------------------------------ Code: 1D15E??? Display: Used by: Cause: The image in vision processing is not correct so operation was canceled. Remedy: Check the part. Check the direction of part supply. Check the entrie…

100%1 / 5282
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D15C3??
Display:
Used by:
Cause: A lead could not be detected on the upper side of the part. The two final digits indicate the lead
number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D15C4??
Display:
Used by:
Cause: An edge could not be detected on the left side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D15C5??
Display:
Used by:
Cause: An edge could not be detected on the lower side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D15C6??
Display:
Used by:
Cause: An edge could not be detected on the right side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D15C7??
Display:
Used by:
Cause: An edge could not be detected on the upper side of the part.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D15D000
Display:
Used by:
Cause: The part pickup slippage was too large (X direction).
Remedy: Check how the parts are being supplied.
------------------------------
Code: 1D15D080
Display:
Used by:
Cause: The part pickup slippage was too large (Y direction).
Remedy: Check how the parts are being supplied.
第 1463 页
------------------------------
Code: 1D15E???
Display:
Used by:
Cause: The image in vision processing is not correct so operation was canceled.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D15F???
Display:
Used by:
Cause: There was a logical error in the management program.
Remedy: Check Part data.
------------------------------
Code: 1D160002
Display:
Used by:
Cause: The part cannot be picked.
Remedy: Replenish the part supply.
------------------------------
Code: 1D164001
Display:
Used by:
Cause: This Vision number is unsupported.
Remedy: It is necessary to upgrade the software.
------------------------------
Code: 1D164007
Display:
Used by:
Cause: There are 2~4 leads more than set in Part data.
Remedy: Check the setting in Part data.
------------------------------
Code: 1D164009
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D16400A
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D16400B
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D16400C
第 1464 页
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D16400D
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D16400E
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D16400F
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D164010
Display:
Used by:
Cause: The lead width is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D164011
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D164012
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D164013
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the part shape, check that the part is being picked properly, and check the image taken
by vision processing.
------------------------------
Code: 1D168002
Display:
Used by: