FUJI错误代码查询.pdf - 第870页

Used by: Cause: Matching error. The motor and servo pack capacities do not match. Remedy: Check to make sure that there are no wiring problems. Contact Fuji if no abnormalities are found, because the servo amplifier coul…

100%1 / 5282
Cause: The displayed file is possibly corrupted.
Remedy: After checking the settings, reinstall the recovery media software.
Contact Fuji if this error cannot be corrected, because the hard disk could be damaged.
------------------------------
Code: 12110021
Display: Program and DLLs do not correspond.
Used by:
Cause: The current program and DLLs are not appropriate, or the installation failed.
Remedy: Reinstall the recovery media software.
Contact Fuji if this error cannot be corrected, because the hard disk could be damaged.
------------------------------
Code: 12110022
Display: SERCOS communication error.
Used by:
Cause: Communication is not performed if the digital operator was attached when communication
initialization is performed, or the SERCOS drive software version does not match.
Remedy: Disconnect the digital operator and restart the machine, or check the SERCOS drive software
version.
Contact Fuji if this error cannot be corrected, because the SERCOS drive could be damaged.
------------------------------
Code: 12110023
Display: SERCOS loop disconnected.
Used by:
Cause: The SERCOS loop is disconnected, a fiber optic connector is broken, or the fiber optics are
connected in the wrong order.
Remedy: Check the order of the fiber optic connections, and the condition of the connectors.
Contact Fuji if this error cannot be corrected, because the SERCOS drive could be damaged.
------------------------------
Code: 12110030
Display: Servo amplifier error.
Used by:
Cause: Parameters are corrupted. Servo pack EEPROM data is abnormal.
Remedy: Contact Fuji because the servo amplifier could be damaged.
------------------------------
Code: 12110031
Display: Servo amplifier error.
Used by:
Cause: Abnormal primary circuit detected. All of the detected power circuit data is abnormal.
Remedy: The power supply voltage could be fluctuating. Check the power supply voltage.
Contact Fuji if there is no abnormal power supply conditions, because the servo amplifier could
be damaged.
------------------------------
Code: 12110032
Display: Servo amplifier error.
Used by:
Cause: Abnormal parameter setting. A parameter is set outside the valid range for that parameter.
Remedy: Check all of the parameter settings for any values outside the valid range.
Contact Fuji if all of the settings are correct, because the servo amplifier could be damaged.
------------------------------
Code: 12110033
Display: Servo amplifier error.
第 869 页
Used by:
Cause: Matching error. The motor and servo pack capacities do not match.
Remedy: Check to make sure that there are no wiring problems.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110034
Display: Servo amplifier error.
Used by:
Cause: Current overload or the heat sink is too hot. The current meter has detected a surge, or the servo
pack's heat sink is too hot.
Remedy: The power supply voltage could be fluctuating. Check the voltage.
Contact Fuji if no errors are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110035
Display: Servo amplifier error.
Used by:
Cause: Regenerative error. Either the regenerative resistance wiring is disconnected, or a regenerative
transistor is damaged.
Remedy: Contact Fuji, because it is possible that the servo amplifier is damaged.
------------------------------
Code: 12110036
Display: Servo amplifier error.
Used by:
Cause: Regenerative overload. The regenerative energy is more than the regenerative resistance capacity.
Remedy: The axis rotating speed is too fast, or the regenerative resistance capacity is incorrect.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110037
Display: Servo amplifier error.
Used by:
Cause: Overvoltage. The base DC voltage is abnormally high.
Remedy: The power supply voltage could be fluctuating. Check the voltage.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110038
Display: Servo amplifier error.
Used by:
Cause: Undervoltage. The base DC voltage is too low.
Remedy: The power supply voltage could be fluctuating. Check the voltage.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110039
Display: Servo amplifier error.
Used by:
Cause: Acceleration rate. The motor is rotating abnormally high.
Remedy: The speed setting could be abnormally high. Check the parameter settings.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 1211003a
Display: Servo amplifier error.
Used by:
第 870 页
Cause: Momentary maximum torque. Operation was performed for several seconds at significantly over
the rated torque.
Remedy: Check to ensure that there is no interference or that the axis movement is not impeded. In
addition, check to ensure that none of the motor power lines are broken (U,V,W), or that there are no
shorts.
------------------------------
Code: 1211003b
Display: Servo amplifier error.
Used by:
Cause: DB overload. During dynamic braking, the rotational energy is more than the DB resistance
capacity.
Remedy: The emergency stop process could be incorrect. If this occurs frequently, contact Fuji.
------------------------------
Code: 1211003c
Display: Servo amplifier error.
Used by:
Cause: Initial resistance overload. The base power has been repeatedly turned on and off.
Remedy: Check for a short in the power line, or if the wire is broken, when this condition occurs.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 1211003d
Display: Servo amplifier error.
Used by:
Cause: Heat sink is too hot. The heat sink for the servo pack is too hot.
Remedy: Check for abnormalities in the base circuitry or in the wiring for the motor power.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 1211003e
Display: Servo amplifier error.
Used by:
Cause: Encoder feedback error. Information from the encoder is abnormal.
Remedy: Check for breaks in the encoder wiring, or for bad connections.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 1211003f
Display: Servo amplifier error.
Used by:
Cause: Erratic movement detected. Motor was out of control.
Remedy: Check the base circuit wiring, motor power wiring, and encoder wiring for any abnormalities.
Contact Fuji if no abnormalities are found, because the servo amplifier could be damaged.
------------------------------
Code: 12110040
Display: Servo amplifier error.
Used by:
Cause: Positioning deviation is too large. Positioning deviation pulse was over the set value.
Remedy: Check to ensure that the deviation setting is appropriate.
Investigate the reason for it being out of control.
------------------------------
Code: 12110041
Display: Servo amplifier error.
Used by:
第 871 页