FUJI错误代码查询.pdf - 第192页
------------------------------ Code: 11074145 Display: Used by: IP2 Cause: Overtravel T+ NG Remedy: Move the appropriate part of the machine away from the overtravel sensor. ------------------------------ Code: 11074146 …
Cause:
Remedy:
------------------------------
Code: 11074100
Display:
Used by: IP2
Cause: The MTU [EMERGENCY STOP] button has been pressed.
Remedy: Cancel the MTU [EMERGENCY STOP] button.
------------------------------
Code: 11074110
Display:
Used by: IP2
Cause: A servo alarm has occurred.
Remedy: Check that the load on each servo axis is not too high.
------------------------------
Code: 11074120
Display:
Used by: IP2
Cause: A safety door is open.
Remedy: Close all safety doors.
------------------------------
Code: 11074130
Display:
Used by: IP2
Cause: A cycle alarm is occurring.
Remedy: A command to move was made, but the arrival check sensor did not turn on within the preset
time.
------------------------------
Code: 11074141
Display:
Used by: IP2
Cause: Overtravel X+ alarm.
Remedy: Move the overtravel sensor out of the overtravel position.
------------------------------
Code: 11074142
Display:
Used by: IP2
Cause: Overtravel X- alarm.
Remedy: Move the overtravel sensor out of the overtravel position.
------------------------------
Code: 11074143
Display:
Used by: IP2
Cause: Overtravel Y+ alarm.
Remedy: Move the overtravel sensor out of the overtravel position.
------------------------------
Code: 11074144
Display:
Used by: IP2
Cause: There is overtravel in the -Y axis.
Remedy: Operate the machine with the overtravel sensor removed.
第 191 页
------------------------------
Code: 11074145
Display:
Used by: IP2
Cause: Overtravel T+ NG
Remedy: Move the appropriate part of the machine away from the overtravel sensor.
------------------------------
Code: 11074146
Display:
Used by: IP2
Cause: Overtravel T- NG
Remedy: Move the appropriate part of the machine away from the overtravel sensor.
------------------------------
Code: 11074150
Display:
Used by: IP2
Cause: The 200V power supply was not on.
Remedy: Turn on the 200V power supply.
------------------------------
Code: 11074200
Display:
Used by: IP2
Cause: MTU is in OFF_LINE mode.
Remedy: Put MTU into ON_LINE mode.
------------------------------
Code: 11074201
Display:
Used by: IP2
Cause: MTU is in ON_LINE mode.
Remedy: Put MTU into OFF_LINE mode.
------------------------------
Code: 11074210
Display:
Used by:
Cause: Proper data could not be transmitted to the MTU.
Remedy: Retransmit Proper data.
------------------------------
Code: 11074220
Display:
Used by: IP2
Cause: Zero setting was not properly finished.
Remedy: Re-perform zero setting.
------------------------------
Code: 11074230
Display:
Used by: IP2
Cause: The specified tray number is out of range.
Remedy: Check the tray specifications.
------------------------------
Code: 11074240
Display:
第 192 页
Used by: IP2
Cause: There are no parts in the specified tray.
Remedy: Resupply the tray with parts.
------------------------------
Code: 11074250
Display:
Used by:
Cause: There is no tray.
Remedy: Supply a new tray.
------------------------------
Code: 11074260
Display:
Used by:
Cause: The tray was not ejected.
Remedy: Eject the tray.
------------------------------
Code: 11074270
Display:
Used by: IP2
Cause: The SY axis is not in the safety position.
Remedy: Move the SY axis into the safety position.
------------------------------
Code: 11074280
Display:
Used by: IP2
Cause: Machine can not go into ON_LINE while inching.
Remedy: Wait until after inching is finished.
------------------------------
Code: 11074290
Display:
Used by: IP2
Cause: The carrier and nozzle are full.
Remedy: Remove parts from the carrier and nozzle.
------------------------------
Code: 110742A0
Display:
Used by: IP2
Cause: Parts request command error (not P, I or S).
Remedy: None.
------------------------------
Code: 110742B0
Display:
Used by: IP2
Cause: The specified X position is out of range.
Remedy: None.
------------------------------
Code: 110742B1
Display:
Used by: IP2
Cause: The specified Y position is out of range.
Remedy: None.
第 193 页