FUJI错误代码查询.pdf - 第689页

------------------------------ Code: 12068A00 Display: Failed to clear emergency stop status. Used by: QP3,NP2 Cause: Remedy: Check the EMERGENCY STOP button and the safety door. ------------------------------ Code: 1206…

100%1 / 5282
Cause:
Remedy: Turn the TY-axis travel permit input and the tray supply input both off, and move the TY-axis to
a position where one of the inputs turns on.
------------------------------
Code: 12068801
Display: TZ-axis interlock error (no tray received).
Used by: QP3,NP2
Cause:
Remedy: Check if the drawer is triggering the tray supply sensor.
------------------------------
Code: 12068802
Display: TZ-axis interlock error (Y-axis at retract limit).
Used by: QP3,NP2
Cause:
Remedy: Check if the TY-axis is at its retract limit (TY-axis travel permit sensor on).
------------------------------
Code: 12068803
Display: TZ-axis interlock error (TY-axis at advance limit).
Used by: QP3,NP2
Cause:
Remedy: Check if the TY-axis is at its advance limit (tray pick-up sensor on).
------------------------------
Code: 12068804
Display: TZ-axis interlock error.
Used by: QP3,NP2
Cause:
Remedy: Check if the clamper cylinder open limit sensor is on.
------------------------------
Code: 12068810
Display: TY-axis interlock error (advanced).
Used by: QP3,NP2
Cause:
Remedy: Check if the tray pick-up sensor is on.
------------------------------
Code: 12068811
Display: TY-axis interlock error (retracted).
Used by: QP3,NP2
Cause:
Remedy: Check if the TY-axis retract permit sensor is on.
------------------------------
Code: 12068812
Display: TY-axis interlock error (TZ-axis position undefined).
Used by: QP3,NP2
Cause:
Remedy: Check if the TZ-axis is at tray shuttling height.
------------------------------
Code: 12068820
Display: Tray rejection error!
Used by: QP3,NP2
Cause:
Remedy: Check if the tray has been dropped during transfer to the reject position.
第 688 页
------------------------------
Code: 12068A00
Display: Failed to clear emergency stop status.
Used by: QP3,NP2
Cause:
Remedy: Check the EMERGENCY STOP button and the safety door.
------------------------------
Code: 12068A01
Display: Operation is being performed from the inching box.
Used by: QP3,NP2
Cause:
Remedy: Check if the inching input is on.
------------------------------
Code: 12068A02
Display: Failed to clear the reset status.
Used by: QP3,NP2
Cause:
Remedy: Awaiting reset command. Check if an operation instruction is being issued.
------------------------------
Code: 12068A04
Display: Resupplying parts.
Used by: QP3,NP2
Cause:
Remedy: Press the parts set switch.
------------------------------
Code: 12068A05
Display: Slot number not specified.
Used by: QP3,NP2
Cause:
Remedy: Move the extended drawer back into the magazine.
------------------------------
Code: 12068A06
Display: MTU command processing error.
Used by: QP3,NP2
Cause: While the MTU was executing a command, another command was issued bythe machine resulting
in a command processing error.
Remedy: Press READY ON to clear the error condition, and restart processing.If this type of error occurrs
frequently upgrade the MTU software.
------------------------------
Code: 12068A07
Display: Sensor measurement error.
Used by: QP3,NP2
Cause: Tray height measurement failed.
Remedy: Verify that a measurement jig is set in position and that the tray height check sensor is
functioning normally.
------------------------------
Code: 12068A08
Display: Sensor measurement data error.
Used by: QP3,NP2
Cause: Tray height measurement data error.
Remedy: Measure the height of the tray height confirmation sensor.
第 689 页
------------------------------
Code: 12068A09
Display: MTU Main power OFF.
Used by: QP3,NP2
Cause:
Remedy: The servo cannot be turned on because the main power has not been supplied to the MTU servo
amp.
------------------------------
Code: 12068A0A
Display: Emergency stop input error.
Used by: QP3,NP2
Cause: The MTU servo amplifier's emergency stop input signal has not been canceled.
Remedy: Press the [Ready ON] switch to cancel the MTU servo amplifier's emergency stop input signal.
------------------------------
Code: 12068A0B
Display: MTU controller battery alarm.
Used by: QP3,NP2
Cause: The MTU controller backup battery level is low.
Remedy: qd Replace the backup battery within two weeks from when the battery level alarm was issued.
qd Insert a new battery within five minutes of removing the original.
qd Battery type: JZSP-BA01 (Manufactured by Yaskawa)
qd Replacement procedure
(1) Turn off the power to the MTU.
(2) Remove the MTU from the main machine (QP3, NP2).
(3) Remove the battery from the MTU controller.
(4) Insert a new battery, and connect the battery connector to CN1.
------------------------------
Code: 12068A0C
Display: Tray stack height out of range.
Used by: QP3,NP2
Cause:
Remedy: Set sub-slot 1 tray stack height within 32 mm.
------------------------------
Code: 12068A0D
Display: Tray stack height out of range.
Used by: QP3,NP2
Cause:
Remedy: Set sub-slot 2 tray stack height within 32 mm.
------------------------------
Code: 12068A0E
Display: Continuous supply complete alarm.
Used by: QP3,NP2
Cause:
Remedy: Close MTU door to reset alarm.
------------------------------
Code: 12068A0F
Display: MTU Proper data SUM error.
Used by: QP3,NP2
Cause:
Remedy: Check MTU Proper data and re-enter the data at the MTU Proper data editor screen.
------------------------------
第 690 页