FUJI错误代码查询.pdf - 第2318页

Display: Machine-type "ELEMENT" in 'UNIT", "PARTS" - "BLOCK", "ENVDT" is multiply defined. Used by: Cause: "UNIT", "PARTS" in the part data referred t…

100%1 / 5282
program was read and no data entry line was found in "BLOCK", "ELDT+".
Remedy: Check the settings for the data line in "UNIT", "PARTS" - "BLOCK", "ELDT+" in the production
program. When downloading, the default values for only one line are transmitted.
------------------------------
Code: 52??1711
Display: Too many data record lines in "UNIT", "PARTS" - "BLOCK", "ELDT+".
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and there were too many data record lines in "BLOCK", "ELDT+".
Remedy: Check the settings for the data line in "UNIT", "PARTS"-"BLOCK", "ELDT+" in the production
program. Only the valid number of lines is transmitted (starting from the top). Excess lines are ignored.
------------------------------
Code: 52??1720
Display: No "PCCTRY" item definition.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and the "PCCTRY" entry was not found in the "BLOCK", "TRAYINF+" item definition line.
Remedy: Check the setting for "PCCTRY" in the item definition line in "UNIT", "PARTS" - "BLOCK",
"TRAYINF+" in the production program. "PCCTRY" is a mandatory item. If a station number, slot number
or device number is reported as supplementary information, look for the part data name referred to in the
device line and check it.
------------------------------
Code: 52??1721
Display: "PCCTRY" data value is out of range.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and the value for the "PCCTRY" data item in "BLOCK", "TRAYINF" was out of range.
When downloading, the relevant data line is ignored.
Remedy: Check the setting for "PCCTRY" in "UNIT", "PARTS"-"BLOCK", "TRAYINF+" in the production
program.
------------------------------
Code: 52??1722
Display: "PPCTRIF" character string length is incorrect.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and the "PPCTRIF" character length in "BLOCK", "TRAYINF+" was not correct. The
correct length for the "PPCTRIF" character string is 32 characters.
Remedy: Check the setting for "PPCTRIF" in "UNIT", "PARTS" - "BLOCK", "TRAYINF+" in the production
program. When downloading, any characters which exceed the 32 character string are ignored. If the
string is shorter than 32 characters, 1s are added as padding.
------------------------------
Code: 52??1730
Display: No machine-type "ELEMENT" in "UNIT", "PARTS" - "BLOCK", "ENVDT".
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and no "ELEMENT" record was found in "BLOCK", "ENVDT" for the applicable machine
type.
Remedy: Check the setting for "ELEMENT" in "UNIT", "PARTS" - "BLOCK", "ENVDT" in the production
program.
------------------------------
Code: 52??1731
第 2317 页
Display: Machine-type "ELEMENT" in 'UNIT", "PARTS" - "BLOCK", "ENVDT" is multiply defined.
Used by:
Cause: "UNIT", "PARTS" in the part data referred to by the device data in the specified production
program was read and there were multiple records for "ELEMENT" for the applicable machine type in
"BLOCK", "ENVDT". When downloading, the lead "ELEMENT" is valid.
Remedy: Check the setting for "ELEMENT" in "UNIT", "PARTS" - "BLOCK", "ENVDT" in the production
program.
------------------------------
Code: 52??1800
Display: No specified pallet data file.
Used by:
Cause: The specified pallet data file was not found. This report is made when the program is
downloaded, the pallet data is required in the applicable machine type and the above error is detected.
Remedy: Check the setting for the pallet data file name. Furthermore, transmit the pallet data file to the
applicable directory or create it in the applicable directory.
------------------------------
Code: 52??1801
Display: Specified pallet data file in use.
Used by:
Cause: The specified pallet data file is being used. This report is made when the program is downloaded,
the pallet data is required in the applicable machine type and the above error is detected.
Remedy: Wait until the file is not being used and then re-execute.
------------------------------
Code: 52??1802
Display: No authorization for the specified pallet data file.
Used by:
Cause: There is no access authorization for the specified pallet data file. This report is made when the
program is downloaded, the pallet data is required in the applicable machine type and the above error is
detected.
Remedy:
------------------------------
Code: 52??1803
Display: Could not open pallet data file.
Used by:
Cause: The specified pallet data file could not be opened. This report is made when the program is
downloaded, the pallet data is required in the applicable machine type and the above error is detected.
Remedy:
------------------------------
Code: 52??1804
Display: No "UNIT", "STRUCT" in pallet data file.
Used by:
Cause: There is no "UNIT", "STRUCT" in the specified pallet data file. This report is made when the
program is downloaded, the pallet data is required in the applicable machine type and the above error is
detected.
Remedy: Check the setting for "UNIT", "STRUCT" in the specified pallet data file.
------------------------------
Code: 52??1805
Display: Structure error in pallet data file.
Used by:
Cause: A format error was detected in "UNIT", "STRUCT" in the specified pallet data file. This report is
made when the program is downloaded, the pallet data is required in the applicable machine type and the
第 2318 页
above error is detected.
Remedy: Check the setting for "UNIT", "STRUCT" in the specified pallet data file.
------------------------------
Code: 52??1806
Display: Not pallet data file.
Used by:
Cause: The specified pallet data file is not pallet data. This report is made when the program is
downloaded, the pallet data is required in the applicable machine type and the above error is detected.
Remedy: Check the setting for "FILETYPE", "FILESTRUCT" in "UNIT", "STRUCT" - "BLOCK", "HEADER" in
the specified pallet data file.
------------------------------
Code: 52??1807
Display: Pallet data file read error.
Used by:
Cause: A read error occurred in the specified pallet data file.
Remedy: Check the specified pallet data file.
------------------------------
Code: 52??1808
Display: No machine type definition in specified pallet data file.
Used by:
Cause: The machine type is not defined in the header information in the specified pallet data file.
Remedy: Enter the "MCTYPE" item in the specified pallet data file.
------------------------------
Code: 52??1809
Display: Pallet data file already exists.
Used by:
Cause: The specified pallet data file already exists.
Remedy:
------------------------------
Code: 52??1810
Display: No "FILETYPE" entry in pallet data file.
Used by:
Cause: There is no "FILETYPE" entry in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in the specified pallet
data file.
Remedy: "FILETYPE" is a mandatory item.
------------------------------
Code: 52??1811
Display: No "FILESTRUCT" entry in pallet data file.
Used by:
Cause: There is no "FILESTRUCT" entry in "UNIT", "STRUCT" - "BLOCK", "HEADER-" in the specified
pallet data file.
Remedy: "FILESTRUCT" is a mandatory item.
------------------------------
Code: 52??1812
Display: No "UNIT", "PALLET" in pallet data file or "UNIT", "PALLET" is not at the correct position.
Used by:
Cause: The specified pallet data file was read and "UNIT", "PALLET" was not found or "UNIT", "PALLET"
does not follow the correct unit.
Remedy: Check the setting for "UNIT", "PALLET" in the specified pallet data file. Alternatively, check the
setting for the "UNIT" line prior to "UNIT", "PALLET".
------------------------------
第 2319 页