FUJI错误代码查询.pdf - 第577页

------------------------------ Code: 12056015 Display: "Sensor Logic Error Solder Pusher" Used by: GP551,GP6 Cause: The opposite sensor has not turned off even though the cylinder has reached the destination in…

100%1 / 5282
Display: "Sensor logical alarm: cleaner shift" (GP6)
Used by: GP6
Cause: The cleaner shift forward end (X07C) and retract end (X07D) sensors have either both turned on
or both turned off at the same time.
Remedy: Check the cleaner shift forward end and retract end sensors, and adjust them as necessary.
------------------------------
Code: 1205600F
Display: "M/C err Sensor SQG Holder" (GP6 w/single squeegee), "M/C err Sensor
SQG F" (front squeegee on double-squeegee GP6), "M/C err Sensor SQG R"
(rear squeegee on double-squeegee GP6)
Used by: GP6
Cause: The squeegee holder upper limit and lower limit check sensors (X070 and X071 for either a single
squeegee or squeegee F, and X078 and X079 for squeegee R) have either both turned on or both turned off
at the same time.
Remedy: Check the squeegee holder upper limit and lower limit check sensors, and adjust them as
necessary.
------------------------------
Code: 12056010
Display: "M/C err Sensor Top Cleaner Connected"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056011
Display: "Sensor Logic Error Conveyor Width Clutch"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056012
Display: "Sensor Logic Error Push Plate"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056013
Display: "M/C err Sensor Holder **(UPorDOWN)"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056014
Display: "Sensor Logic Error SQG Open/Close"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
第 576 页
------------------------------
Code: 12056015
Display: "Sensor Logic Error Solder Pusher"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056016
Display: "M/C err Sensor Cleaner Released"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056017
Display: "M/C err Sensor Clnr Head **** (Open or Close)"
Used by: GP551
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056018
Display: "Sensor Logic Error Replenish *** Wrn (BTM or TOP)"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 12056019
Display: "Sensor Logic Error Screen Clamp Top"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 1205601A
Display: "Sensor Logic Error Solder Supply UP/DN"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 1205601B
Display: "Sensor Logic Error Mask Supprt"
Used by: GP551,GP6
Cause: The opposite sensor has not turned off even though the cylinder has reached the destination
indicated by its output.
Remedy: Adjust the sensor.
------------------------------
Code: 1205601C
第 577 页
Display: "Sensor Logic Error Screen Transport Clamp"
Used by: GP6
Cause: The screen transport chuck open limit and close limit sensors (1111 and 1112) have either both
turned on or both turned off at the same time.
Remedy: Check the screen transport chuck open limit and close limit sensors, and adjust them as
necessary.
------------------------------
Code: 1205601D
Display: "Sensor Logic Error Screen Lifter"
Used by: GP6
Cause: The screen lifter upper limit and lower limit check sensors (1113 and 1114) have either both
turned on or both turned off at the same time.
Remedy: Check the screen lifter upper limit and lower limit check sensors, and adjust them as necessary.
------------------------------
Code: 1205601E
Display: "Sensor Logic Error Screen Pusher"
Used by: GP6
Cause: The screen pusher forward end and retract end check sensors (1113 and 1114) have either both
turned on or both turned off at the same time.
Remedy: Check the screen pusher forward end and retract end check sensors, and adjust them as
necessary.
------------------------------
Code: 1205601F
Display: Sensor Logic Error Camera/Lower Cleaner Pos
Used by: GP551
Cause: The origin position sensor and the proximity sensor for both the camera and lower cleaner are
simultaneously in the on condition, resulting in an error.
Remedy: Check the on/off status for the camera's retract position sensor, the lower cleaner's origin
position sensor, and the proximity sensors for both the lower cleaner and the camera.
------------------------------
Code: 12056020
Display: Sensor logic alarm Z-axis
Used by: GP551
Cause: An alarm occurred because the sensors which check that the movement of the Z-axis is in the
permissible range are not operating correctly.
Remedy: Check the operation of these sensors by ensuring the sensors behave in the following manner
when the Z-axis is moved from the loading position to the printing position.
(1) (2) (3)(4)
Y-axis interlock sensor ON OFF OFFOFF
Z-axis retract position sensor ON ON OFFOFF
Z-axis/lower cleaner interlock sensor ON ON ONOFF
(1) When the Z-axis is at the loading position.
(2) When the Z-axis is moved from the loading position to the mark read position.
(3) When the Z-axis is at the mark reading position.
(4) When the Z-axis is at the printing position.
------------------------------
Code: 12056021
Display: Lifter up1/down lmt snsr err
Used by: CP643
Cause: A logic error has occurred between the sensors that check table height
during part placement.