FUJI错误代码查询.pdf - 第664页

------------------------------ Code: 12066C05 Display: RADDS error Used by: NP2,QP3 Cause: RADDS not connected. Remedy: RADDS failed to start. Reset the part power supply. ------------------------------ Code: 12066C06 Di…

100%1 / 5282
Cause: The die cannot be picked becasue there is no die pick information.
Remedy: Remove the die using the die removal command.
------------------------------
Code: 12066B08
Display: RADDS error
Machine type: QP3
Used by:
Cause: Some die may still remain on RADDS.
If production is continued any remaining die will fall from the shuttle or inverter.
Remedy: Remove any remaining die from the shuttle and inverter.
Execute the following commands to delete any die references from the RADDS memory.
[RADDS Commands]
1. Close the COMMAND READY window and select "JobInfo" from the main window.
2. Select "Die in Proc" from the ID_DLG_JOB_INFO dialog box.
3. Select "Flush" from the Die in process dialog box.
------------------------------
Code: 12066B09
Display: Serial communication error
Used by: NP2,QP3
Cause: Serial communication error.
Remedy: Reset the part power supply.
------------------------------
Code: 12066C00
Display: RADDS error
Used by: NP2,QP3
Cause: Communication problem with RADDS.
Remedy: Check the RADDS connection.If the connection is OK, reset the RADDS power supply.
------------------------------
Code: 12066C01
Display: RADDS error
Used by: NP2,QP3
Cause: RADDS error stop.
Remedy: Clear the error status as instructed on the RADDS screen.
------------------------------
Code: 12066C02
Display: RADDS error
Used by: NP2,QP3
Cause: Parts out condition at RADDS.
Remedy: Supply RADDS with the required wafer.
------------------------------
Code: 12066C03
Display: RADDS error
Used by: NP2,QP3
Cause: Wafers are being supplied to RADDS.
Remedy: Supply RADDS with wafers, then close the wafer door.
------------------------------
Code: 12066C04
Display: RADDS error
Used by: NP2,QP3
Cause: Temporary stop status at RADDS.
Remedy: Clear the temporary stop status as instructed on the RADDS screen.
第 663 页
------------------------------
Code: 12066C05
Display: RADDS error
Used by: NP2,QP3
Cause: RADDS not connected.
Remedy: RADDS failed to start. Reset the part power supply.
------------------------------
Code: 12066C06
Display: RADDS error
Used by: NP2,QP3
Cause: RADDS failed to start.
Remedy: Reset the part power supply.
------------------------------
Code: 12066C07
Display: RADDS error
Used by: NP2,QP3
Cause: Wafer supply to RADDS was not completed within the prescribed period. Wafer door remains
open.
Remedy: Supply RADDS with wafers, then close the wafer door.
------------------------------
Code: 12066C08
Display: RADDS error
Used by: NP2,QP3
Cause: Unidentified part at RADDS.
Remedy: Inspect the RADDS front shuttle.
------------------------------
Code: 12066C09
Display: RADDS error
Used by: NP2,QP3
Cause: An error occurred during RADDS resetting.
Remedy: Cut the power to the RADDS and then reboot.
------------------------------
Code: 12066C0A
Display: Eject conveyor error
Used by: NP2,QP3
Cause: Feeder is present in slot specified for the reject parts conveyor.
Remedy: Check to see if a feeder is present in the slot indicated in the parameter slot display. Check to
see if a feeder is specified in the production program.
------------------------------
Code: 12066C0B
Display: Nozzle setting error
Used by: NP2,QP3
Cause: Nozzle catch sensor is ON even a although no nozzle is installed.
Remedy: Ensure if a nozzle is set in the holder.If so, reject the nozzle.
------------------------------
Code: 12066C0C
Display: STU data error
Used by: NP2,QP3
Cause: A non-STU type feeder exists within 9 slots to either side of the STU.(NP2)
A feeder has been set in the STU interference area.(QP3)
Remedy: It is prohibited to set non-STU type feeders within 9 slots at both sides of the STU. The
第 664 页
production program issues an error if a non-STU type feeder is set within 9 slots since it would intefere
with the STU.(NP2)
Feeders cannot be set inside the interference area due to the possibility of interference with the placing
head. Set all feeders outside the STU interference area.(QP3)
------------------------------
Code: 12066C0D
Display: STU error
Used by: NP2,QP3
Cause: The STU to be used with the PFU is not set to a slot specified in the production program.
Remedy: Set an STU in the slot specified in the production program.
------------------------------
Code: 12066C0E
Display: STU error
Used by: NP2,QP3
Cause: The STU to be used with the PFU is not set to a slot specified in
the production program.
Remedy: Set an STU in the slot specified in the production program.
------------------------------
Code: 12066C10
Display: Air removal failed
Used by: QP3
Cause: Stable glue dots cannot be produced due to insufficient air removal.
Remedy: Remove the air again.
------------------------------
Code: 12066C11
Display: Glue check tolerance error(QP3)
Used by: QP3
Cause: Production cannot be commenced because the glue application amount check result exceeded the
area tolerance.
Remedy: Clean the needle and screw.
------------------------------
Code: 12066C13
Display: Ion condition error
Used by: QP3
Cause: Ion emissions from the ionizer (static suppressor) are either being absorbed, or the machine
environment is unstable. Such conditions can affect the charge-neutralizing capability.
Remedy: Push [EMERGENCY STOP], verify that there is no conductive material near the ionizer, then
push [READY ON] to clear the error.
------------------------------
Code: 12066C14
Display: Pick-up position check -- interference error
Used by: QP3
Cause: The pick-up position check indicates possible interference between the head and the device.
Perform production with the pick-up position check disabled.
Remedy: Cancel the pick-up position check operation.
------------------------------
Code: 12066C15
Display: Pick-up position check -- interference area error
Used by: QP3
Cause: Device interference may occur within the interference range of the device where the pick-up
position check occurs. Perform production with the pick-up position check disabled.
第 665 页