FUJI错误代码查询.pdf - 第1456页
Display: Used by: Cause: This Computer Vision No. is not supported. Remedy: Check the Computer Vision No. in Part Data. ------------------------------ Code: 1D158110 Display: Used by: Cause: Lead_pitch (pitch between the…
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D15400E
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D15400F
Display:
Used by:
Cause: Unable to find the lead.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D154010
Display:
Used by:
Cause: The lead width is not in the acceptable range.
Remedy: Check the lead width, part shape and the image taken by vision processing.
------------------------------
Code: 1D154011
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D154012
Display:
Used by:
Cause: Unable to find the body.
Remedy: Check that the part is being picked properly, and check the part shape.
------------------------------
Code: 1D154013
Display:
Used by:
Cause: The body size is not in the acceptable range.
Remedy: Check the part shape, check that the part is being picked properly, and check the image taken
by vision processing.
------------------------------
Code: 1D158002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D158100
第 1455 页
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D158110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D158111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D158112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.
------------------------------
Code: 1D158113
Display:
Used by:
Cause: Lead_length_y in Part data has not been specified.
Remedy: Specify Lead_length_y in Part data.
------------------------------
Code: 1D158114
Display:
Used by:
Cause: Body_size_1 (body length in the X direction) in Part data has not been specified.
Remedy: Specify Body_size_1 in Part data.
------------------------------
Code: 1D158115
Display:
Used by:
Cause: Body_size_0 (body length in the Y direction) in Part data has not been specified.
Remedy: Specify Body_size_0 in Part data.
------------------------------
Code: 1D158120
Display:
Used by:
Cause: Qty_0 (the number of leads on the left side) in Part data has not been specified.
Remedy: Specify Qty_0.
------------------------------
Code: 1D158121
Display:
Used by:
Cause: Qty_1 (the number of leads on the lower side) in Part data has not been specified.
第 1456 页
Remedy: Specify Qty_1.
------------------------------
Code: 1D158122
Display:
Used by:
Cause: Qty_2 (the number of leads on the right side) in Part data has not been specified.
Remedy: Specify Qty_2.
------------------------------
Code: 1D158123
Display:
Used by:
Cause: Qty_3 (the number of leads on the upper side) in Part data has not been specified.
Remedy: Specify Qty_3.
------------------------------
Code: 1D1582??
Display:
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1583??
Display:
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1584??
Display:
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1585??
Display:
Used by:
Cause: The body is too short in the Y direction.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1588??
Display:
Used by:
Cause: A lead on the left side of the part is too long. The final two digits indicate the lead number.
Remedy: Check the part. Check the direction of part supply. Check the entries in Part data and Device
data.
------------------------------
Code: 1D1589??
Display:
第 1457 页