Display: "UNIT", "NOZZLE" machine-type "BLOCK" format error. Used by: Cause: "UNIT", "NOZZLE" in the specified production program was read and a format error was detected…

100%1 / 5282
Used by:
Cause: The nozzle data file referred to in the specified production program was read and a format error
was detected in the machine-type "BLOCK" in "UNIT", "NOZZLE". This report is made when the nozzle
data and the production program are in different files, the nozzle data referred to in the program is
required at the machine and the above error is detected.
Remedy: Check the setting for the machine-type "BLOCK" in "UNIT", "NOZZLE" in the nozzle data file
referred to in the production program.
------------------------------
Code: 51??1520
Display: No "UNIT", "NOZZLE" or "UNIT", "NOZZLE" was not found at the correct place.
Used by:
Cause: "UNIT", "NOZZLE" was not found in the specified production program or "UNIT", "NOZZLE" does
not follow the correct unit. This report is made when the nozzle data and the production program are in
the same file and the above error is detected.
Remedy: Check the setting for "UNIT", "NOZZLE" in the production program. Alternatively, check the
setting for the "UNIT" line prior to "UNIT", "NOZZLE".
------------------------------
Code: 51??1521
Display: No "BLOCK" in "UNIT", "NOZZLE".
Used by:
Cause: No "BLOCK" was found in "UNIT", "NOZZLE" in the specified production program. This report is
made when the nozzle data and the production program are in the same file and the above error is
detected. When downloading, the nozzle data takes its default values.
Remedy: Check the setting for "UNIT", "NOZZLE" in the production program.
------------------------------
Code: 51??1522
Display: No "UNIT", "NOZZLE" - "BLOCK", "HEADER".
Used by:
Cause: "BLOCK", "HEADER-" was not found in "UNIT", "NOZZLE" in the specified production program.
This report is made when the nozzle data and the production program are in the same file and the above
error is detected.
Remedy: Check the setting for "UNIT", "NOZZLE" - "BLOCK", "HEADER-" in the production program.
------------------------------
Code: 51??1523
Display: No machine-type "BLOCK" in "UNIT", "NOZZLE".
Used by:
Cause: The machine-type block was not found in "UNIT", "NOZZLE" in the specified production program.
This report is made when the nozzle data and the production program are in the same file and the above
error is detected. When downloading, the nozzle data takes its default values.
Remedy: Check the setting for the machine-type "BLOCK" in "UNIT", "NOZZLE" in the production
program.
------------------------------
Code: 51??1524
Display: "UNIT", "NOZZLE" - "BLOCK", "HEADER-" format error.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a format error was detected
in "BLOCK", "HEADER-". This report is made when the nozzle data and the production program are in the
same file and the above error is detected.
Remedy: Check the setting for "UNIT", "NOZZLE" - "BLOCK", "HEADER" in the production program.
------------------------------
Code: 51??1525
第 2231 页
Display: "UNIT", "NOZZLE" machine-type "BLOCK" format error.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a format error was detected
in the machine-type "BLOCK". This report is made when the nozzle data and the production program are
in the same file and the above error is detected.
Remedy: Check the setting for machine-type "BLOCK" in "UNIT", "NOZZLE" in the production program.
------------------------------
Code: 51??1530
Display: No item definition line for machine-type "BLOCK" in "UNIT", "NOZZLE".
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and the machine-type "BLOCK"
item definition line was not found.
Remedy: Check the setting for the item definition line for the machine-type "BLOCK" in the production
program's "UNIT", "NOZZLE".
------------------------------
Code: 51??1531
Display: "GCCNN" item not defined.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a description for "GCCNN" in
the item declaration line in the machine-type "BLOCK" was not found.
Remedy: Check the setting for "GCCNN" in the item declaration line for the machine-type "BLOCK" in
"UNIT", "NOZZLE" in the production program. "GCCNN" is a mandatory item.
------------------------------
Code: 51??1532
Display: "GNAMN"item not defined.
Used by:
Cause: "UNIT", "NOZZLE" in the specified production program was read and a description for "GNAMN"
in the item declaration line in the machine-type "BLOCK" was not found.
Remedy: Check the setting for "GNAMN" in the item declaration line for the machine-type "BLOCK" in
"UNIT", "NOZZLE" in the production program. "GNAMN" is a mandatory item.
------------------------------
Code: 51??1550
Display: There is "UNIT", "NOZZLE".
Used by:
Cause: There is a "UNIT", "NOZZLE" entry in the specified production program even though "UNIT",
"NOZZLE" was specified as being separate. At downloading, the "UNIT", "NOZZLE" entry in the program is
ignored.
Remedy: Check the "UNIT", "NOZZLE" setting in the production program and the "FILESTRUCT" setting in
"UNIT", "STRUCT".
------------------------------
Code: 51??1551
Display: "UNIT", "NOZZLE" is repeated.
Used by:
Cause: "UNIT", "NOZZLE" is repeated in the production program. When downloading, the first "UNIT",
"NOZZLE" is valid.
Remedy: Check the setting for "UNIT", "NOZZLE" in the production program.
------------------------------
Code: 51??1552
Display: Cannot find nozzle file setting line.
Used by:
Cause: The line for setting the nozzle file at "GNAN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in the
第 2232 页
specified production program has been omitted. When downloading, the nozzle data takes its default
values.
Remedy: Check the setting for "GNAN" in the production program.
------------------------------
Code: 51??1553
Display: Multiple nozzle file setting lines.
Used by:
Cause: There are multiple setting lines at "GNAN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in the
specified production program. When downloading, the final line is taken to be the valid one.
Remedy: Check the setting for "GNAN" in the production program.
------------------------------
Code: 51??1554
Display: Nozzle file name omitted.
Used by:
Cause: At the "GNAN" line in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD" in the specified production
program, the nozzle file setting is "" or it has been omitted. When downloading, the nozzle data takes its
default values.
Remedy: Check the setting for "GNAN" in the production program.
------------------------------
Code: 51??1555
Display: Setting for nozzle file name is too long.
Used by:
Cause: The nozzle file setting which is entered at "GNAN" in "UNIT", "PROGRAM" - "BLOCK", "PGHEAD"
in the specified production program is too long. The file name is abbreviated to its maximum length when
downloaded.
Remedy: Check the "GNAN" setting in the production program.
------------------------------
Code: 51??1560
Display: Data value in "GCCNN" is out of range.
Used by:
Cause: The data in the "GCCNN" item in the machine-type "BLOCK" in nozzle data is out of range. When
downloading, the corresponding data line is ignored.
Remedy: Check the setting for the "GCCNN" item in the machine-type "BLOCK".
------------------------------
Code: 51??1561
Display: Data value in"GNAMN"is out of range.
Used by:
Cause: The data in the "GNAMN" item in the machine-type "BLOCK" in nozzle data is out of range. When
downloading, the corresponding data line is ignored.
Remedy: Check the setting for the "GNAMN" item in the machine-type "BLOCK".
------------------------------
Code: 51??1600
Display: No part data file.
Used by:
Cause: The part data file which is referred to in the specified production program was not found. This
report is made when the part data and the production program are in different files and the above error is
detected.
Remedy: Check the setting for "GUTPDN" in "BLOCK", "DEVICE+" in the production program.
Furthermore, check that the file is in the part data directory.
------------------------------
Code: 51??1601