FUJI错误代码查询.pdf - 第1077页
Used by: GL2,GL5,GSP2,GSP3,IP1 Cause: The slope of the mark in the Y direction exceeds +-10% of Size_b. Remedy: Check the CCD level and the program mark data. ------------------------------ Code: 14010062 Display: err006…
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The distance from the center to the left side of the mark exceeds +-20% of the input value.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010053
Display: err0053
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The distance from the center to the right side of the mark exceeds +-20% of the input value.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010054
Display: err0054
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The first mark detected is the same color as the mark color set with header data's Black/White
but the boundary (the borderline between the mark and the background) cannot be detected.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010055
Display: err0055
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The first mark detected is the same color as the mark color set with header data's Black/White
but the boundary (the borderline between the mark and the background) cannot be detected.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010056
Display: err0056
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The first mark detected is the same color as the mark color set with header data's Black/White
but the boundary (the borderline between the mark and the background) cannot be detected.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010057
Display: err0057
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The mark's size in the X direction (Size_a) exceeds 10% of the input value.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010058
Display: err0058
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The mark's size in the Y direction (Size_a) exceeds 10% of the input value.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010060
Display: err0060
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The slope of the mark in the X direction exceeds +-10% of Size_b.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010061
Display: err0061
第 1076 页
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The slope of the mark in the Y direction exceeds +-10% of Size_b.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010062
Display: err0062
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The width at the top (Size_b) exceeds the tolerance range (more than +-10%).
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010063
Display: err0063
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The width on the right side (Size_b) exceeds the tolerance range (more than +-10%).
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010064
Display: err0064
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: If the fiducial mark is a cross mark, the width at the top and the bottom (dimension b) exceeds
the tolerance range ( more than +-10 %). Alternatively, operation was stopped by an interrupt command.
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14010065
Display: err0065
Used by: GL2,GL5,GSP2,GSP3,IP1
Cause: The width on the left side (Size_b) exceeds the tolerance range (more than +-10%).
Remedy: Check the CCD level and the program mark data.
------------------------------
Code: 14011000
Display: 读取基准定位点出错
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 读取基准定位点出错。
Remedy: 请确认是否输入正确的定位点数据。
请确认生产程序上的坐标与实际定位点位置的坐标是否一致。
基准定位点上有污垢存在时请除去。
------------------------------
Code: 14011001
Display: 在范围检查中超过范围公差值。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 在范围检查中超过范围公差值。
Remedy: 请确认生产程序上的坐标与实际定位点位置的坐标是否一致。
在读取基准定位点时存在着错误识别的可能性。
------------------------------
Code: 14011002
Display: 在间距检查中超过间距公差值。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 在间距检查中超过间距公差值。
Remedy: 请确认生产程序上的坐标与实际定位点位置的坐标是否一致。
在读取基准定位点时存在着错误识别的可能性。
------------------------------
第 1077 页
Code: 14011003
Display: 在周期自动补正中用于测定基准定位点的影像处理失败。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 在周期自动补正中用于测定基准定位点的影像处理失败。
Remedy: 请确认基准定位点是否有污垢。
------------------------------
Code: 14011004
Display: 基准定位点产生1mm以上的偏差。请重新测定基准定位点。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 基准定位点的固有值或原点有可能偏移。
Remedy: 请重新测定基准定位点,或重新测定原点。
------------------------------
Code: 14011005
Display: 基准定位点的影像处理失败。
Used by: XP142,XP242
Cause: 基准定位点的影像处理失败。
Remedy: 请确认基准定位点是否有污垢。请确认基准定位点的固有值。
------------------------------
Code: 14011006
Display: 不能发现高精度料盘基准定位点。
Used by: XP242
Cause: 读取的料盘为高精度料盘时,定位点有污垢或距基准位置的偏移太大。
读取的料盘为标准料盘时,高精度料盘确认传感器的调整不良。
Remedy: 高精度料盘时,请确认定位点是否有污垢。。
请消除往复臂的错位。
标准料盘时,请调整高精度料盘确认传感器(X045)。
------------------------------
Code: 14011007
Display: 基准定位点的识别角度超过了容许值。
Used by: XP142,XP242
Cause: 基准定位点的识别角度超过了容许值。
Remedy: 请确认电路板的角度。
请确认基准定位点的模板。
------------------------------
Code: 14011008
Display: 单料盘基准定位点的影像处理失败。
Used by: XP142
Cause: 单料盘上的基准定位点的影像处理失败。
Remedy: 请确认是否安装了单料盘。
请确认在固有值中基准定位点的位置是否被正确地设定。
请确认定位点是否有污垢。
------------------------------
Code: 14011009
Display: 微型料盘基准定位点的影像处理失败。
Used by: XP142
Cause: 微型料盘专用托架上的基准定位点的影像处理失败。
Remedy: 请确认是否安装了微型料盘专用托架。
请确认基准定位点是否有污垢。
------------------------------
Code: 14030001
Display: er0001
第 1078 页