Display: Used by: Cause: A lead pitch on the right side of the part is too narrow. The final two digits indicate the lead number. Remedy: Check the part. Check the direction of part supply. Check the entries in Part data…
Used by:
Cause: A lead on the upper side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D128F??
Display:
Used by:
Cause: A lead on the upper side of the part is too short. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1290??
Display:
Used by:
Cause: A lead pitch on the left side of the part is too wide. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1291??
Display:
Used by:
Cause: A lead pitch on the left side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1292??
Display:
Used by:
Cause: A lead pitch on the lower side of the part is too wide. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1293??
Display:
Used by:
Cause: A lead pitch on the lower side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1294??
Display:
Used by:
Cause: A lead pitch on the right side of the part is too wide. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1295??
第 1429 页
Display:
Used by:
Cause: A lead pitch on the right side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1296??
Display:
Used by:
Cause: A lead pitch on the upper side of the part is too wide. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1297??
Display:
Used by:
Cause: A lead pitch on the upper side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D12A0??
Display:
Used by:
Cause: A lead width on the left side of the part is too wide. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D12A1??
Display:
Used by:
Cause: A lead width on the left side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D12A2??
Display:
Used by:
Cause: A lead width on the lower side of the part is too wide. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D12A3??
Display:
Used by:
Cause: A lead width on the lower side of the part is too narrow. The final two digits indicate the lead
number.
第 1430 页
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D12A4??
Display:
Used by:
Cause: A lead width on the right side of the part is too wide. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D12A5??
Display:
Used by:
Cause: A lead width on the right side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D12A6??
Display:
Used by:
Cause: A lead width on the upper side of the part is too wide. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D12A7??
Display:
Used by:
Cause: A lead width on the upper side of the part is too narrow. The final two digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D12B0??
Display:
Used by:
Cause: There is a lead where there ought not to be one on the left side of the part. The final two digits
indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D12B1??
Display:
Used by:
Cause: There is no lead where there ought to be one on the left side of the part. The final two digits
indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device