FUJI错误代码查询.pdf - 第1124页

Display: Cycle Alarm STOPPER(IP,IP2) Stopper ascent error!(NP2,QP3) Used by: IP1,IP2,NP132,NP133,NP2,QP3 Cause: Stopper cylinder alarm. Remedy: Adjust the advance and retract positions of the stopper cylinder. ----------…

100%1 / 5282
Used by: GSP2,GSP3,IP1,IP2,NP132,NP133,NP2,QP3
Cause: The board lifter could not clamp or unclamp within the preset time limit.
Remedy: Check to see whether or not there is something interfering with the movement of the clamp.
Adjust the board lifter. Adjust the board lifter's upper and lower limit position.
------------------------------
Code: 15040305
Display: Cycle Alarm PIN
Clamper NG
Used by: GL2,GL5,GL541,IP1,IP2,NP132,NP133
Cause: A reference pin cylinder alarm occurred. The board positioning pin could not enter the reference
hole.
Remedy: Adjust the reference pin cylinder's advance and retract movement. If the pin enters the
reference hole and this message still occurs, check to see that the pin sensor dog moves into the sensor.
------------------------------
Code: 15040306
Display: CHECK FEEDER
Used by: CP3
Cause: The board feeder cylinder could not advance to the arrival position within the preset time.
Remedy: Remove any interfering objects.
------------------------------
Code: 15040307
Display: CHECK TABLE
Lifter Up/Down Error
Used by: CP3
Cause: The table could not raise or lower itself within the preset limits. Something is interfering with the
movement of the XY table.
Remedy: Remove all obstacles to board movement.
------------------------------
Code: 15040308
Display: CHECK JAW
Used by: CP3
Cause: The board feeding pin could not raise or lower itself within the preset time.
Remedy: Remove any obstacles to board movement.
------------------------------
Code: 15040309
Display: TABLE BASE NG
Used by: CP3
Cause: The table base did not move up or down correctly.
Remedy: Check that no parts or garbage is sitting under the parts table. Check IN2-30 TABLE BASE
DWD and IN2-31 TABLE BASE DWN at the I/O display. Also, turn OUT2-2 TABLE BASE DWN on and off
to check the sensor (CP3).
------------------------------
Code: 1504030A
Display: Cycle Alarm Lifter
Lifter
Used by: GL2,GL5,GL541,GSP2,GSP3
Cause: The board lifter could not clamp or unclamp within the preset time limit.
Remedy: Check to see whether or not there is something interfering with the movement of the clamp.
Adjust the board lifter. Adjust the board lifter's upper and lower limit position.
------------------------------
Code: 1504030B
第 1123 页
Display: Cycle Alarm STOPPER(IP,IP2)
Stopper ascent error!(NP2,QP3)
Used by: IP1,IP2,NP132,NP133,NP2,QP3
Cause: Stopper cylinder alarm.
Remedy: Adjust the advance and retract positions of the stopper cylinder.
------------------------------
Code: 1504030C
Display: Cycle Alarm LOADER NOTCH
Used by: GL2,GL5,GL541,IP1,IP2
Cause: Loader notch cylinder alarm.
Remedy: Adjust the advance and retract positions of the loader notch cylinder.
------------------------------
Code: 1504030D
Display: Cycle Alarm PCB_planer L or R
Used by:
Cause: The board pusher could not operate within the set time limit.
Remedy: Check that the movement of the board pusher is not being interfered with.
------------------------------
Code: 1504030E
Display: Cycle Alarm Lifter U or D
Used by: GSP2,GSP3,GSP5,GP2,GP3,GP551,GP6
Cause: The board lifter could not operate within the set time limit.
Remedy: Check that the movement of the board lifter is not being interfered with.
------------------------------
Code: 1504030F
Display: TABLE UWD NG
Used by: CP3
Cause: The XY table could not raise itself.
Remedy: Check that there is nothing interfering with the XY table's guide rail and the in or out-conveyor.
At the I/O display, toggle OUT1-18 TABLE UWD and OUT1-19 TABLE DWD on and off, and check IN2-5
FEEDER FWD.
------------------------------
Code: 15040310
Display: TABLE DWD NG
Used by: CP3
Cause: The XY table could not lower itself.
Remedy: Check that there is nothing interfering with the XY table's guide rail and the in or out-conveyor.
At the I/O display, toggle OUT1-18 TABLE UWD and OUT1-19 TABLE DWD on and off, and check IN2-5
FEEDER FWD.
------------------------------
Code: 15040311
Display: FEEDER FWD NG
Used by: CP3
Cause: The board loader cylinder could not advance.
Remedy: Check that there is nothing interfering with the board loaderls ability to move. At the I/O
display, toggle OUT1-16 FEEDER FWD and OUT1-17 FEEDER BWD on and off, and check IN2-5 FEEDER
FWD.
------------------------------
Code: 15040312
Display: FEEDER FWD NG
Used by: CP3
第 1124 页
Cause: The board loader cylinder could not retract.
Remedy: Check that there is nothing interfering with the board loaderls ability to move. At the I/O
display, toggle OUT1-16 FEEDER FWD and OUT1-17 FEEDER BWD on and off, and check IN2-5 FEEDER
FWD.
------------------------------
Code: 15040313
Display: Feeding Pin DWD NG
Used by: CP3
Cause: The board loader lever could not lower itself.
Remedy: Check the cylinder that raises and lowers this lever. Check the path of the lever for any objects
that might interfere with its movement. At the I/O display, toggle OUT1-14 FEEDING PIN DW and OUT1-
15 FEEDING PIN UP on and off and check IN2-3 FEEDING PIN DW.
------------------------------
Code: 15040314
Display: Feeding Pin UWD NG
Used by: CP3
Cause: The board loader lever could not raise itself.
Remedy: Check the cylinder that raises and lowers this lever. Check the path of the lever for any objects
that might interfere with its movement. At the I/O display, toggle OUT1-14 FEEDING PIN DW and OUT1-
15 FEEDING PIN UP on and off and check IN2-3 FEEDING PIN DW.
------------------------------
Code: 15040315
Display: CHECK XY TABLE CLUTCH
Used by: CP3
Cause: The XY table conveyor movement clutch could not advance or retract.
Remedy: At the I/O display, toggle OUT 2-25 TABLE_CL_ON on and off and check IN5-21
TABLE_CLUTCH.
------------------------------
Code: 15040316
Display: CHECK XY TABLE STOPPER
Used by: CP3
Cause: The XY table stopper could not raise or lower itself in the preset time limit.
Remedy: Check that there is no board stuck at the XY table. At the I/O display, toggle OUT2-27
T_STOPPER_OFF on and off, and check IN5-20 OUT_STOPPER_SW.
------------------------------
Code: 15040317
Display: 电路板搬运错误 MAIN
电路板载入异常(NP2,QP3)
Used by: IP1,NP2,QP3,GPX,NXTP
Cause: 虽然从载入侧搬运轨道上送出了电路板,但是主搬运轨道的电路板到达传感器在规定时间内没有变成电路板
到达的状态。
Remedy: 请检查是否有卡在搬运轨道上的电路板。
如果不打开前门进行有无电路板的确认,就不能解除错误。(GPX)
<img src="$LKEY_ERRIMG_MC$/15040317.PNG">
------------------------------
Code: 15040318
Display: PCB unloading error!(NP2,QP3)
Used by: NP2,QP3
Cause: The board was supposed to be unloaded from the main conveyor but the board did not reach the
board arrival sensor within the specified time.
Remedy: Check that the board is not stuck on the conveyor.
第 1125 页