FUJI错误代码查询.pdf - 第1176页
Cause: The camera Proper data has not been set. Camera Proper data has not undergone training. A section of the mark training data has been overwritten. Use the SAVE command to make a copy of the hard disk and use this t…
Code: 1C190000
Display: 1C190000
Used by:
Cause: There was an image acquisition failure using the line scan camera.
(Direction change was too fast.)
Remedy: Check the wiring and the scanning speed.
------------------------------
Code: 1C190001
Display: 1C190001
Used by:
Cause: The specified data is out of range. (Bad argument)
Remedy: Make sure that portions of the part image do not extend off the screen. Check the dimensions of
the part in part data.
------------------------------
Code: 1C200001
Display:
Used by:
Cause: The model window is too close to edge of the field.
Remedy: Change the program so that the model is seen in the center of the field.
------------------------------
Code: 1C200002
Display:
Used by:
Cause: The image has insufficient intensity variations (i.e. zero) within the model window. There must be
some contrast between the foreground and background.
Remedy: Select another area or image from which to make the model.
------------------------------
Code: 1C230007
Display: 1C230007
Used by:
Cause: The image was not acquired by the line scan camera. The movement speed of the part being
vision processed was too fast.
Remedy: Reduce the movement speed of the part in question when the image is being acquired.
------------------------------
Code: 1C230008
Display: 1C230008
Used by:
Cause: The image was not acquired by the line scan camera. The movement of the part being vision
processed stopped during image acquisition.
Remedy: Machine operation halted while the image was being acquired. Rectify the cause of this
stoppage and then carry out vision processing again.
------------------------------
Code: 1C310005
Display:
Used by:
Cause: This code occurs during camera Proper data measurements. The image is too dark.
Remedy: Slightly increase the camera gain and re-measure the Proper data.
------------------------------
Code: 1C310010
Display:
Used by:
第 1175 页
Cause: The camera Proper data has not been set. Camera Proper data has not undergone training. A
section of the mark training data has been overwritten. Use the SAVE command to make a copy of the
hard disk and use this to see whether there has been corrupted data.
Remedy: Re-measure the camera Proper data. Change the data which is different at the terminal. If
booting up from the ROM card, the part of the system which is overwritten will not start.
------------------------------
Code: 1C310011
Display:
Used by:
Cause: During calibration, a contradiction occurred. There is a contradiction with the Proper data being
used. When there are many programs in the machine, and these programs use different nozzle sizes or
cameras but the Part data files bear the same name, these file GDDUs are downloaded and saved. When
using the relevant device description, the machine will only use the last file downloaded. Therefore, when
production starts, the wide field camera is being used when the data calls for a narrow field camera, or
vice versa, and this error occurs. Alternately, if the nozzle sizes differ, error 1C410011 occurs.
Remedy: This error generally does not occur. Delete all programs from the machine and transmit only
that program which is needed.
------------------------------
Code: 1C310013
Display:
Used by:
Cause: During calibration, a movement command contradiction occurred.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C310015
Display:
Used by:
Cause: During calibration, a movement command contradiction occurred.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C310016
Display:
Used by:
Cause: During calibration, a movement command contradiction occurred.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C310017
Display:
Used by:
Cause: During calibration, a movement command contradiction occurred.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C310018
Display:
Used by:
Cause: During calibration, a movement command contradiction occurred.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C310019
Display:
Used by:
第 1176 页
Cause: Calibration was already being carried out.
Remedy: If this error occurs often, contact Fuji.
------------------------------
Code: 1C410004
Display:
Used by:
Cause: A logical error occurred. This error code may occur during device training or inspection.
Remedy: If this error occurs often, contact Fuji and be prepared to give as many details as possible.
------------------------------
Code: 1C410100
Display:
Used by:
Cause: There is no element. There is no description of the element in the device description. This error
may occur during device training.
Remedy: Check the device description. Enter a correct element description.
When using GDG, check the contents of Part data.
PD. computer_vision_no
PD. direction
PD. body_size_x,y
PD. lead_length_x,y
PD. lead_pitch
PD. lead_width
PD. lead_quality_0_3
PD. lead_information
------------------------------
Code: 1C410101
Display:
Used by:
Cause: Device segments have no edges that can be inspected. This error may occur during device
training.
Remedy: Check the device description. Enter a correct edge description.
When using e1-e4 polarity GDG, check the contents of Part data.
PD. computer_vision_no
PD. direction
PD. body_size_x,y
PD. lead_length_x,y
PD. lead_pitch
PD. lead_width
PD. lead_information
------------------------------
Code: 1C410102
Display:
Used by:
Cause: There is a mistake in the segment ID.
Remedy: Check the segment ID in the device description. Enter a correct segment ID description. When
using GDG, check the contents of of Part data.
PD. computer_vision_no
PD. direction
PD. body_size_x,y
PD. lead_length_x,y
PD. lead_pitch
第 1177 页