FUJI错误代码查询.pdf - 第697页

Used by: QP3,NP2 Cause: Remedy: Check if the <axis> for the MPRSRV command falls outside the 0-1 range. ------------------------------ Code: 12068CF2 Display: MPRSRV <limit> data error! Used by: QP3,NP2 Cause…

100%1 / 5282
------------------------------
Code: 12068CB1
Display: MPRORG <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRORG command falls outside the 0-2 range.
------------------------------
Code: 12068CC0
Display: MPRRMV <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRRMV command falls outside the 0-2 range.
------------------------------
Code: 12068CC1
Display: MPRRMV <data> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <data instruction> for the MPRRMV command falls outside the 0-3 range.
------------------------------
Code: 12068CD0
Display: MPRFEE <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRFEE command falls outside the 0-1 range.
------------------------------
Code: 12068CD1
Display: MPRFEE <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRFEE command falls outside the 0-2 range.
------------------------------
Code: 12068CE0
Display: MPRCNV <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRCNV command falls outside the 0-1 range.
------------------------------
Code: 12068CE1
Display: MPRCNV <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRCNV command falls outside the 0-2 range.
------------------------------
Code: 12068CF0
Display: MPRSRV <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MPRSRV command falls outside the 0-1 range.
------------------------------
Code: 12068CF1
Display: MPRSRV <axis> data error!
第 696 页
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MPRSRV command falls outside the 0-1 range.
------------------------------
Code: 12068CF2
Display: MPRSRV <limit> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <limit> for the MPRSRV command falls outside the 0-1 range.
------------------------------
Code: 12068D00
Display: MINCSP <input method> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input method> for the MINCSP command falls outside the 0-1 range.
------------------------------
Code: 12068D01
Display: MINCSP <axis> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <axis> for the MINCSP command falls outside the 0-1 range.
------------------------------
Code: 12068D02
Display: MINCSP <input data> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <input data> for the MINCSP command falls outside the 1-100 range.
------------------------------
Code: 12068D20
Display: MINTER <mode> data error!
Used by: QP3,NP2
Cause:
Remedy: Check if the <mode> for the MINTER command falls outside the 0-1 range.
------------------------------
Code: 12069001
Display: 没有进行周期自动补正的必要的吸嘴。(Diameter:***, Type:Standard)
Used by: XP142,XP242
Cause: 因为没有安装进行周期自动补正的必要的吸嘴,所以不能开始生产。
必须有Diameter:***,Type:Standard 的吸嘴。
Remedy: 请安装Diameter:***,Type:Standard 的吸嘴。
------------------------------
Code: 12069002
Display: 闪光灯亮度出错
Used by: XP142,XP242
Cause: 闪光灯的发光亮度的降低超过补正容许量。
Remedy: 请清扫闪光灯。没有改善时请更换闪光灯。
------------------------------
Code: 12069003
Display: 相机增益变化量超过公差范围。
Used by: XP142,XP242
Cause: 在自动调光中被测定的元件相机增益值的变化量过大。
第 697 页
由于误识别了光学系的污垢,所以有可能不能测定正常的相机增益值。
Remedy: 清扫光学系(棱镜、半透镜、xenon管、相机镜头)及
清扫校正尺芯片(XP142)、玻璃校正尺(XP242),
推荐执行[维修保养C]-[相机增益设定]-[基准值测定]。
------------------------------
Code: 1206A001
Display: 与中央服务器或者Profiler中央服务器的通信异常
Used by: NXTP, GPX-C
Cause: 可能未连接服务器。
Remedy: 1.请确认通信电缆的连接状态。
2.请重新启动中央服务器或者Profiler中央服务器的PC。
3.请切断机器的总电源开关后重新启动。
4.不使用TRAX功能时,请在机器功能设定中将验证设定为Off。
------------------------------
Code: 1206A002
Display: 通信数据不整合
Used by: NXTP, GPX-C
Cause: 发送数据创建、接收数据解析时检测出数据不整合。
Remedy: 1.请使中央服务器与机器的版本一致。
2.无法解决时,请切断机器的总电源开关后重新启动。
3.无法解决时,请收集发生错误时的机器跟踪数据后与本公司Support联系。
------------------------------
Code: 1206A003
Display: Fujitrax Profiler 的设定与PanelID的数有矛盾
Used by: NXTP, GPX-C
Cause: 虽然在Job上存在PanelID定位点的读取指定,但是机器功能设定的「电路板ID无ProfilerON/OFF」的设定
为ON。
Job与机器功能设定之间存在矛盾。
Remedy: 请根据Fujitrax Profiler的运用方法变更Job或者机器功能设定。
·读取PanelID定位点运用Fujitrax Profiler时,请将机器功能设定的「电路板ID无ProfilerON/OFF」设定为OFF。
·不使用PanelID定位点运用Fujitrax Profiler时,请将Job的PanelID定位点的设定变更为非读取后,重新传送Job。
有关Fujitrax Profiler的详细运用方法,请确认Fujitrax Profiler的操作手册。
------------------------------
Code: 1206A004
Display: HostInterface使用设定异常
Used by: NXTP, GPX-C
Cause: HostInterface使用(FujiTrax与上位主机的连接)设定失败。
Remedy: 有关辅助软件的机器功能设定,请确认是否已经为以下的设定。
·Profiler:ON
·电路板ID无Profiler:OFF
------------------------------
Code: 1206A005
Display: FujiTrax版本整合错误
Used by: NXTP, GPX-C
Cause: FujiTrax与机器应用程序之间间没有互换性。
Remedy: 请确认版本对应表,使用合适的版本。
<img src="$LKEY_ERRIMG_MC$/1206A005.png">
------------------------------
Code: 1206A006
Display: 为不能生产的电路板ID或者BoardID。
Used by: NXTP, GPX-C
第 698 页