this sequence must be carried out using holder 1 or 4. ------------------------------ Code: 11011C01 Display: Used by: IP2 Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanari…
Display:
Used by: IP2
Cause: An attempt was made to use devices 1~3 (85~87) when an MTU is installed. When there is an
MTU on the machine, these devices cannot be used. This is to prevent possible interference between
feeders and the carrier. This message applies to sequences 1376~1500.
Remedy: Check the above mentioned sequences and alter the production program so that devices 1~3
(85~87 if there is a left MTU) are not used.
------------------------------
Code: 1101171C
Display:
Used by: IP2
Cause: An attempt was made to use devices 1~3 (85~87) when an MTU is installed. When there is an
MTU on the machine, these devices cannot be used. This is to prevent possible interference between
feeders and the carrier. This message applies to sequences 1501~1625.
Remedy: Check the above mentioned sequences and alter the production program so that devices 1~3
(85~87 if there is a left MTU) are not used.
------------------------------
Code: 1101171D
Display:
Used by: IP2
Cause: An attempt was made to use devices 1~3 (85~87) when an MTU is installed. When there is an
MTU on the machine, these devices cannot be used. This is to prevent possible interference between
feeders and the carrier. This message applies to sequences 1626~1750.
Remedy: Check the above mentioned sequences and alter the production program so that devices 1~3
(85~87 if there is a left MTU) are not used.
------------------------------
Code: 1101171E
Display:
Used by: IP2
Cause: An attempt was made to use devices 1~3 (85~87) when an MTU is installed. When there is an
MTU on the machine, these devices cannot be used. This is to prevent possible interference between
feeders and the carrier. This message applies to sequences 1751~1875.
Remedy: Check the above mentioned sequences and alter the production program so that devices 1~3
(85~87 if there is a left MTU) are not used.
------------------------------
Code: 1101171F
Display:
Used by: IP2
Cause: An attempt was made to use devices 1~3 (85~87) when an MTU is installed. When there is an
MTU on the machine, these devices cannot be used. This is to prevent possible interference between
feeders and the carrier. This message applies to sequences 1876~2000.
Remedy: Check the above mentioned sequences and alter the production program so that devices 1~3
(85~87 if there is a left MTU) are not used.
------------------------------
Code: 11011C00
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1 to 125.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
第 56 页
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C01
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 126 to 250.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C02
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 251 to 375.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C03
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 376 to 500.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C04
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 501 to 625.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C05
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 626 to 750.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C06
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
第 57 页
can only be carried out using holder 1 or 4. This error occurs in sequence 751 to 875.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C07
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 876 to 1000.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C08
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1001 to 1125.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C09
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1126 to 1250.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0A
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1251 to 1375.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0B
Display:
Used by: IP2
Cause: There are parts requiring coplanarity check on the fixed nozzles (holders 2, 3). Coplanarity check
can only be carried out using holder 1 or 4. This error occurs in sequence 1376 to 1500.
Remedy: Check that the 1.Coplanarity_check item in Coplanarity in Part data is not set to YES for this
part (even if the part does not require a coplanarity check). If this part does require a coplanarity check,
this sequence must be carried out using holder 1 or 4.
------------------------------
Code: 11011C0C