FUJI错误代码查询.pdf - 第455页
Cause: The laser beam was unblocked at the wrong point or was not completely blocked. Remedy: Check the positions of the sensor and the lead location. If this error occurs while the lead is being measured, check that the…
exchange the cable. If serial communication can be downloaded from the LLL board, the LLL error
conditions can be checked. Set the LLL board so that serial communication can be performed. If the LLL
board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board and a
terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must match the
LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036022
Display: Sensor 0 Synchronization Error
Used by: IP1,IP2,IP3
Cause: Communication could not be performed with L3 Sensor 0.
Remedy: Either the sensor cable is cut or is not connected. Check the sensor cable connection or
exchange the cable. If serial communication can be downloaded from the LLL board, the LLL error
conditions can be checked. Set the LLL board so that serial communication can be performed. If the LLL
board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board and a
terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must match the
LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036023
Display: Sensor 1 Synchronization Error
Used by: IP1,IP2,IP3
Cause: Communication could not be performed with L3 Sensor 1.
Remedy: Either the sensor cable is cut or is not connected. Check the sensor cable connection or
exchange the cable. If serial communication can be downloaded from the LLL board, the LLL error
conditions can be checked. Set the LLL board so that serial communication can be performed. If the LLL
board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board and a
terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must match the
LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036030
Display: Expecting FIFO Data Empty
Used by: IP1,IP2,IP3
Cause: There is a defective VME board.
Remedy: Reset-start the machine. If serial communication can be downloaded from the LLL board, the
LLL error conditions can be checked. Set the LLL board so that serial communication can be performed.
If the LLL board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board
and a terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must
match the LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036031
Display: Expecting FIFO Data Available
Used by: IP1,IP2,IP3
Cause: There is a defective VME board.
Remedy: Reset-start the machine. If serial communication can be downloaded from the LLL board, the
LLL error conditions can be checked. Set the LLL board so that serial communication can be performed.
If the LLL board's dip switch S4's 1 is set to ON, debug information can be output. Connect the LLL board
and a terminal (personal computer, etc.) via an RS232C or RS-422 cable. The terminal settings must
match the LLL board settings. In this way, if the LLL operates, one can check where the error originated.
------------------------------
Code: 12036040
Display: Expecting Beam Blocked
Used by: IP1,IP2,IP3
第 454 页
Cause: The laser beam was unblocked at the wrong point or was not completely blocked.
Remedy: Check the positions of the sensor and the lead location. If this error occurs while the lead is
being measured, check that the lead lengths set in Part data (Vision data items 10.Lead_length_x,
11.Lead_length_y) are as accurate as possible. Make the offset in Coplanarity item 4.Y_offset larger and
measure the lead.
------------------------------
Code: 12036041
Display: Expecting Beam Unblocked
Used by: IP1,IP2,IP3
Cause: The laser beam was blocked at the wrong point or was not completely unblocked.
Remedy: Check that there are no foreign particles blocking the sensor. Check that the part being
measured has leads.
------------------------------
Code: 12036042
Display: LLL:Sensor DAC Error
Used by: IP1,IP2,IP3,QP242
Cause: The LLL sensor is damaged.
Remedy: Contact Fuji.
------------------------------
Code: 12036050
Display: LLL: NPX Error
Used by: IP1,IP2,IP3,QP242
Cause: The LLL controller is damaged.
Remedy: Contact Fuji.
------------------------------
Code: 12037000
Display: Memory allocation error
Used by: CP5,GP551,GP6,QP242,QP201,QP202,QP203
Cause: An error occurred due to a lack of memory in the machine control software. This error occurred
when Fuji OS system call_test (_MALLOC) which secures a new memory block was used.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037001
Display: Memory allocation error
Used by: CP3,CP4-1,CP4-2,CP4-3
Cause: An error occurred due to a lack of memory in the machine control software. This error occurred
when Fuji OS system call_test (_GET_HEEP) which secures memory of a specified size in the global field
was used.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037002
Display: Memory allocation error
Used by:
Cause: An error occurred due to a lack of memory in the machine control software. This error occurred
when Fuji OS system call_test (_GET_MEMORY) which secures memory of a specified size in the stack
field was used.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
第 455 页
Code: 12037003
Display: Memory allocation error
Used by:
Cause: An error occurred due to a lack of memory in the machine control software. This error occurred
when Fuji OS system call_test (_GET_GLOBAL) which secures memory of a specified size in the standard
memory was used.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 12037004
Display: RB UDT creation error
Used by:
Cause: In conjunction with the internal processing of the machine software, an attempt was made to
create a robust unit data table using the _create_robust_udt() system call of the Fuji operation system.
However, table creation was not successful because of insufficient memory.
Remedy: Reboot the machine using the reset-start procedure. If operation works properly after the reset-
start then wait in this status for several minutes. Consult Fuji if nothing changes even after a reset-start
is carried out or if the same type of symptoms occur frequently.
------------------------------
Code: 1203701?
Display: RB SRV creation error
Used by: GP551,GP6
Cause: In conjunction with the internal processing of the machine software, an attempt was made to
create a robust servo driver using the _create_robust_srv() system call of the Fuji operation system.
However, servo driver creation was not successful because of insufficient memory. The last digit in the
error code indicates the number of the axis for which creation was attempted.
Remedy: Reboot the machine using the reset-start procedure. If operation works properly after the reset-
start then wait in this status for several minutes. Consult Fuji if nothing changes even after a reset-start
is carried out or if the same type of symptoms occur frequently.
------------------------------
Code: 1203710?
Display: MX100 creation error
Used by: CP4-1,CP4-2,CP4-3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GP551,GP6
Cause: An error occurred during initialization of a board or in communication with a board. This error
occurred when Fuji OS system call_create_k300() which manages board initialization was used to generate
event control blocks (ICB) for the remote I/O and the OP link. The last number in the error code indicates
the number of the board in which the error occurred. 0 indicates the first board.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 1203711?
Display: MX100 creation error
Used by: CP4-1,CP4-2,CP4-3,CP5,CP642,CP643,GL541,GP551,GP6
Cause: An error occurred in the machine control software . This error occurred when Fuji OS system
call_create_k300() which generates event control blocks (ICB) for the remote I/O and the OP link was used.
The last number in the error code indicates the number of the board in which the error occurred. 0
indicates the first board.
Remedy: Press RESET and then resume operation. If this error occurs frequently or cannot be corrected,
notify Fuji.
------------------------------
Code: 1203712?