FUJI错误代码查询.pdf - 第290页

------------------------------ Code: 12020106 Display: Plt Clear Off To PPS Error Used by: CP5 Cause: A request was made from PCM to PPS to unload pallets. The lower conveyor of the PPS was not empty. Remedy: Remove the …

100%1 / 5282
Used by: CP3,CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643,GSP2,GP2,GP3
Cause: Clear off is finished.
Remedy: None.
------------------------------
Code: 12010701
Display: 往复臂运转模式错误
Used by: NXTP
Cause: 往复臂不是运转模式
Remedy: 请将往复臂置于运转模式
------------------------------
Code: 12010702
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 12020101
Display: PCM PLC Alarm
Used by: CP5
Cause: The pallet loader control system is down.
Remedy: Contact Fuji.
------------------------------
Code: 12020102
Display: Pallet ID Read Error (FCP5)
Pallet ID could not be Read (FCP651C)
Used by: CP652C
Cause: The ID could not be read. The acquisition of the ID for the pallet on the up-elevator has failed
(FCP651C).
Remedy: Verify that there is nothing abnormal about the pallet at the stand by station. Check that the ID
read position is not misaligned (FCP651C). Replace the ID card if read errors occur frequently. If the
pallet ID card is replaced, be sure that the ID_No. is written (recorded). Refer to the Operation Manual
concerning the ID_No. write Command.
------------------------------
Code: 12020103
Display: Check PPS Error
Used by: CP5
Cause: An error occurred at the PPS.
Remedy: Check the display and remove the cause of the error.
------------------------------
Code: 12020104
Display: PPS AUTO Mode Error
Used by: CP5
Cause: A pallet movement request was sent to the PPS when PPS was not in automatic mode.
Remedy: Start the PPS automatic mode.
------------------------------
Code: 12020105
Display: Plt Clear off to PPS Error
Used by: CP5
Cause: A request was made from PCM to PPS to unload pallets. The lower conveyor of the PPS was not
empty.
Remedy: Remove the pallet from the PPS lower conveyor.
第 289 页
------------------------------
Code: 12020106
Display: Plt Clear Off To PPS Error
Used by: CP5
Cause: A request was made from PCM to PPS to unload pallets. The lower conveyor of the PPS was not
empty.
Remedy: Remove the pallet from the PPS lower conveyor.
------------------------------
Code: 12020107
Display: Check PCM R_Conveyor
Used by: CP5
Cause: An error was received from the PCM return conveyor.
Remedy: Check the PCM error display and remove the cause of the error.
------------------------------
Code: 12020108
Display:
Used by: CP5
Cause: The PCM is in manual operation, or the in and out elevator pallet arrived sensor or the pallet
arrived sensor between the out elevator and the PPS is OFF. The permission signal from the PPS to the
out elevator (with a PPS) is OFF.
Remedy: Get the PCM out of manual operation. Check the sensors.
------------------------------
Code: 12020109
Display: Desired Pallet is Not Found
Used by: CP652C
Cause: The PCM or PPS pallets were circulated and a search for the desired pallet was carried out, but
the pallet was not in the machine.
Remedy: Load the pallet to be used in production into the machine.
------------------------------
Code: 12020200
Display: TPU SEQUENCER ERROR
Used by: IP2,IP3
Cause: The digital controller is damaged or the battery is dead.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020201
Display: TPU DEVICE No. ERROR
Used by: IP2,IP3
Cause: An incorrect magazine number was specified.
Remedy: Check the production program.
------------------------------
Code: 12020202
Display: TPU CYCLE NG
Used by: IP2,IP3
Cause: The TPU cycle could not finish.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020203
Display: TPU PICK UP ERROR
Used by: IP2,IP3
Cause: The machine failed to pick parts.
第 290 页
Remedy: Execute the recovery command.
------------------------------
Code: 12020204
Display: TPU SHUTTLE ERROR
Used by: IP2,IP3
Cause: The shuttle does not work properly.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020205
Display: TPU FORMING ERROR
Used by: IP2,IP3
Cause: The cut-and-form mechanism does not work properly.
Remedy: Operate the equipment in manual operation. If it does not work normally, contact Fuji.
------------------------------
Code: 12020206
Display: TPU SUPPLY ERROR
Used by: IP2,IP3
Cause: The TPU part supplier does not work properly.
Remedy: Operate the equipment in manual operation. Also, check the supplier at the I/O board.
------------------------------
Code: 12020207
Display: TPU ORIGINAL POSITION ERROR
Used by: IP2,IP3
Cause: When the TPU was started, the shuttle or the cut-and-form mechanism was not in the original
position.
Remedy: Return these parts to the origin position in manual operation.
------------------------------
Code: 12020208
Display: TPU MANUAL MODE ERROR
Used by: IP2,IP3
Cause: The TPU is in manual operation.
Remedy: Perform production in automatic operation.
------------------------------
Code: 12020209
Display: TPU EMERGENCY
Used by: IP2,IP3
Cause: The TPU has been subject to an emergency stop.
Remedy: Release the Emergency Stop button, or check for the cause at the I/O board.
------------------------------
Code: 1202020A
Display:
Used by: IP2,IP3
Cause: A parameter was specified incorrectly during startup of the TPU.
Remedy: Check the production program.
------------------------------
Code: 1202020B
Display:
Used by: IP3
Cause: A part supply cycle could not be completed.
Remedy: Check the I/O board at the machine.
------------------------------
第 291 页