FUJI错误代码查询.pdf - 第718页

------------------------------ Code: 12070?17 Display: "ICM(PMC?,SCU?) Error Code:********" (QP2) "Pre-picked Part Exists" (QP2) PM?? ERROR Code:******** (QP132) Used by: QP242,QP201,QP202,QP203,QP132…

100%1 / 5282
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Data Out of Range" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command contains data outside the valid range.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?13
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Servo Driver Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A servo driver error has occurred.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12070?14
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Servo Controller Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A servo controller error has occurred.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
faulty hardware such as servo amps or servo boards may be the cause.
------------------------------
Code: 12070?15
Display: "ICM(PMC?,SCU?) Error code:********" (QP2)
"Exceeded acceptable inching range for the Q-axis" (QP2)
Used by: QP202,QP203
Cause: The acceptable inching range for the Q-axis has been exceeded.
Remedy: Correct the angle of the Q-axis by up to +-15 deg..
------------------------------
Code: 12070?16
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Manual" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command cannot be executed because the machine is operating in manual mode.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty PMC control board may be the cause.
第 717 页
------------------------------
Code: 12070?17
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Pre-picked Part Exists" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The command cannot be executed because a pre-picked part exists.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, then use commands to dump parts. If the problem
occurs again, use a reset-start to transmit the control software to the PMCs. If the problem is recurring,
issues such as a faulty PMC control board may be the cause.
------------------------------
Code: 12070?18
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Program" (QP2)
PM?? ERROR Code:******** (QP132)
"No Production Program" (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The machine did not contain the program named in the pallet ID. This error may also occur
during index operation in a mode other than automatic mode, or as the result of a QP1 firmware
malfunction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: QP1 specifications do not allow the deletion of a program as long as there is a board being
produced in the machine. This error occurs if there is a pallet in the machine when a program is forcibly
deleted by a command from a host computer, when a program is deleted by a reset start, etc. Since
production cannot be continued in such cases, either use the [SKIP] command to eject the board, or
execute flush-out operation.
------------------------------
Code: 12070?19
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Check Sum Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A checksum error has been found.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMCs. If the problem is recurring, issues such as
a faulty production program or PMC control board may be the cause.
------------------------------
Code: 12070?1A
Display: "ICM(PMC?,SCU?) Error code:********" (QP2)
"No trays" (QP2)
Used by: QP202,QP203
Cause: No part supply trays are available.
Remedy: Supply trays.
------------------------------
Code: 12070?1B
Display: "ICM(PMC?,SCU?) Error code:********" (QP2)
第 718 页
"No dummy parts" (QP2)
Used by: QP202
Cause: Run out of dummy parts.
Remedy: Resupply the dummy parts tray.
------------------------------
Code: 12070?1C
Display: "ICM(PMC?,SCU?) Error code:********" (QP2)
"Head above tray zero set not possible" (QP2)
Used by: QP202,QP203
Cause: Head is positioned above tray and may interfere with tray during zero setting.
Remedy: Move the head away from the tray using the inching keys.
------------------------------
Code: 12070?1D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Orientation Check Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The recovery limit has been reached due to orientation errors.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Correct the orientation of the parts.
------------------------------
Code: 12070?20
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Insufficient Free Memory" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The remaining free memory is insufficient.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Press the RESET button to clear the error, or restart the machine. If the problem occurs again,
use a reset-start to transmit the control software to the PMC. If the problem is recurring, issues such as a
faulty production program or PMC control board may be the cause.
The maximum number of sequences per production program is 5000, and the maximum number of
sequences for a PLM (PM), including mark sequences is 1000.
------------------------------
Code: 12070?21
Display: PM?? ERROR Code:********
"Pallet ID reading error"(QP132)
Used by: QP132
Cause: The pallet ID cannot be read. This is a pallet ID controller error. ?? indicates the module
number. **** indicates the command name in which the error occurred.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)
Remedy: Check the pallet position. Check the error code which is displayed by the ID controller LED.
------------------------------
Code: 12070?22
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Final Position NG" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The IN position is inappropriate.
(value replacing "?" is module number; error code appears in place of asterisks)
第 719 页