Used by: QP242,QP201,QP202,QP203 Cause: The part body sizes X and Y in part data are larger than the reject parts conveyor sizes. The first "?" represents the station number and the following "??" rep…

100%1 / 5282
Display: 11D62???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203,CP652C
Cause: (FLT, FIP3) During the device data check it was discovered that the machine does not have the
correct nozzle size to place one of the parts.
Remedy: (FLT, FIP3) Either install the required nozzle in the machine in order to place the part or change
17. Nozzle_size_max, 18. Nozzle_size_min, and 24. Nozzle name in part data's Carrying_data.
------------------------------
Code: 11D63???
Display: 11D63???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: CP652C,QP132
Cause: The backlight diameter which is specified in header data is smaller than PD's smallest backlight
diameter.
Remedy: Input the correct backlight diameter and re-transmit the program.
------------------------------
Code: 11D64???
Display: Same as code The value replacing the first "?" is the station number; the values for the remaining
"??" indicate a device number within that station. These numbers appear as hexadecimal values. When a
device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242,QP201,QP202,QP203
Cause: The vision processing camera on the indicated QP242,QP201,QP202,QP203 station cannot
execute vision processing for the indicated device.
Remedy: Mount a camera capable of performing the necessary vision processing on the indicated
QP242,QP201,QP202,QP203 station. Also, set the appropriate data for this camera in the Camera Table
of the Part data.
------------------------------
Code: 11D65???
Display: Same as Code.
Used by: QP132
Cause: A nozzle related item in part data has not been set or the value that is set is not suitable.
The first "?" of the "???" represents the module number and the following "??" represent the device within
the module. The numbers are in hexadecimal format. If the device number is greater than 256, subtract
256.
Remedy: Set the following items:Nozzle_size_max, Nozzle_size_min, Nozzle_name.
------------------------------
Code: 11D66???
Display: Same as Code.
The first "?" represents the station number and the following "??" represent the device slot within the
station. Since the device slot number is represented in hexadecimal form, subtract 256 from any number
greater than 256.
Used by: QP242,QP201,QP202,QP203
Cause: Automatic selection of the BGA parts type camera cannot be made.
Remedy: Enter the camera selection manually.
------------------------------
Code: 11D67???
Display: Same as Code.
第 284 页
Used by: QP242,QP201,QP202,QP203
Cause: The part body sizes X and Y in part data are larger than the reject parts conveyor sizes.
The first "?" represents the station number and the following "??" represent the device slot within the
station. Since the device slot number is represented in hexadecimal form, subtract 256 from any number
greater than 256.
Remedy: Change body size X, or Y, to a size smaller than the reject parts conveyor size. Alternatively, set
a size for the reject parts conveyor in Proper data large enough to accommodate the size of the part.
------------------------------
Code: 11D68???
Display: Same as Code.
Used by: QP242,QP201,QP202,QP203
Cause: The size of the scan area for the line scan camera is too large.
The first "?" represents the station number and the following "??" represent the device slot within the
station. Since the device slot number is represented in hexadecimal form, subtract 256 from any number
greater than 256.
Remedy: Reduce the values specified at part data items, "scan_area_x" and "scan_area_y" as they
currently exceed the possible maximum scan area of the line scan camera. If "0" has been specified at
these items, vision processing according to the part's sizes cannot be performed.
------------------------------
Code: 11D69???
Display: Same as code.
Used by: QP242,QP201,QP202,QP203
Cause: Placing pressure control is being used during part pick-up at a module which is not equipped
with a placing pressure control sensor.
The first "?" represents the station number and the following "??" represent the device number within the
station. The numbering is hexadecimal. For device numbers higher than 256, subtract 256.
Remedy: Pressure control is used for the part assigned to this device when it is picked up. Change the
program so that the part is picked up at a module which is equipped with a placing pressure control
sensor.
------------------------------
Code: 11D6A???
Display: Same as code.
Used by: IP-3
Cause: The camera type specified in Proper data does not match the "Lighting" and "Fst_pin_chk"
settings in part data.
The first "?" indicates the stage number, the second two "??" indicate the slot number within the stage.
This is in hexadecimal notation. Subtract 256 for values larger than 256.
Remedy: Ensure the "Lighting" and "Fst_pin_chk" settings match those shown below:
Cameras other than type 12,13 Camera type 12,13
Back_light NON, IC, IC_FIRST, IC_180, NON, IC, IC_FIRST, IC_180,
CUT CUT
Front_light_A NON, IC, IC_FIRST, IC_180, NON, IC, IC_FIRST, IC_180,
CUT, BUMP CUT
Front_light_B *** NON, IC, IC_FIRST, IC_180,
CUT, MARK, BUMP
Front_light_AB *** NON, IC, IC_FIRST, IC_180
------------------------------
Code: 11D70???
Display: 11D70???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the nozzle number in that station.
第 285 页
For nozzle numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: Cannot change to the specified nozzle.
Remedy: Do not set nozzle positions in NAT which have not been measured or do not exist.
------------------------------
Code: 11D82301
Display: Nozzle data error
Used by: CP732
Cause: Unable to distinguish the nozzles used for the parts placement.
Remedy: Verify that the nozzle name has been specified in Part Data.
------------------------------
Code: 11E000??
Display: Non
Used by: CP642,CP642M
Cause: The associated master device of the reported pair device has not been specified in device data.
The pair device number is represented by the question marks.
Remedy: Specify the master device number in sequence data.
------------------------------
Code: 11E001??
Display: Non
Used by: CP642,CP642M
Cause: The associated master device of the reported pair device has been specified more than once in
device data. The pair device number is represented by the question marks.
Remedy: Specify the master device number only once in sequence data.
------------------------------
Code: 11E002??
Display: Non
Used by: CP642,CP642M
Cause: The associated slave device of the reported pair device has not been specified in device data. The
pair device number is represented by the question marks.
Remedy: Specify the slave device number in sequence data.
------------------------------
Code: 11E003??
Display: Non
Used by: CP642,CP642M
Cause: A slave device associated with a different paired device is present in the slave device loop of the
reported pair device. The pair device number is represented by the question marks.
Remedy: Ensure that the slave device loop contains only slave devices for the associated paired device.
------------------------------
Code: 11E004??
Display: Non
Used by: CP642,CP642M
Cause: The slave device loop for the reported device has been specified more than once. The device
number is represented by the question marks.
Remedy: Ensure that there is only one slave device loop per paired device.
------------------------------
Code: 11E005??
Display: Non
Used by: CP642,CP642M
Cause: The specified paired device number of the reported device is outside the permissible range. The
device number is represented by the question marks.