Code: 1207E?1F Display: "SCU?(ICM,PMC?) Error Code:********" (QP2) "Void Found in Flux" (QP2) Used by: QP242 Cause: The machine stopped because a void was detected in manual void detection mode. (valu…

100%1 / 5282
Code: 1207E?19
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PMC Device Reqest Logic Err" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There was a logic error in a PMC device request.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?1A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nozzle Change Sta Pos'g NG" (QP2)
Used by: QP242
Cause: There is an error in the nozzle change station upper and lower limits.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the nozzle change station. Make sure that the
upper and lower end sensors are functioning normally.
------------------------------
Code: 1207E?1B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nozzle Change Sta Pos'g NG" (QP2)
Used by: QP242
Cause: Reject conveyor operation error (positioning timeout).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure the positioning sensor on the reject conveyor is functioning normally.
------------------------------
Code: 1207E?1C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Therml Break Trip;Rjct Conv" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Reject conveyor operation error (thermal relay tripped).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Reset the thermal relay.
------------------------------
Code: 1207E?1D
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Reject Conveyor Full" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The reject conveyor is full.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the rejected parts from the reject conveyor. Make sure that the reject conveyor full
check sensor is functioning normally.
------------------------------
Code: 1207E?1E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nzl-Changer and Shutter Err" (QP2)
Used by: QP242
Cause: Nozzle changer/shutter operation error (timeout).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that nothing is interfering with the nozzle change shutter. Make sure that the shutter
open and close limit sensors are functioning normally.
------------------------------
第 819 页
Code: 1207E?1F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Void Found in Flux" (QP2)
Used by: QP242
Cause: The machine stopped because a void was detected in manual void detection mode.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, then execute the [AIR OUT] command.
------------------------------
Code: 1207E?20
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Flux Tank Empty" (QP2)
Used by: QP242
Cause: The flux tank has become empty. (The flux surface sensor has turned on.)
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, then fill the flux tank.
------------------------------
Code: 1207E?21
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nzl Head Jointed Index Unit" (QP2)
Used by: QP242
Cause: The nozzle head cannot be lowered because it is joined to an index unit.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?22
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Automatic tape cutter error" (QP2)
Used by: QP242
Cause: The automatic tape cutter operation timed out.(QP2,QP3)
(value replacing "?" is module number; error code appears in place of asterisks)(QP2)
Remedy: Use the I/O commands to check the action of the cutter and the retract confirmation
sensor.(QP2)
Check the status (cable connections, air supply) of the PFU/MFU side displayed in the parameter. If the
problem is hardware related, restart the machine.(QP3)
------------------------------
Code: 1207E?23
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"No Tray;Last Tray Rejected" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There is no tray. (The last tray of a tray stacker has been ejected.)
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, then supply tray components.
------------------------------
Code: 1207E?24
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray Rejection Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Tray ejection timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the STU and the tray ejection unit for problems.
------------------------------
第 820 页
Code: 1207E?25
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray Rejection Error" (QP2,QP2,NP3)
Used by: QP242,QP201,QP202,QP203,QP2,NP3
Cause: Tray ejection error (tray passage confirmation error).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether the ejected tray has gotten caught on something. Make sure the tray ejection
check sensor is functioning normally.
------------------------------
Code: 1207E?26
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Setting Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Board setting error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Set the hole in the board on the reference pin. Make sure that the board setting check sensor is
functioning normally.
------------------------------
Code: 1207E?27
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Clamp/Unclamp Timeout" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Board transport error (board clamp/unclamp timeout).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the board elevator. Make sure the board elevator
upper and lower limit sensors are functioning normally.
------------------------------
Code: 1207E?28
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Stpper Up/dwn Timeout" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Board transport error (board stopper up/down timeout).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the board stopper. Make sure the board stopper
upper and lower limit sensors are functioning normally.
------------------------------
Code: 1207E?29
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nzl Cyl Fwd/Rtrct Timeout" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Nozzle index cylinder forward/retract timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?2A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nzl Chngr Up/Dwn Timeout" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Nozzle select station up/down timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check whether something is interfering with the nozzle select station. Make sure the nozzle