Code: 1106012D Display: Used by: Cause: The previous message remains at level 1 and a new message has been transmitted. Remedy: None. ------------------------------ Code: 1106012E Display: Used by: Cause: The previous me…

100%1 / 5282
machine is operating in on_line mode.
Remedy: None.
------------------------------
Code: 11060070
Display: Same as Code.
Used by: QP132
Cause: The program is locked. The program cannot be deleted.
Remedy: Delete the program after automatic operation has been completed.
------------------------------
Code: 11060071
Display: Same as Code.
Used by: QP132
Cause: The program is locked. The program cannot be changed.
Remedy: Change the program after automatic operation has been completed.
------------------------------
Code: 11060090
Display:
Used by:
Cause: GD transmission was cancelled because of a cancellation request.
Remedy: None.
------------------------------
Code: 11060091
Display:
Used by:
Cause: A GV command was sent when the machine was not ready to receive a GV command.
Remedy: None.
------------------------------
Code: 11060092
Display:
Used by:
Cause: The element number exceeds the number of elements in the memory.
Remedy: None.
------------------------------
Code: 110600A0
Display:
Used by:
Cause: In pallet data transmission, an applicable program could not be found.
Remedy: None.
------------------------------
Code: 110600FF
Display:
Used by:
Cause: There is no MTU for the kO command.
Remedy: None.
------------------------------
Code: 1106012C
Display:
Used by:
Cause: The previous message remains at level 0 and a new message has been transmitted.
Remedy: None.
------------------------------
第 187 页
Code: 1106012D
Display:
Used by:
Cause: The previous message remains at level 1 and a new message has been transmitted.
Remedy: None.
------------------------------
Code: 1106012E
Display:
Used by:
Cause: The previous message remains at level 2 and a new message has been transmitted.
Remedy: None.
------------------------------
Code: 1106012F
Display:
Used by:
Cause: The message was transmitted to the wrong level.
Remedy: None.
------------------------------
Code: 110601F5
Display:
Used by:
Cause: PM was sent previously.
Remedy: None.
------------------------------
Code: 110601F6
Display:
Used by:
Cause: An incorrect ID was used for PI.
Remedy: None.
------------------------------
Code: 110601F7
Display:
Used by:
Cause: The previous free flag was erased at PI transmission.
Remedy: None.
------------------------------
Code: 110601FE
Display:
Used by:
Cause: The PM module cannot be transmitted because it is masked.
Remedy: None.
------------------------------
Code: 110601FF
Display:
Used by:
Cause: There is an error in PM "D".
Remedy: None.
------------------------------
Code: 11060200
Display: 11060200
Used by:
第 188 页
Cause: There is no free flag in __unit_admin.
Remedy: None.
------------------------------
Code: 11060230
Display:
Used by:
Cause: There was transmission outside bvc specifications.
Remedy: None.
------------------------------
Code: 11060231
Display:
Used by:
Cause: Block skip data was sent before bT.
Remedy: None.
------------------------------
Code: 11060232
Display:
Used by:
Cause: bVZ was received even though bVP was not received.
Remedy: None.
------------------------------
Code: 11060401
Display:
Used by:
Cause: During partial transmission, new element data was not sent.
Remedy: Delete the program in the machine and retransmit that program.
------------------------------
Code: 11060402
Display:
Used by:
Cause: During partial transmission, the element data size was different from the previous size.
Remedy: Delete the program in the machine and retransmit that program.
------------------------------
Code: 11060403
Display:
Used by:
Cause: Data was sent even though the element name has not been sent.
Remedy: None.
------------------------------
Code: 11060404
Display:
Used by:
Cause: Element data's processing table was damaged.
Remedy: Reset-start the machine.
------------------------------
Code: 11060405
Display:
Used by:
Cause: An unusable command was sent.
Remedy: Reset-start the machine.
------------------------------
第 189 页