnormal tray number was detected.
Remedy: Initialize the memory.
------------------------------