FUJI错误代码查询.pdf - 第2260页
Used by: Cause: There are too many part data unit entries in the specified production program. This error occurs when the production program and part data are in one file and the part data unit entries which are not refe…
------------------------------
Code: 52??0032
Display: "UNIT", "STRUCT' entry is incorrect.
Used by:
Cause: The content of "UNIT", "STRUCT" in the specified file is incorrect.
Remedy: Check that "BLOCK", "HEADER-" is in "UNIT", "STRUCT" and that the entry for "FILETYPE",
"FILESTRUCT" is correct.
------------------------------
Code: 52??0033
Display: No entry for "FILETYPE".
Used by:
Cause: There is no entry for "FILETYPE" in the specified production program's "UNIT", "STRUCT" -
"BLOCK", "HEADER-".
Remedy: "FILETYPE" is a mandatory item.
------------------------------
Code: 52??0034
Display: No entry for "FILESTRUCT".
Used by:
Cause: There is no entry for "FILESTRUCT" in the specified production program's "UNIT", "STRUCT" -
""BLOCK", 'HEADER-".
Remedy: "FILESTRUCT" is a mandatory item.
------------------------------
Code: 52??0035
Display: Transmission image data file.
Used by:
Cause: The specified production program, partial data, Proper data and status data files are transmission
image format files.
Remedy:
------------------------------
Code: 52??0036
Display: Specified file for different machine type.
Used by:
Cause: The data in the specified file is for a different machine type. For Proper data, the machine type
specified at "MCTYPE" is checked.
Remedy: Specify the correct file or check the file's machine-type definition.
------------------------------
Code: 52??0037
Display: Machine type not defined in specified file.
Used by:
Cause: The machine type is not specified in the header data of the specified file.
Remedy: Enter the "MCTYPE" item.
------------------------------
Code: 52??0038
Display: Name not defined in specified file.
Used by:
Cause: The name is not specified in the header information of the specified file. The name for a
transmission image format production program is taken to be the same as the program name.
Remedy: Input the "NAME" item.
------------------------------
Code: 52??0039
Display: Too many part data entries.
第 2259 页
Used by:
Cause: There are too many part data unit entries in the specified production program. This error occurs
when the production program and part data are in one file and the part data unit entries which are not
referred to exceed a fixed limit.
Remedy: Delete unused part data.
------------------------------
Code: 52??0040
Display: Image data transmission revision is different.
Used by:
Cause: The specified production program is a transmission image data file but the transmission data
revision entered in the program does not match the present machine transmission revision. For this
reason the specified production program cannot be downloaded.
Remedy: A transmission image format production program can only be downloaded if the machine's
transmission revision at the time the image format file was created and the present transmission revision
are the same.
------------------------------
Code: 52??0041
Display: Image data program name is different.
Used by:
Cause: The specified partial data is a transmission image data file, but the program name recorded in the
program does not agree with the program name specified in the command line. For this reason the
specified partial data cannot be downloaded.
Remedy: Transmission image format partial data can only be downloaded to the same program as
specified at the time of image format file creation.
------------------------------
Code: 52??0050
Display: Information reported from default check/file existence check.
Used by:
Cause: Information from the default check/file existence check has been reported. This is output as
supplementary information.
Remedy: Following the supplementary information, edit the files as necessary.
------------------------------
Code: 52??0051
Display: Not production program data.
Used by:
Cause: The specified file is not a production program.
Remedy: Check the "FILETYPE" and "FILESTRUCT" settings in "UNIT", "STRUCT" - "BLOCK", "HEADER-"
in the specified file.
------------------------------
Code: 52??0052
Display: Not Proper data.
Used by:
Cause: The specified file is not Proper data.
Remedy: Check the "FILETYPE" and "FILESTRUCT" settings in "UNIT", "STRUCT" - "BLOCK", "HEADER-"
in the specified file.
------------------------------
Code: 52??0053
Display: Not status data.
Used by:
Cause: The specified file is not status data.
Remedy: Check the "FILETYPE" and "FILESTRUCT" settings in "UNIT", "STRUCT" - "BLOCK", "HEADER-"
第 2260 页
in the specified file.
------------------------------
Code: 52??0054
Display: Machine type does not use mark data.
Used by:
Cause: The specified machine type does not use mark data. This message is reported if a machine type
which does not use mark data is detected during the mark data check. In such a case the content of the
production program is not checked.
Remedy:
------------------------------
Code: 52??0055
Display: Machine type does not use nozzle data.
Used by:
Cause: The specified machine type does not use nozzle data. This message is reported if a machine type
which does not use nozzle data is detected during the nozzle data check In such a case the content of the
production program is not checked.
Remedy:
------------------------------
Code: 52??0056
Display: Machine type does not use sequence data.
Used by:
Cause: The specified machine type does not use sequence data. At present this is not reported.
Remedy:
------------------------------
Code: 52??0057
Display: Machine type does not use device data.
Used by:
Cause: The specified machine type does not use device data. This message is reported if a machine type
which does not use device data is detected during the part data check. In such a case the content of the
production program is not checked.
Remedy:
------------------------------
Code: 52??0058
Display: Machine type does not use pallet data.
Used by:
Cause: The specified machine type does not use pallet data. At present this is not reported.
Remedy:
------------------------------
Code: 52??0059
Display: This machine type does not use GSS data.
Used by:
Cause: The specified machine type does not use GSS data.Presently,this error dose not display when it
occurs.
Remedy:
------------------------------
Code: 52??0060
Display: The machine is transmitting.
Used by:
Cause: The machine with the specified nickname is presently transmitting other data.
Remedy: Execute in return on completion mode or execute again after waiting for a short time.
------------------------------