FUJI错误代码查询.pdf - 第751页

PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP203,QP132 Cause: There are no PMC parameters. (value replacing "?" is module number; error code appears in place of asterisks) (value replacing &quo…

100%1 / 5282
------------------------------
Code: 12070?C2
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Specified Device D Exist" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The device data in question could not be found in the program.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the production program and press the RESET button to clear the error, or restart the
machine. If the problem occurs again, use a reset-start to transmit the control software to the PMC. If the
problem is recurring, issues such as a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?C3
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Specified Block D Exist" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The block data in question could not be found in the sequence data.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the production program and press the RESET button to clear the error, or restart the
machine. If the problem occurs again, use a reset-start to transmit the control software to the PMC. If the
problem is recurring, issues such as a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?C4
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"D Number Out of Range" (QP2)(QP132)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A device number in the sequence data is outside the valid range.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Recheck the device numbers in the program data, then retransmit the program from the host
computer.
------------------------------
Code: 12070?C5
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Program Number Out of Range" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The program number is outside the valid range.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check the production program and press the RESET button to clear the error, or restart the
machine. If the problem occurs again, use a reset-start to transmit the control software to the PMC. If the
problem is recurring, issues such as a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?C6
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No PMC Parameter Exist" (QP2)
第 750 页
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: There are no PMC parameters.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Retransmit the Proper data from the host computer.
------------------------------
Code: 12070?C7
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"PMC Memory Pool Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: PMC system check error #1 (memory pool error)
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?C8
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"PMC Parameter Check Sum Err" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: PMC system check error no. 2 (parameter checksum error)
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?C9
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Prog Manage Directory Full" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The program management directory is full.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?CA
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Zero-divide error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A zero-division error has occurred.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
第 751 页
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?D0
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Machine Stop" (QP2)
PM?? ERROR Code:******** (QP132)
"Unexecutable(Error Stop)"(QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command couldn't be executed because of an emergency stop.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Cancel the PMC error, press the RESET switch, and restart the machine.
------------------------------
Code: 12070?D1
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Incomplete 0 Set" (QP2)
PM?? ERROR Code:******** (QP132)
"Zero Set Not Complete"(QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Operation is not possible because zero setting is incomplete.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET switch to cancel the error, then perform zero setting.
------------------------------
Code: 12070?D2
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Emergency Stop" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command could not be executed because emergency stop input was received.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Reset the EMERGENCY STOP switch, then press the RESET switch to cancel the error.
------------------------------
Code: 12070?D3
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Vision System Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine has stopped as the result of vision processing system error.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: If the vision processing system has not started up normally, turn the power to the machine off
and on again. Make sure that the vision processing version matches the machine's firmware version. If
an LS camera has been specified as the camera type in the Proper data, make sure that an LSO board is
mounted.
------------------------------
Code: 12070?D4
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
第 752 页