Cause: An out of range value was detected for "GUTSLTN" in the "BLOCK", "DEVICE+" data when "UNIT", "PROGRAM" in the specified production program was read. At present thi…
Used by:
Cause: No "GUTSTN" entry was found in the item definition line in "BLOCK", "DEVICE+" when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the "GUTSTN" setting in the item definition line in "UNIT", "PROGRAM" - "BLOCK",
"DEVICE+" in the production program. "GUTSTN" is a mandatory item.
------------------------------
Code: 51??1051
Display: No "GUTSLTN" item definition.
Used by:
Cause: No "GUTSLTN" entry was found in the item definition line in "BLOCK", "DEVICE+" when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the "GUTSLTN" setting in the item definition line in "UNIT", "PROGRAM" - "BLOCK",
"DEVICE+" in the production program. "GUTSLTN" is a mandatory item.
------------------------------
Code: 51??1052
Display: No "GUTDN" item definition.
Used by:
Cause: No "GUTDN" entry was found in the item definition line in "BLOCK", "DEVICE+" when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the "GUTDN" setting in the item definition line in "UNIT", "PROGRAM" - "BLOCK",
"DEVICE+" in the production program. "GUTDN" is a mandatory item.
------------------------------
Code: 51??1053
Display: No "GUTPDN" item definition.
Used by:
Cause: No "GUTPDN" entry was found in the item definition line in "BLOCK", "DEVICE+" when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the "GUTPDN" setting in the item definition line in "UNIT", "PROGRAM" - "BLOCK",
"DEVICE+" in the production program. "GUTPDN" is a mandatory item.
------------------------------
Code: 51??1054
Display: No compatible device data was found.
Used by:
Cause: Data for the necessary station numbers, slot numbers and device numbers was not found in the
"BLOCK", "SEQUENCE+" data when "UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Normally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line. Also check the device data references in
"UNIT", "PROGRAM" - "BLOCK", "SEQUENCE+".
------------------------------
Code: 51??1055
Display: "GUTSTN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTSTN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read. At present this error does not occur.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program.
------------------------------
Code: 51??1056
Display: "GUTSLTN" value out of range.
Used by:
第 2199 页
Cause: An out of range value was detected for "GUTSLTN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read. At present this error does not occur.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program.
------------------------------
Code: 51??1057
Display: "GUTDN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTDN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read. At present this error does not occur.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program.
------------------------------
Code: 51??1058
Display: "GUTNSTN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTNSTN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line.
------------------------------
Code: 51??1059
Display: "GUTNSLTN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTNSLTN" in the "BLOCK", "DEVICE+" data when
"UNIT", "PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line.
------------------------------
Code: 51??1060
Display: "GUTNDN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTNDN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line.
------------------------------
Code: 51??1061
Display: "GUTPDN" value out of range.
Used by:
Cause: An out of range value was detected for "GUTPDN" in the "BLOCK", "DEVICE+" data when "UNIT",
"PROGRAM" in the specified production program was read.
Remedy: Check the data setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line. "GUTPDN" is a mandatory item.
------------------------------
Code: 51??1062
Display: Part data name for "GUTPDN" is too long.
第 2200 页
Used by:
Cause: "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" data in the specified production program was read
and the "GUTPDN" part data name was too long. The file name is abbreviated to its maximum length
when downloaded.
Remedy: Check the "GUTPDN" setting for "UNIT", "PROGRAM" - "BLOCK", "DEVICE+" in the production
program. Generally the station number, slot number or device number in which the error occurred is
reported to the supplementary information line. Check this line.
------------------------------
Code: 51??1070
Display: "GSQSSLTN"value out of range.
Used by:
Cause: An out of range value was detected for"GSQSSLTN"in the"BLOCK","SEQUENCE+"data
when"UNIT","PROGRAM"in the specified production program was read.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","SEQENCE+"in the production program.
Normally the sequence number in which the error occurred is reported to the supplementary information
line. Check this line.
------------------------------
Code: 51??1071
Display: No"GUTSSLTN"item declaration.
Used by:
Cause: No"GUTSSLTN"entry was found in the item declaration line
in"BLOCK","DEVICE+"when"UNIT","PROGRAM"in the specified production program was read.
Remedy: Check the"GUTSSLTN"setting in the item declaration line in"UNIT","PROGRAM"-
"BLOCK","DEVICE+"in the production program. "GUTSSLTN"is a mandatory item.
------------------------------
Code: 51??1072
Display: "GUTSSLTN"value out of range.
Used by:
Cause: An out of range value was detected for"GUTSSLTN"in the"BLOCK","DEVICE+"data
when"UNIT","PROGRAM"in the specified production program was read. At present this error does not
occur.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","DEVICE+"in the production program.
------------------------------
Code: 51??1073
Display: "GUTNSSLT"value out of range.
Used by:
Cause: An out of range value was detected for"GUTSSLTN"in the"BLOCK","DEVICE+"data
when"UNIT","PROGRAM"in the specified production program was read.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","DEVICE+"in the production program.
Generally the stage number,slot number,sub slot number in which the error occurred is reported to the
supplementary information line.
------------------------------
Code: 51??1074
Display: Invalid combination of sub slot numbers found.
Used by:
Cause: Both a zero and a non-zero value exist for the same slot of the same stage in the specified
program.
Remedy: Check the data setting for "UNIT","PROGRAM"-"BLOCK","DEVICE+"or"UNIT","PROGRAM"-
"BLOCK","SEQUENCE+"in the production program. Generally the sequence number at which the error
occurred is reported to the supplementary information line if the problem was found in
the"SEQUENCE+"section. If the problem lies in the "DEVICE+"section,the stage number,slot number and
第 2201 页