FUJI错误代码查询.pdf - 第1319页
Remedy: Check the orientation of the parts when they are fed to the machine. ------------------------------ Code: 1D080012 Display: Used by: Cause: The opposing leads are too long. The body is too large. Remedy: Check th…
------------------------------
Code: 1D080009
Display:
Used by:
Cause: The lead is missing.
Remedy: Check the number of leads, and check the orientation of the parts when they are fed to the
machine. The lead has to have a certain thickness to be detected. If the lead thickness is not within +-
50% of the thickness set in Part dat this error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D08000B
Display:
Used by:
Cause: The lead width is too wide.
Remedy: Check the thickness of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part dat this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D08000C
Display:
Used by:
Cause: The lead width is too wide.
Remedy: Check the thickness of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part dat this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D08000D
Display:
Used by:
Cause: The lead width is too long.
Remedy: Check the length of the lead. Check the part. The lead has to have a certain thickness to be
detected. If the lead thickness is not within +-50% of the thickness set in Part dat this error can occur.
Check the part lead and the CCD level.
------------------------------
Code: 1D08000F
Display:
Used by:
Cause: Processing error.
Remedy: Check the part shape, and check whether or not the part exists.
------------------------------
Code: 1D080010
Display:
Used by:
Cause: The lead pitch is incorrect.
Remedy: Check the lead pitch and the number of leads on the part. The lead has to have a certain
thickness to be detected. If the lead thickness is not within +-50% of the thickness set in Part dat this
error can occur. Check the part lead and the CCD level.
------------------------------
Code: 1D080011
Display:
Used by:
Cause: The part tilt is too large.
第 1318 页
Remedy: Check the orientation of the parts when they are fed to the machine.
------------------------------
Code: 1D080012
Display:
Used by:
Cause: The opposing leads are too long. The body is too large.
Remedy: Check the size of the part. The lead has to have a certain thickness to be detected. If the lead
thickness is not within +-50% of the thickness set in Part data this error can occur. Check the part lead
and the CCD level.
------------------------------
Code: 1D088002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D088100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D088110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D088111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D088112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D088113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D088114
Display:
Used by:
第 1319 页
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D088115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D088120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D088121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
Remedy: Specify Qty_1.
------------------------------
Code: 1D088122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D088123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D0882??
Display:
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0883??
Display:
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D0884??
Display:
Used by:
Cause: The body is too long in the Y direction.
第 1320 页