Used by: Cause: The machine has determined that imaging conditions are not correct. Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check the image acquisition condition…

100%1 / 5282
Cause: No leads could be found on the upper side.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D34C4??
Display: Same as code.
Used by:
Cause: The left edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D34C5??
Display: Same as code.
Used by:
Cause: The lower edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D34C6??
Display: Same as code.
Used by:
Cause: The right edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D34C7??
Display: Same as code.
Used by:
Cause: The upper edge of the part's body could not be found.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions.
------------------------------
Code: 1D34D000
Display: Same as code.
Used by:
Cause: The pickup position error (in the X direction) is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D34D080
Display: Same as code.
Used by:
Cause: The pickup position error (in the Y direction) is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D34D100
Display: Same as code.
Used by:
Cause: The part's inclination is excessive.
Remedy: Check the manner in which parts are supplied.
------------------------------
Code: 1D34E???
Display: Same as code.
第 1666 页
Used by:
Cause: The machine has determined that imaging conditions are not correct.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data. Check
the image acquisition conditions. In particular, check for soiling of the nozzle, and make sure that the
CCD level is correct.
------------------------------
Code: 1D34F???
Display: Same as code.
Used by:
Cause: There is a logical error in the processing program. The part cannot be processed due to an
excessive discrepancy between the Part data and the actual values for the part.
Remedy: Check the Part data.
------------------------------
Code: 1D350002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is too large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D354006
Display: Same as code.
Used by:
Cause: This error occurs when the image quality is unstable (due to soiling of the nozzle or the part),
when the part shape is inappropriate (e.g. when there are protrusions or concavities), or when there is a
large discrepancy between Part data values and the actual values for the part.
Remedy: Check for soiling of the nozzle or the part. Make sure that the correct part is being processed.
------------------------------
Code: 1D354041
Display: Same as code.
Used by:
Cause: This error occurs when the image quality is unstable (due to soiling of the nozzle or the part),
when the part shape is inappropriate (e.g. when there are protrusions or concavities), or when there is a
large discrepancy between Part data values and the actual values for the part.
Remedy: Check for soiling of the nozzle or the part. Make sure that the correct part is being processed.
------------------------------
Code: 1D354042
Display: Same as code.
Used by:
Cause: The body size indicated by the Part data is much larger than the actual size.
Remedy: Check the Part data. Also, check for soiling of the nozzle or the part. Make sure that the correct
part is being processed.
------------------------------
Code: 1D354043
Display: Same as code.
Used by:
Cause: The body size indicated by the Part data is much smaller than the actual size. This error could
also occur if the part supply direction is different from that recorded in the Part data.
Remedy: Check the Part data. Also, check for soiling of the nozzle or the part. Make sure that the correct
part is being processed.
第 1667 页
------------------------------
Code: 1D354044
Display: Same as code.
Used by:
Cause: The part size is not within [p/m]10% of the values indicated by the Part data.
Remedy: Check the Part data. Also, check for soiling of the nozzle or the part. Make sure that the correct
part is being processed.
------------------------------
Code: 1D354045
Display: Same as code.
Used by:
Cause: The parts inclination is not within [p/m]15%, or the part is not rectangular.
Remedy: Check the Part data. Also, check for soiling of the nozzle or the part. Make sure that the correct
part is being processed.
------------------------------
Code: 1D354046
Display: Same as code.
Used by:
Cause: This error occurs when the image quality is unstable (due to soiling of the nozzle or the part),
when the part shape is inappropriate (e.g. when there are protrusions or concavities), or when there is a
large discrepancy between Part data values and the actual values for the part.
Remedy: Check for soiling of the nozzle or the part. Make sure that the correct part is being processed.
------------------------------
Code: 1D354047
Display: Same as code.
Used by:
Cause: This error occurs when the image quality is unstable (due to soiling of the nozzle or the part),
when the part shape is inappropriate (e.g. when there are protrusions or concavities), or when there is a
large discrepancy between Part data values and the actual values for the part.
Remedy: Check for soiling of the nozzle or the part. Make sure that the correct part is being processed.
------------------------------
Code: 1D354048
Display: Same as code.
Used by:
Cause: No leads could be found.
Remedy: Check the part's shape and the Part data.
------------------------------
Code: 1D354049
Display: Same as code.
Used by:
Cause: The lead pitch is not within the allowable range.
Remedy: Check the part's shape.
------------------------------
Code: 1D35404A
Display: Same as code.
Used by:
Cause: The part could not be found. The part's outline could not be identified.
Remedy: Check the Part data and the manner in which the part is picked up. Check the image
acquisition conditions.
------------------------------
Code: 1D35404B