FUJI错误代码查询.pdf - 第1130页

------------------------------ Code: 1504033E Display: Middle loading sensor error. Used by: CP-732E, CP-742ME, CP-742E Cause: The XY-table loading height sensor (X05C) is not operating properly. This sensor fails to swi…

100%1 / 5282
Cause: Only the second panel is present.
Remedy: Check to see if the first panel is being conveyed properly.
------------------------------
Code: 15040335
Display: Main conveyor unclamp limit sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Main conveyor unclamp limit sensor input error.
Remedy: Check to see if the sensors (X061, X062, X064) are operating properly.
------------------------------
Code: 15040336
Display: Main conveyor clamp limit sensor input error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Main conveyor clamp limit sensor input error.
Remedy: Check to see if the sensors (X05F, X060, X063) are operating properly.
------------------------------
Code: 15040337
Display: Main conveyor clamp limit and unclamp limit sensor logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Main conveyor clamp limit and unclamp limit sensor logic error.
Remedy: Verify that all sensors (X05F to X064) are operating properly.
------------------------------
Code: 15040338
Display: Loading position sensor error.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: Logic check error at loading position sensors. The sensors at both the IN and OUT sides are on.
Remedy: Verify that the sensors (X0BF to X0DA) are operating properly.
------------------------------
Code: 15040339
Display: Main lifter sensor logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The main lifter UP sensor and the main lifter OT sensor are both on.
Remedy: Verify that the sensors (X05C to X05E) are operating properly.
------------------------------
Code: 1504033A
Display: Table height sensor logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: A logic error occurred at the table height sensor when placing parts. The DOWN limit sensor
switched off.
Remedy: Verify that the table height sensor is operating properly.
------------------------------
Code: 1504033B
Display: XY-table travel time-up.
Used by: CP-732E, CP-742ME, CP-742E, CP-752E
Cause: XY-table travel was not completed within the prescribed period of time.
Remedy: Check for objects which may be interfering with XY-table travel.
------------------------------
Code: 1504033C
Display: Loader unit error
Used by: NP2,QP3
Cause: Error occurred between the machine and the motor control panel.
Remedy: Restart the machine.
第 1129 页
------------------------------
Code: 1504033E
Display: Middle loading sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The XY-table loading height sensor (X05C) is not operating properly. This sensor fails to switch
on when the Z-axis is at the middle loading position. Alternatively, this sensor switches on when the Z-
axis is not at the middle loading position +/-500 pulses.
Remedy: Adjust the mounting position of the XY-table loading height sensor (X05C).
------------------------------
Code: 1504033F
Display: Panel check error
Used by: CP-732E, CP-742ME, CP-742E
Cause: The sensor check results differ from the machine's current status memory.
Remedy: Adjust the position of the sensor as required so that the panel on the main conveyor is correctly
detected.
------------------------------
Code: 15040340
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: A panel was loaded onto the main-conveyor, however, the panel was not detected (ON) at either
the XY-table panel speed
Remedy: Check that both the XY-table panel speed reduction sensor and the panel arrival check sensor
are functioning properly a
nd confirm the panel status.
------------------------------
Code: 15040341
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: The panel passed through the XY-table panel speed reduction sensor, however, it was not
detected at the panel arrival c
heck sensor (X0AF) within the specified time limit.
Remedy: Check that the panel arrival check sensor is functioning properly and confirm the panel status.
------------------------------
Code: 15040342
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: An attempt was made to unload the board from the main-conveyor however, the XY-table panel
speed reduction sensor (X0AE
) or the panel arrival check sensor (X0AF) did not deactivate (OFF) within the specified time limit.
Remedy: Check that both the XY-table panel speed reduction sensor and the panel arrival check sensor
are functioning properl
------------------------------
Code: 15040343
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: An attempt was made to transfer a panel from the main-conveyor, however, the out-conveyor
unload panel sensor (X0CB) di
d not activate (ON) within the specified time.
Remedy: Check that the out-conveyor panel arrival sensor is functioning properly and confirm the panel
status.
------------------------------
第 1130 页
Code: 15040344
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: While waiting for the next panel, either the XY-table panel speed reduction sensor (X0AE) or the
XY-table panel arrival
sensor (X0AF) detected a panel.
While waiting for a signal from the next machine, either the XY-table panel speed reduction sensor, (X0AE)
and the panel arrival
check sensor (X0AF) was deactivated (OFF).
Remedy: Check that both the XY-table panel speed reduction sensor and the panel arrival check sensor
are functioning properl
------------------------------
Code: 15040345
Display: Main-conveyor panel loading error
Used by: CP-752E
Cause: When a panel is detected on the conveyor, the conveyor loads the panel.
If a panel is not detected on the conveyor the conveyor attempts to unload the panel.
Remedy: Check that the XY-table panel speed reduction and panel arrival sensors are functioning
properly.
------------------------------
Code: 15040346
Display: Main-conveyor Stopper Error
Used by: CP-752E
Cause: One of the following errors has occurred:
The machine output the "lower stopper" signal, however the XY-table stopper lower end sensor (X0AA) did
not activate (ON).
Both the XY-table stopper upper end sensor (X0AA), and the XY-table lower end sensor (X0A9) did not
activate (ON) within the spe
cified time limit.
Both the XY-table stopper upper end sensor (X0AA), and the XY-table lower end sensor (X0A9) did not
deactivate (OFF) within the
specified time limit.
Remedy: Check that the stopper is functioning properly, if the error continues. Check that both of the
sensors带幨X0AA, X0A9带幩ar
e functioning properly.
------------------------------
Code: 15040347
Display: Main-conveyor Panel conveyance Error
Used by: CP-752E
Cause: The XY-table panel arrival sensor (X0AF) was activated before the XY-table panel speed reduction
sensor (X0AE).
Remedy: Check that the main-conveyor panel speed reduction sensor is functioning properly and confirm
the panel status.
------------------------------
Code: 15040348
Display: Panel Set Error
Used by: CP-732E, CP-742ME, CP-742E
Cause: There is not the pallet on the XY-table in the position indicated.
Remedy: Lower the Z-axis to its lower limit position and then clear the in-carrier clamper related error.
Set the pallet on the XY-table in the position indicated.
第 1131 页