Code: 1503400D Display: XY-table dwn lmt sensor has not come ON Used by: CP643 Cause: The XY-table has been lowered,but the main conveyor lower limit sensor hane not turned ON. Remedy: Check the main conveyor lower limit…

100%1 / 5282
Used by: CP4-1,CP4-2,CP4-
3.CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,GSP5,GP2,GP3,GP511,GP6,IP3
Cause: The digital programmer did not reach its target position within the preset time limit.
Remedy: Undecided.
------------------------------
Code: 15034006
Display:
Used by: CP4-1,CP4-2,CP4-3.CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL5,GL541,IP3
Cause: The reference pin did not reach its target position within the preset time limit.
Remedy: Undecided.
------------------------------
Code: 15034007
Display:
Used by: CP5,GL5,GL541,IP3
Cause: The 2 level conveyor vertical movement did not reach its target position within the preset time
limit.
Remedy: Undecided.
------------------------------
Code: 15034008
Display:
Used by: CP5,GL5,GL541,IP3
Cause: The conveyor joining notch did not reach its target position within the preset time limit.
Remedy: Undecided.
------------------------------
Code: 15034009
Display: XY-table clp lmt sensor has not come ON
Used by: CP643
Cause: The XY-table has been clamped,but the main conveyor board clamp sensors hane not turned ON.
Remedy: Check the main conveyor board clamp sensors (X060,X061,X06C ).
------------------------------
Code: 1503400A
Display: XY-table unclp lmt sensor has not turned OFF
Used by: CP643
Cause: The XY-table has been clamped,but the main conveyor board unclamp sensors hane not turned
OFF.
Remedy: Check the main conveyor board unclamp sensors (X062,X063,X06D ).
------------------------------
Code: 1503400B
Display: XY-table unclp lmt sensor has not come ON
Used by: CP643
Cause: The XY-table has been unclamped,but the main conveyor board unclamp sensors hane not
turned ON.
Remedy: Check the main conveyor board unclamp sensors (X062,X063,X06D ).
------------------------------
Code: 1503400C
Display: XY-table clp lmt sensor has not turned OFF
Used by: CP643
Cause: The XY-table has been unclamped,but the main conveyor board clamp sensors hane not turned
OFF.
Remedy: Check the main conveyor board clamp sensors (X060,X061,X06C ).
------------------------------
第 1110 页
Code: 1503400D
Display: XY-table dwn lmt sensor has not come ON
Used by: CP643
Cause: The XY-table has been lowered,but the main conveyor lower limit sensor
hane not turned ON.
Remedy: Check the main conveyor lower limit sensors (X067).
------------------------------
Code: 1503400E
Display: Interlock alarm:I_CRRY
In-carrier not clamped
Used by: CP643
Cause: The in-carrier extended limit claws closed sensors (LX042,LX043) have not turned ON when the
XY-table is at height ZL-7 mm while loading or unloading a board.
Remedy: Check the in-carrier extended limit claws closed sensors (LX042,LX043).
------------------------------
Code: 1503400F
Display: Interlock alarm:O_CRRY
Out-carrier not clamped
Used by: CP643
Cause: The out-carrier extended limit claws closed sensors (LX048,LX049) have
not turned ON when the XY-table is at height ZL-7 mm while loading or unloading
a board.
Remedy: Check the out-carrier extended limit claws closed sensors (LX048,LX049).
------------------------------
Code: 15034010
Display: XY-table dwn lmt sensor has not come OFF
Used by: CP643
Cause: The XY-table was raised,but the main conveyor lower limit sensor hane not turned OFF.
Remedy: Check the main conveyor lower limit sensors (X067).
------------------------------
Code: 15034011
Display: Middle loading pos. error. Check sensor and Prop. data.
Used by: CP643
Cause: The main conveyor attempted to move over the middle loading position, but the middle loading
position sensor was off, or the Z-axis was outside the Proper data range.
Remedy: The axis cannot move if the middle loading position sensor is on and the Z-axis is not within the
range specified in Proper data (+50 pulse/-100 pulse). Check the position of the sensor, and the Proper
data settings.
------------------------------
Code: 15040001
Display: Check Loader
Used by: IP2
Cause: The board detection sensor between the main, in or out conveyors was activated.
Remedy: Check the position of the board on the loader. If the conveyor is caught in the Y axis, return it
to its correct position.
------------------------------
Code: 15040002
Display: Cycle Alarm PCB Loading
Used by:
Cause: A board loading alarm occurred.
Remedy: Check the board which is being loaded.
第 1111 页
------------------------------
Code: 15040101
Display: Emergency Stop
Used by:
Cause: The emergency stop button was pressed (when using peripherals this message can occur if the
safety door has been opened).
Remedy: After resetting the emergency stop button (or closing the safety door), press the reset button.
------------------------------
Code: 15040102
Display:
Used by:
Cause: The board was supposed to be unloaded from the MCID but the board did not reach the board
arrival sensor within the specified time.
Remedy: Check that the board is not stuck on the conveyor.
------------------------------
Code: 15040103
Display: "PCB Stopper Error MCID"
Used by:
Cause: MCID stopper cycle error. The stopper ON or OFF check sensor did not turn on within three
seconds (on the QP2) after an instruction to raise or lower the board stopper was issued.
Remedy: Check whether stopper operation is being prevented by an obstacle (such as a board). If so,
remove the obstacle. If not, perform an I/O check to make sure the stopper ON and OFF check sensors
are functioning normally.
------------------------------
Code: 15040201
Display: IN CONVEYOR NG
Used by: IP1
Cause: While in automatic operation, a board stuck out of the in-conveyor (IP1).
Remedy: Check the board on the in-conveyor. Alternately, adjust the in-conveyor board arrival sensor
and the in-conveyor board pass sensor.
------------------------------
Code: 15040202
Display: Cycle Alarm Loading Error
Loading Error
Used by: GL2,GSP2,GSP3,NP132,NP133
Cause: A board got caught while being loaded onto the in-conveyor, causing this alarm. After a board
was unloaded from the in-conveyor, it did not arrive at the main conveyor within the preset time limit.
When MCID is being used, this code can occur after the MCID conveyor and the in-conveyor (GSP). When
a board was sent to the main conveyor from the in-conveyor, it was stopped en route. Alternately, the
borad detection sensors at the in-conveyor or the main conveyor are not working correctly (the in sensor is
on or the main sensor is off).
Remedy: Check that the board is not stuck on the conveyor. If the machine thinks that the board has
been moved from its correct position, remove that board.
------------------------------
Code: 15040203
Display: CHECK INB STOPPER
Used by: CP3,QP242,NP132,NP133
Cause: The in-conveyor in B stopper cannot raise or lower itself within the preset time.
Remedy: Check that there is no board stuck between the in B conveyor and the main conveyor. Use the
I/O to check OUT2-26 B_STOPPER_OFF by toggling OUT2-26 B_STOPPER_OFF by toggling this on and
off, and check the input conditions at IN5-19 IN_STOPPER_SW.