Remedy: This error should not occur under normal conditions. ------------------------------ Code: 12070?B4 Display: "ICM(PMC?,SCU?) Error Code:********" (QP2) "Wrong Seq No. for Change" (QP2) PM?? ERR…
Code: 12070?AD
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Axis Bit Data Specifd" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The specified axis bit data was incorrect.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?B0
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Request Inspite of No HT" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A request was issued even though no handy terminal is connected.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?B1
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Impossible to Specify Seq" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A global sequence that has already been mounted cannot be specified.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?B2
Display: PM?? ERROR Code:********
Used by: QP132
Cause: Not supported by the QP1.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?B3
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Not Supported by QP2" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Not supported by the QP2.
(value replacing "?" is module number; error code appears in place of asterisks)
第 747 页
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 12070?B4
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Seq No. for Change" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An incorrect change sequence number was specified by an N_CHNG command.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Specify the proper sequence.
------------------------------
Code: 12070?B5
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"SN Specified w/o Prg in f/g" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: An N_CHNG command was executed even though there is no program in the foreground.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
------------------------------
Code: 12070?B6
Display: PM?? ERROR Code:********
"Nozzle size setting error"
Used by: QP132
Cause: The nozzle size designated at the device data was not found at the NAT data.
(value replacing "??" is module number)(QP132)
Remedy: Designate a correct nozzle size.
------------------------------
Code: 12070?B8
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Nozzle Change Error" (QP2)
Used by: QP242
Cause: The machine failed to execute a nozzle change for change a single nozzle.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Press the RESET switch, return the head nozzle and nozzles at the nozzle station to their normal
states, and restart the machine.
------------------------------
Code: 12070?B9
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Nozzle Number" (QP2)
Used by: QP242
Cause: An incorrect nozzle number was specified.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Specify a nozzle number from 1 to 4 for an index nozzle, or from 1 to 7 for a single nozzle.
------------------------------
Code: 12070?BA
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
第 748 页
"Nzl Name Not Found in Prop" (QP2)
Used by: QP242
Cause: The nozzle name in question could not be found in the Proper data.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check how the nozzle name is specified in the Part data, and register the same nozzle in the
Proper data.
------------------------------
Code: 12070?BB
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Nzl Size Not Found in Prop" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242
Cause: The nozzle in question could not be found in the Proper data.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the nozzle size specified in the Part data, and register a matching nozzle in the Proper
data.
------------------------------
Code: 12070?BF
Display: PM?? ERROR Code: ******** (QP132)
"Device check status error Device Check not complete."(QP132)
Used by: QP132
Cause: The status of a part (s) is not correct.
Automatic operation cannot be started because the status of one or some of the parts necessary for this
production program is not "OK".
("PM??" indicates the module number (QP-132).)
("********" indicates the error code.)
Remedy: Re-execute automatic operation after using the device check to change the status of the part(s)
to "OK".
------------------------------
Code: 12070?C0
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Sequence Data" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: There was an error in the sequence data.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Recheck the program's sequence data, then retransmit the program from the host computer.
------------------------------
Code: 12070?C1
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Wrong Prog Data Requested" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The requested program data was incorrect.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the production program and press the RESET button to clear the error, or restart the
machine. If the problem occurs again, use a reset-start to transmit the control software to the PMC. If the
problem is recurring, issues such as a faulty production program or PMC control board may be the cause.