error. For the QP-201E-CTL, this error is caused by a FOL carrier conveyance error (clamping / unclamping time out), package clamping / unclamping time out, package positioning error, or the detection of unremoved packag…

100%1 / 5282
Cause: The flux application/supply operation (FC-axis movement) did not start in the time allowed.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: After resetting, check the LED1 for the flux controller and if it is normal (lit), restart. If an error
(flashing) remains, check the flux controller's connector.
------------------------------
Code: 1207E?53
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"FC-axis operation" (QP2)
"completion time out" (QP2)
Used by: QP242
Cause: The flux application/supply operation (FC-axis movement) was not completed in the time allowed.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: After resetting, check the LED1 for the flux controller and if it is normal (lit), restart. If an error
(flashing) remains, check the flux controller's connector.
------------------------------
Code: 1207E?54
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"FC-axis error" (QP2)
Used by: QP242
Cause: An error has been received from the flux controller that controls the flux application/supply
operation (FC-axis movement).
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: After resetting, check the LED1 for the flux controller and if it is normal (lit), restart. If an error
(flashing) remains, check the flux controller's connector.
------------------------------
Code: 1207E?55
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Application amount max." (QP2)
"limit error" (QP2)
Used by: QP242
Cause: The flux application operation has attempted to apply an amount greater than the maximum
amount specified in Proper data.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: If this error occurs during automatic operation, check the specified application amount in the
production program. If the command sequence, [SET] -> [POSITION] -> [ETC.] -> [FLUX] -> [ETC.] ->
[APPLY TEST] was used, check the application amount with which this command was performed.
------------------------------
Code: 1207E?56
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"SCU port setting error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The Proper data check finds that the specified port number is already in use by another device.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check that the port number setting in Proper data is correct.
------------------------------
Code: 1207E?57
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Lifter Err / Package Err" (QP2)
Used by: QP201
Cause: On the QP-201E-APL, this error is caused by a FOL carrier conveyance error (clamping /
unclamping time out), part clamping / unclamping time out, part positioning error, or vacuum pads
第 829 页
error.
For the QP-201E-CTL, this error is caused by a FOL carrier conveyance error (clamping / unclamping time
out), package clamping / unclamping time out, package positioning error, or the detection of unremoved
packages.
The question marks (?) represent the module number. The asterisks (*) represent the error code.
Remedy: On the QP-201E-APL ensure that nothing is interfering with the movement of the clamping unit,
and that the raised and lowered limit sensors are functioning correctly. Check that clamping is being
performed correctly. Check that all parts are correctly positioned in the pockets. Check the action of the
vacuum pads.
On the QP-201E-CTL ensure that nothing is interfering with the movement of the clamping unit, and that
the raised and lowered limit sensors are functioning correctly. Check that clamping is being performed
correctly. Check that all packages are correctly removed from the FOL carrier.
------------------------------
Code: 1207E?58
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"No Tray / Tray Unit Full" (QP2)
Used by: QP242,QP201
Cause: (APL) There are no supply trays or, the unloading elevator is full.
(value replacing "?" is module number; error code appears in place of asterisks)
(CTL) There are no storage trays or, the unloading elevator is full.
Remedy: (APL) Load supply trays or remove the empty trays.
(CTL) Load storage trays or remove the finished trays.
------------------------------
Code: 1207E?59
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray Removal Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The tray removal operation is not complete.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Place the tray to be removed onto the unloading elevator and execute the tray unit positioning
command.
------------------------------
Code: 1207E?5A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray Supply Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The tray supply operation is not complete.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Place the empty tray onto the unloading elevator and execute the tray unit positioning
command.
------------------------------
Code: 1207E?5B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Check PLC Alarm" (QP2)
Used by: QP201,QP202,QP203
Cause: The PLC alarm has not been cleared.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the PLC alarm.
------------------------------
Code: 1207E?5C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
第 830 页
"Reset PLC failed" (QP2)
Used by: QP201,QP202,QP203
Cause: The PLC alarm cannot be cleared.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Turn the power to the machine off and on.
------------------------------
Code: 1207E?5D
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PMC and PLC are Dead Locked" (QP2)
Used by: QP201,QP202,QP203
Cause: Automatic operation cannot be started because the head and the tray are dead locked.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Move the head away from the area of interference.
------------------------------
Code: 1207E?5E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Tray unit interlock alarm" (QP2)
Used by: QP201,QP202,QP203
Cause: Automatic operation cannot be started because the tray is interlocked.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Move the head away from the area of interference.
------------------------------
Code: 1207E?5F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Pstn'g time-out (PLC Tray)" (QP2)
Used by: QP201,QP202,QP203
Cause: The tray positioning operation timed out.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the shuttle movement as well as the extend and retract position sensors. Check the rail
open/close sensor. Check the TZ-axis movement.
------------------------------
Code: 1207E?60
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PLC System Error" (QP2)
Used by: QP201,QP202,QP203
Cause: This is a sequencer servo error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Shut the power off.
------------------------------
Code: 1207E?61
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PLC Tray alarm" (QP2)
Used by: QP201,QP202,QP203
Cause: This is a sequencer operation error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check the shuttle movement as well as the extend and retract position sensors. Check the rail
open/close sensor. Check the TZ-axis movement.
------------------------------
Code: 1207E?62
Display: "ICM(PMC?,SCU?) Error Code:********"
"Empty tray pickup error"
第 831 页