FUJI错误代码查询.pdf - 第2144页

Display: No nozzle is registered. Used by: Cause: No fields containing data could be found in the second row below the ["BLOCK","CONFIG+"] field or beyond in the XP-141 Nozzle Config. information file…

100%1 / 5282
Code: 2304001F
Display: Contents are not Nozzle Configuration File.
Used by:
Cause: The field "UNIT", "NZLCONF" does not exist.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040020
Display: Cannot read the file.
Used by:
Cause: An error occurred while reading the Nozzle Config. file.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040021
Display: There are no data for "XP-141" in the file.
Used by:
Cause: XP-141 Nozzle Config. information (XP141 specified in NZLCONF/HEADER/TYPE) does not exist.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040024
Display: The nozzle items "NCFNAME" or "NCFTYPE" do not exist in the file.
Used by:
Cause: The Nozzle Name and Nozzle Type cannot be obtained because either or both of the fields,
"NCFNAME" and "NCFTYPE" are missing from underneath the ["BLOCK","CONFIG+"] field in the XP-141
Nozzle Config. information file (XP141 specified in NZLCONF/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040025
Display: A syntax error occurred because the data field count does not agree with the number of nozzle
configuration items.
Used by:
Cause: The item count in the field immediately following the ["BLOCK","CONFIG+"] field in the XP-141
Nozzle Config. information file (XP141 specified in NZLCONF/HEADER/TYPE) does not match the actual
number of items in the fields below that field.
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040026
第 2143 页
Display: No nozzle is registered.
Used by:
Cause: No fields containing data could be found in the second row below the ["BLOCK","CONFIG+"] field
or beyond in the XP-141 Nozzle Config. information file (XP141 specified in NZLCONF/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Config. file. Normally, the Nozzle Config. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040027
Display: Nozzle Specification File "Fujinzl.dat" cannot be found. Specify a file?
Used by:
Cause: An attempt was made to read the Nozzle Config. File in the MCS-X default directory, but the file
could not be found. A file needs to be specified to continue.
Remedy: Select [Yes] to display the dialog for specifying a file. Select [Abort] to quit the optimizer.
------------------------------
Code: 23040028
Display: The contents of the file are empty.
Used by:
Cause: The Nozzle Spec. file size is 0 bytes.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040029
Display: Contents are not Nozzle Specifications File.
Used by:
Cause: The field "UNIT", "NZLSPEC" does not exist.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 2304002A
Display: Cannot read the file.
Used by:
Cause: An error occurred while reading the Nozzle Spec. file.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 2304002B
Display: There are no data for "XP-141" in the file.
Used by:
Cause: XP-141 Nozzle Spec. information (XP141 specified in NZLSPEC/HEADER/TYPE) does not exist.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
第 2144 页
------------------------------
Code: 2304002E
Display: The nozzle items "NCFNAME", "NCFTYPE" or "NSPNSIZD" do not exist in the file.
Used by:
Cause: The Nozzle Name, Nozzle Type, and Nozzle diameter cannot be obtained because one or more of
the fields, "NSPNAME", "NSPTYPE", and "NSPNSIZD" are missing from underneath the ["BLOCK","SPEC+"]
field in the XP-141 Nozzle Spec. information file (XP141 specified in NZLSPEC/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 2304002F
Display: A syntax error occurred because the data field count does not agree with the number of nozzle
specification items.
Used by:
Cause: The item count in the field immediately following the ["BLOCK","SPEC+"] field in the XP-141
Nozzle Spec. information file (XP141 specified in NZLSPEC/HEADER/TYPE) does not match the actual
number of items in the fields below that field.
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040030
Display: No nozzle is registered.
Used by:
Cause: No fields containing data could be found in the second row below the ["BLOCK","SPEC+"] field or
beyond in the XP-141 Nozzle Spec. information file (XP141 specified in NZLSPEC/HEADER/TYPE).
Remedy: There is a problem with the Nozzle Spec. file. Normally, the Nozzle Spec. file in the MCS-X
default directory is read automatically. Check that the file contains correct data. When starting up the
optimizer, in cases where prompted to specify a file because the default file cannot be found, check the file
contents and correct if necessary.
------------------------------
Code: 23040032
Display: The specified program file cannot be found. Search for a file?
Used by:
Cause: The specified program file name does not exist.
Remedy: Select [Yes] to display the dialog for selecting a program file to be read. Select [Abort] to cancel.
------------------------------
Code: 23040033
Display: The specified program file is not a CCIMF file (.pgo). Search for a file?
Used by:
Cause: The specified program file was not a CCIMF file.
Remedy: Select [Yes] to display the dialog for selecting a program file. Select [Abort] to cancel.
------------------------------
Code: 23040034
Display: The amount of nozzle data does not match with the nozzle data fields.
Used by:
Cause: In the Nozzle folder information file, the "NOZZLE", "XP141+" field and the item count for the
fields following that field do not match.
第 2145 页