FUJI错误代码查询.pdf - 第1153页

Code: 15040774 Display: LD MX MOVE TUP Loader error: 15040774 Used by: QP132 Cause: The MX-axis movement of the loading side manipulator was not completed within the set amount of time. Remedy: A servo alarm has occurred…

100%1 / 5282
Display: LD MANI DOWN TUP
Loader error: 15040769
Used by: QP132
Cause: The in-conveyor manipulator's lowering motion did not finish in the given time.
Remedy: Check the PCB loader's lower position (X059: PCB LD DWNCHK) operation using I/O commands
and adjust if necessary.
------------------------------
Code: 1504076A
Display: LD MANI PCB PICKUP ERROR
Loader error: 1504076A
Used by: QP132
Cause: The loading side manipulator failed to grab the board on the in-conveyor during the pick
operation.
Remedy: Check the operation of the in-conveyor board-arrival-check sensor and the entry transport
board-check sensor.
------------------------------
Code: 1504076B
Display: LD MANI PCB PLACE ERROR
Loader error: 1504076B
Used by: QP132
Cause: The loading side manipulator failed to place the board in the pallet.
Remedy: Make sure that the board did not slip off during the manipulator movement. Verify whether or
not the board unclamp operation is working correctly. Check the operating status of the entry transport
board-check sensor. Verify whether or not the board was placed in the correct position in the pallet.
------------------------------
Code: 1504076E
Display: LD MANI PCB LOSE ERROR
Loader error: 1504076E
Used by: QP132
Cause: The board was lost during movement of the loading side manipulator.
Remedy: Check that the board did not slip off during the manipulator movement. Check the operating
status of the entry transport board-check sensor.
------------------------------
Code: 15040770
Display: LD MANI TURN TUP
Loader error: 15040770
Used by: QP132
Cause: The rotation operation of the loading side manipulator was not completed within the set amount
of time.
Remedy: Check the rotation operation of the loading side manipulator and the operation of the entry
board transport rotation sensor.
------------------------------
Code: 15040771
Display: LD MANI BACK TUP
Loader error: 15040771
Used by: QP132
Cause: The return rotation operation of the loading side manipulator was not completed within the set
amount of time.
Remedy: Check the return operation of the loading side manipulator and the operation of the entry board
transport return sensor.
------------------------------
第 1152 页
Code: 15040774
Display: LD MX MOVE TUP
Loader error: 15040774
Used by: QP132
Cause: The MX-axis movement of the loading side manipulator was not completed within the set amount
of time.
Remedy: A servo alarm has occurred. Rectify the servo alarm status and then restart.
------------------------------
Code: 15040776
Display: LD MANI RISE FAIL
Loader error: 15040776
Used by: QP132
Cause: The entry board transport upper-limit sensor went off during movement of the loading side
manipulator.
Remedy: Make sure that the air pressure used to raise the board, which has been transported in, has not
fallen. Check the operation of the entry board transport upper-limit sensor.
------------------------------
Code: 15040778
Display: IN_CVR PCB STEY FAIL
Loader error: 15040778
Used by: QP132
Cause: A board remained on the in-conveyor when the loading side manipulator completed the operation
of grabbing a board from the in-conveyor.
Remedy: Check the operation of the in-conveyor board-arrival-check sensor. The in-conveyor board-
arrival-check sensor should be in the off status when the loading side manipulator has finished grabbing
the board from the in-conveyor and raising it.
------------------------------
Code: 15040780
Display: LD 10-SHIFT FORWARD TUP
Loader error: 15040780
Used by: QP132
Cause: The in-conveyor side's pallet 10 mm shift to the right operation did not finish in the given time.
Remedy: Check the loading pallet's right shift position (X054: P.IN PLT RSFT) operation using I/O
commands and adjust if necessary.
------------------------------
Code: 15040781
Display: LD 10-SHIFT BACKWARD TUP
Loader error: 15040781
Used by: QP132
Cause: The in-conveyor side's pallet 10 mm shift to the left operation did not finish in the given time.
Remedy: Check the loading pallet's left shift position (X055: P.IN PLT LSFT) operation using I/O
commands and adjust if necessary.
------------------------------
Code: 15040782
Display: LD TRANS FORWARD TUP
Loader error: 15040782
Used by: QP132
Cause: The pallet pusher that moves a pallet from the return-conveyor to the pallet loader did not finish
extending in the given time.
Remedy: Check the X04A: RCV PUSH FWEND operation using I/O commands and adjust if necessary.
------------------------------
第 1153 页
Code: 15040783
Display: LD TRANS BACKWARD TUP
Loader error: 15040783
Used by: QP132
Cause: The pallet pusher that moves a pallet from the return-conveyor to the pallet loader did not finish
retracting in the given time.
Remedy: Check the X04B: RCV PUSH BWEND operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040784
Display: RCV-LD CHANGE TUP
Loader error: 15040784
Used by: QP132
Cause: The loader's pallet sensor did not come on when the pallet was moved from the return-conveyor
to the pallet loader.
Remedy: Check the X050: P.IN ARRV CK operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040801
Display: PO POSITIONING ERROR
Loader error: 15040801
Used by: QP132
Cause: There is a difference of at least 10 pulses between the movement command position and the
current position of the PO-axis.
Remedy: Make sure there is no load on the PO-axis, and restart.
------------------------------
Code: 15040856
Display: UNLD PCB CLAMP TUP
Loader error: 15040856
Used by: QP132
Cause: The unloaded pallet closed check (X064: P.OUT PLT CLS) did not come on in the given time (QP-
132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040857
Display: UNLD PCB UNCLAMP TUP
Loader error: 15040857
Used by: QP132
Cause: The unloaded pallet open check (X063: P.OUT PLT OPN) did not come on in the given time (QP-
132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040860
Display: UNLD BACKWARD TUP
Loader error: 15040860
Used by: QP132
Cause: The pallet unloaded cylinder retract sensor (X062: P.OUT BWD) did not come on in the given time
(QP-132).
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 15040861
Display: UNLD FORWARD TUP
Loader error: 15040861
第 1154 页