specified for another device. This error applies to sequences 51 to 100. Remedy: Check that "TU" and "TM" in D_data in the production program match, and that the data is correct. ---------------------…

100%1 / 5282
Cause: There is a device in the TPU original device setting which is not an original device. This error
applies to devices 1 to 50.
Remedy: Set a correct "OD" value in D_data in the production program.
------------------------------
Code: 1101C071
Display:
Used by: IP3
Cause: There is a device in the TPU original device setting which is not an original device. This error
applies to devices 51 to 100.
Remedy: Set a correct "OD" value in D_data in the production program.
------------------------------
Code: 1101C072
Display:
Used by: IP3
Cause: There is a device where the TPU unit number setting is not correct. This error applies to
sequences 1 to 50.
Remedy: Set a correct "TU" value in D_data in the production program.
------------------------------
Code: 1101C073
Display:
Used by: IP3
Cause: There is a device where the TPU unit number setting is not correct. This error applies to
sequences 51 to 100.
Remedy: Set a correct "TU" value in D_data in the production program.
------------------------------
Code: 1101C074
Display:
Used by: IP3
Cause: There is a device where the TPU magazine number setting is not correct. This error applies to
sequences 1 to 50.
Remedy: Set a correct "TM" value in D_data in the production program.
------------------------------
Code: 1101C075
Display:
Used by: IP3
Cause: There is a device where the TPU magazine number setting is not correct. This error applies to
sequences 51 to 100.
Remedy: Set a correct "TM" value in D_data in the production program.
------------------------------
Code: 1101C076
Display:
Used by: IP3
Cause: There is a device where the TPU unit number and magazine number match was previously
specified for another device. This error applies to sequences 1 to 50.
Remedy: Check that "TU" and "TM" in D_data in the production program match, and that the data is
correct.
------------------------------
Code: 1101C077
Display:
Used by: IP3
Cause: There is a device where the TPU unit number and magazine number match was previously
第 74 页
specified for another device. This error applies to sequences 51 to 100.
Remedy: Check that "TU" and "TM" in D_data in the production program match, and that the data is
correct.
------------------------------
Code: 1101C078
Display:
Used by: IP3
Cause: The next device has not been specified. This error applies to device numbers 1 to 50.
Remedy: Specify a next device in "Next" in the production program.
------------------------------
Code: 1101C079
Display:
Used by:
Cause: The next device has not been specified. This error applies to device numbers 51 to 100.
Remedy: Specify a next device in "Next" in the production program.
------------------------------
Code: 1101C07A
Display:
Used by:
Cause: The next device has not been specified. This error applies to device numbers 101 to 300.
Remedy: Specify a next device in "Next" in D_Data in the production program.
------------------------------
Code: 1101C07B
Display:
Used by:
Cause: The next device has not been specified. This error applies to device numbers 301 to 500.
Remedy: Specify a next device in "Next" in D_data in the production program.
------------------------------
Code: 1101C07C
Display:
Used by: IP3
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
1 to 50.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
------------------------------
Code: 1101C07D
Display:
Used by:
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
51 to 100.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
------------------------------
Code: 1101C07E
Display:
Used by:
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
101 to 300.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
第 75 页
------------------------------
Code: 1101C07F
Display:
Used by:
Cause: There are over 30 next devices and the loop does not close. This error applies to device numbers
301 to 500.
Remedy: Change the settings in "Next" in the production program so that the loop closes within 30
devices.
------------------------------
Code: 1101C080
Display:
Used by: IP3
Cause: The next device station is not the same as that of the original device. The original device is
between device number 1 and 50.
Remedy: Specify the correct device number in "Next" in the production program's D_data.
------------------------------
Code: 1101C081
Display:
Used by:
Cause: The next device station is not the same as that of the original device. The original device is
between device number 51 and 100.
Remedy: Specify the correct device number in "Next" in the production program's D_data.
------------------------------
Code: 1101C082
Display:
Used by:
Cause: The next device station is not the same as that of the original device. The original device is
between device nunber 101 and 300.
Remedy: Specify the correct device number in "Next" in the production program's D_data.
------------------------------
Code: 1101C083
Display:
Used by:
Cause: The next device station is not the same as that of the original device. The original device is
between device number 301 and 500.
Remedy: Specify the correct device number in "Next" in the production program's D_data.
------------------------------
Code: 1101C084
Display: Same as code
Used by: GP551,GP6
Cause: A speed has been set in the final cleaning sequence.
Remedy: Be sure to set a "-1" for the final cleaning sequence.
------------------------------
Code: 1101C085
Display: Same as code
Used by: GP551,GP6
Cause: Sequence error. Verify that the sequence groups are in the order shown below.
Remedy: Re-arrange the sequences so that the groups are in the proper order,then transfer the data. The
sequence order does not apply within the same group.
Group 1: Mask mark, board fiducial mark sequence
Group 2: Inspection reference sequence
第 76 页