FUJI错误代码查询.pdf - 第1106页
Cause: The quantity of boards in the in-loader (the in-lifter and the in-carrier) cannot be ascertained during flushout operation. Remedy: Turn the machine off,then on again. ------------------------------ Code: 15031008…
Display: Package unclamping error!
Used by: QP301
Cause: The ON or OFF signal for the package unclamper timed out.
Remedy: Check for interference with the package unclamper.
------------------------------
Code: 15026007
Display: Package unclamper sensor error!
Used by: QP301
Cause: Both the ON and OFF sensor of the package unclamper are on.
Remedy: Check both sensors.
------------------------------
Code: 15031001
Display:
Used by: CP5,GL5,GL541,IP3
Cause: Operation was cancelled because of an alarm from the application.
Remedy: None.
------------------------------
Code: 15031002
Display:
Used by: CP4-1,P4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: Loading position alarm.
Remedy: None.
------------------------------
Code: 15031003
Display:
Used by: CP4-1,P4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: Lifter position error
Remedy: None.
------------------------------
Code: 15031004
Display:
Used by: CP4-1,P4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,CP-752,GL5,GL541,IP3
Cause: Interlock error
Remedy: None.
------------------------------
Code: 15031005
Display: Loader ROM Error
Used by:
Cause: The board loader PLC ROM version is newer than the machine ROM version (i.e. the number of
the machine version is lower than the number of the PLC version).
Remedy: Contact Fuji.
------------------------------
Code: 15031006
Display: Brd supply number rpt error
Used by: CP643
Cause: Board quantity cannot be ascertained when loading a board from in-carrier to main conveyor.
Remedy: Turn the machine off,then on again.
------------------------------
Code: 15031007
Display: IN-loader brd rpt error
Used by: CP643
第 1105 页
Cause: The quantity of boards in the in-loader (the in-lifter and the in-carrier) cannot be ascertained
during flushout operation.
Remedy: Turn the machine off,then on again.
------------------------------
Code: 15031008
Display: IN搬运轨道的升降台上升失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: IN搬运轨道的升降台上升失败。
Remedy: IN搬运轨道的升降台未上升时,请确认通过升降台的配管是否脱离。
上升时,请确认IN升降台上升确认传感器是否正常地动作。
------------------------------
Code: 15031009
Display: IN搬运轨道的升降台下降失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: IN搬运轨道的升降台下降失败。
Remedy: 请确认IN升降台上升确认传感器是否正常地动作。请确认通过升降台的配管是否脱离。
------------------------------
Code: 1503100A
Display: MAIN搬运轨道的升降台上升失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: MAIN搬运轨道的升降台上升失败。
Remedy: MAIN搬运轨道的升降台未上升时,请确认通过升降台的配管是否脱离。
上升时,请确认MAIN升降台上升以及下降确认传感器是否正常地动作。
------------------------------
Code: 1503100B
Display: MAIN搬运轨道的升降台下降失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: MAIN搬运轨道的升降台下降失败。
Remedy: MAIN搬运轨道的升降台未下降时,请确认通过升降台的配管是否脱离。
请确认MAIN升降台上升以及下降确认传感器是否正常地动作。
------------------------------
Code: 1503100C
Display: MAIN搬运轨道的阻挡块上升失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: MAIN搬运轨道的阻挡块上升失败。
Remedy: MAIN搬运轨道的阻挡块未上升时,请确认通过升降台的配管是否脱离。
请确认阻挡块上升确认传感器是否正常地动作。
------------------------------
Code: 1503100D
Display: MAIN搬运轨道的阻挡块下降失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: MAIN搬运轨道的阻挡块下降失败。
Remedy: 请确认阻挡块上升确认传感器是否正常地动作。请确认通过阻挡块的配管是否脱离。
------------------------------
Code: 1503100E
Display: 向MAIN搬运轨道的电路板到达传感器的电路板搬运失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 向MAIN搬运轨道的电路板到达传感器的电路板搬运失败。
Remedy: 请确认电路板在搬运途中是否被钩住。
请确认MAIN到达传感器是否正常地动作
------------------------------
第 1106 页
Code: 1503100F
Display: 确认电路板通过失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 确认电路板通过失败。
Remedy: 请确认电路板在搬运途中是否被钩住。
请确认MAIN通过传感器是否正常地动作。
------------------------------
Code: 15031010
Display: 向次工序的电路板搬运失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 向次工序的电路板搬运失败。
Remedy: 请确认电路板在搬运途中是否被钩住。
请确认从次工程来的要求电路板信号是否正常地动作。
------------------------------
Code: 15031011
Display: 向MAIN搬运轨道的电路板减速传感器的电路板搬运失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 向MAIN搬运轨道的电路板减速传感器的电路板搬运失败。
Remedy: 请确认电路板在搬运途中是否被钩住。
请确认电路板减速信号是否正常地动作。
------------------------------
Code: 15031012
Display: IN搬运轨道的电路板搬运失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: IN搬运轨道的电路板搬运失败。
Remedy: 请确认电路板是否正常地运行至IN搬运轨道到达传感器。
请确认从前工程来的可以搬运电路板信号(X018:PcbAvailable)是否正常地动作。
------------------------------
Code: 15031013
Display: 搬运轨道宽度与前工序不一致。
Used by: XP142,XP242
Cause: 搬运轨道宽度与前工序不一致。
Remedy: ·请确认前工序和本机器的搬运轨道宽度。
·搬运轨道宽度没有问题时,请确认+跟踪确认传感器(X059)、以及、-跟踪确认传感器(X05A)是否正常地动
作。
·+跟踪确认传感器(X059)、以及、-跟踪确认传感器(X05A)未安装的机器上,请设定固有值「
__ConveyorFollowCheck」为"0"。
------------------------------
Code: 15031014
Display: 在IN升降台下降后IN平台电路板到达确认传感器没作出反应。
Used by: XP142,XP143,XP242,XP243
Cause: 在IN升降台下降后IN平台电路板到达确认传感器没作出反应。
Remedy: 请确认IN平台的电路板的位置是否在IN平台电路板到达确认传感器作出反应的位置。
请确认IN平台电路板到达确认传感器在正常工作。
------------------------------
Code: 15032002
Display: IN-car for/bck lmt both OFF
Used by: CP643
Cause: The in-carrier extended sensor and retracted sensor are both OFF.
Remedy: Check the in-carrier extended sensor (LX01C) and the in-carrier retracted sensor (LX01D). if the
carrier is stopped between the sensors,move the in-carrier either forward or backward.
第 1107 页