Code: 12070?AD Display: "ICM(PMC?,SCU?) Error Code:********" (QP2) "Wrong Axis Bit Data Specifd" (QP2) PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP203,QP132 Cause: The specified axis…
Code: 12070?A8
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Transd Prog Larger Than Siz" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The size of the program transmitted to the PMC was larger than that specified by the DWNPRG
command.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMC. If the problem is recurring, issues such as a
faulty production program or PMC control board may be the cause.
The maximum number of sequences per production program is 5000, and the maximum number of
sequences for a PLM (PM), including mark sequences is 1000.
------------------------------
Code: 12070?AA
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Packet Number" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Incorrect packet number.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?AB
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong HEXB Data" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Incorrect HEXB data.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?AC
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong HEXW Data" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Incorrect HEXW data.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
第 746 页
Code: 12070?AD
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Axis Bit Data Specifd" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The specified axis bit data was incorrect.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?B0
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Request Inspite of No HT" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A request was issued even though no handy terminal is connected.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?B1
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Impossible to Specify Seq" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A global sequence that has already been mounted cannot be specified.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?B2
Display: PM?? ERROR Code:********
Used by: QP132
Cause: Not supported by the QP1.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?B3
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Not Supported by QP2" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Not supported by the QP2.
(value replacing "?" is module number; error code appears in place of asterisks)
第 747 页
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 12070?B4
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Seq No. for Change" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An incorrect change sequence number was specified by an N_CHNG command.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Specify the proper sequence.
------------------------------
Code: 12070?B5
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"SN Specified w/o Prg in f/g" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An N_CHNG command was executed even though there is no program in the foreground.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?B6
Display: PM?? ERROR Code:********
"Nozzle size setting error"
Used by: QP132
Cause: The nozzle size designated at the device data was not found at the NAT data.
(value replacing "??" is module number)(QP132)
Remedy: Designate a correct nozzle size.
------------------------------
Code: 12070?B8
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Nozzle Change Error" (QP2)
Used by: QP242
Cause: The machine failed to execute a nozzle change for change a single nozzle.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, return the head nozzle and nozzles at the nozzle station to their normal
states, and restart the machine.
------------------------------
Code: 12070?B9
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Nozzle Number" (QP2)
Used by: QP242
Cause: An incorrect nozzle number was specified.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Specify a nozzle number from 1 to 4 for an index nozzle, or from 1 to 7 for a single nozzle.
------------------------------
Code: 12070?BA
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)