FUJI错误代码查询.pdf - 第1894页

Cause: The temporary file defining the half-fixed (HFIX) parts could not be created. Remedy: Re-execute the function. If it still doesn't work, re-boot MCS. ------------------------------ Code: 21006037 Display: HFI…

100%1 / 5282
Display: Machine Type Table read error
Used by:
Cause: The Machine Type table could not be read.
Remedy: Re-install the software.
------------------------------
Code: 2100602F
Display: set device data after FIX
Used by:
Cause: Unplaced devices were run through the separator after the fixed devices. There is no fixed device
sequence for the specified set device in the permanent set table.
Remedy: This is a warning. It is not an error message.
------------------------------
Code: 21006030
Display: separate frame open error
Used by:
Cause: The separate frame could not be opened.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 21006031
Display: can't get queue pointer "getqp"
Used by:
Cause: A system error has occurred.
Remedy: Re-boot MCS.
------------------------------
Code: 21006032
Display: can't dequeue "deque"
Used by:
Cause: A system error has occurred.
Remedy: Re-boot MCS.
------------------------------
Code: 21006033
Display: can't queue "queing"
Used by:
Cause: A system error has occurred.
Remedy: Re-boot MCS.
------------------------------
Code: 21006034
Display: HFIX file open error
Used by:
Cause: The temporary file defining the half-fixed (HFIX) parts could not be opened.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 21006035
Display: HFIX file read error
Used by:
Cause: The temporary file defining the half-fixed (HFIX) parts could not be read.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 21006036
Display: can't create HFIX file
Used by:
第 1893 页
Cause: The temporary file defining the half-fixed (HFIX) parts could not be created.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 21006037
Display: HFIX file write error
Used by:
Cause: Data could not be written to the temporary file defining the half-fixed (HFIX) parts.
Remedy: Contact Fuji.
------------------------------
Code: 21006038
Display: separate frame write error
Used by:
Cause: Data could not be written to the separate frame.
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 21006039
Display: Part Data file not found
Used by:
Cause: The required Part Data does not exist.
Remedy: Make sure that the Part Data referred to by the source program has been stored.
------------------------------
Code: 2100603A
Display: Part Data offset table read error
Used by:
Cause: The Part Data could not be read.
Remedy: Create an offset table file.
------------------------------
Code: 2100603B
Display: Part Data read error
Used by:
Cause: Unable to read Part data.
Remedy: Create a Part data file.
------------------------------
Code: 2100603C
Display: can't create UN_SEP reason file
Used by:
Cause: The UN_SEP file could not be created.
Remedy: If there are other UN_SEP files, delete them. If there is very little memory remaining on the hard
disk, eliminate unnecessary files or perform maintenance on the hard disk.
------------------------------
Code: 2100603D
Display: UN_SEreason file write error
Used by:
Cause: The UN_SEP reason file could not be written to.
Remedy: If there is very little memory remaining on the hard disk, eliminate unnecessary files or perform
maintenance on the hard disk.
------------------------------
Code: 2100603E
Display: can't create separate frame
Used by:
Cause: The separate frame could not be created.
第 1894 页
Remedy: Re-execute the function. If it still doesn't work, re-boot MCS.
------------------------------
Code: 2100603F
Display: source program file open error
Used by:
Cause: The source program file could not be opened.
Remedy: Create a source program file.
------------------------------
Code: 21006040
Display: M/C not defined in Sep_data block of Part Data
Used by:
Cause: One of the machine types being separated is not registered in the Part Data.
Remedy: Register the machine type in the Sep_data block of the Part Data.
------------------------------
Code: 21006041
Display: no entry cartridge in Machine Type Table
Used by:
Cause: The machine type is incompatible.
Remedy: Upgrade the software so that a compatible version is being used.
------------------------------
Code: 21006042
Display: separate frame full
Used by:
Cause: Not enough free memory space remains to set the separate frame.
Remedy: Check the sep_data heading of Part data for the appropriate device.
------------------------------
Code: 21006043
Display: Device_type incorrect in Part Data
Used by:
Cause: Incorrect device data exists in Part data.
Remedy: Check the package_data block in Part data.
------------------------------
Code: 21006044
Display: manual separation cancelled
Used by:
Cause: Manual separation has been cancelled. The UN_SEP file was overwritten because there are no
slots on which to set parts.
Remedy: Check the devices.
------------------------------
Code: 21006045
Display: select UN_SEP M/C, manual separate
Used by:
Cause: No separate frame exists, so data was written to the UN_SEP file.
Remedy: Correct the source program.
------------------------------
Code: 21006046
Display: no machine eligible for separation found
Used by:
Cause: The Separator could not find an eligible machine to which a part could be assigned.
Remedy: Correct the line configuration or the source program.
------------------------------
第 1895 页