Remedy: Replace the part that caused the error or increase the "copla_tolerance" item value in part data. ------------------------------ Code: 12070?6E Display: "ICM(PMC?,SCU?) Error Code:********" (Q…

100%1 / 5282
Placing pressure calculation could not be carried out because pressure offset of relevant nozzle was not
executed or Proper data was incorrect.(QP3)
Remedy: Perform placing pressure calibration for the nozzle to be used, and measure the necessary
Proper data values.(QP2)
Carry out regular placing pressure offset of relevant nozzle.(QP3)
------------------------------
Code: 12070?69
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No PPC calibration pos." (QP2)
Regular placing pressure control alarm (QP3)
Used by: QP242,QP3
Cause: A placing pressure control calibration position has not been set in the Proper data.(QP2)
(value replacing "?" is module number; error code appears in place of asterisks)
Regular placing pressure zero adjustment not carried out since placing pressure offset position
measurement has not been executed.(QP3)
Remedy: Use the [MEASURE PROPER] command to measure the placing pressure calibration
position.(QP2)
Carry out placing pressure offset position measurement.(QP3)
------------------------------
Code: 12070?6A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Remover up/down timeout" (QP2)
Used by: QP242
Cause: A timeout has occurred while raising or lowering the remover.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that nothing is interfering with the remover. Use I/O commands to make sure that
the remover moves smoothly, and that the upper limit and lower limit sensors are functioning normally.
------------------------------
Code: 12070?6B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Linearity Tolerance Error" (QP2)
Used by: QP242
Cause: A linearity tolerance error has occured.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Replace the part that caused the error or increase the "linear_tolerance" item value in part data.
------------------------------
Code: 12070?6C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Lead Quantity Error" (QP2)
Used by: QP242
Cause: A lead quantity error has occured.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Replace the part that caused the error or check that the number of leads on the part matches
with the number of leads recorded in part data.
------------------------------
Code: 12070?6D
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Coplanarity Tolerance Error" (QP2)
Used by: QP242
Cause: A coplanarity tolerance error has occured.
(value replacing "?" is module number; error code appears in place of asterisks)
第 733 页
Remedy: Replace the part that caused the error or increase the "copla_tolerance" item value in part data.
------------------------------
Code: 12070?6E
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Within LLL sensor range" (QP2)
Used by: QP242
Cause: Within LLL sensor range.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Increase the value of the part data item, "lead_offset" where the error occured. Alternatively,
change the currently used nozzle to one of smaller diameter.
------------------------------
Code: 12070?6F
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Scan_area too large" (QP2)
Used by: QP242,QP201,QP202
Cause: The scan area is too large.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Check that the part does not exceed the maximum size that can be handled by the vision
processing system. If the scan area is set in part data, check that value.
------------------------------
Code: 12070?70
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Scan area is not set" (QP2)
Used by: QP242,QP201,QP202
Cause: The scan area is not set.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error does not normally occur.
------------------------------
Code: 12070?71
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Orientation Check Error Check the orientation of the tray" (QP2)
Used by: QP201,QP202
Cause: This is an orientation error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Correct the orientation of the tray and rearrange the packages so that starting from the upper
left hand corner moving downward, the packages fill the tray leaving the bottom right hand corner empty.
------------------------------
Code: 12070?72
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Dummy Parts" (QP2)
Used by: QP201,QP202
Cause: These are dummy parts.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: No remedy is required.
------------------------------
Code: 12070?75
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"No Tray / Tray Unit Full" (QP2)
Used by: QP201
Cause: (APL) There are no supply trays or, the unloading elevator is full.
(value replacing "?" is module number; error code appears in place of asterisks)
第 734 页
(CTL) There are no storage trays or, the unloading elevator is full.
Remedy: (APL) Load supply trays or remove the empty trays.
(CTL) Load storage trays or remove the finished trays.
------------------------------
Code: 12070?76
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parts lost from nozzle" (QP2)
Used by: QP201,QP202
Cause: Parts lost from nozzle.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Place lost parts onto the tray.
------------------------------
Code: 12070?77
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parts pick-up error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Failed to pick-up the part.
Remedy: Check the parts supply.
------------------------------
Code: 12070?78
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Parts placement error" (QP2)
Used by: QP242, QP202,QP203
Cause: Failed to place part.
Remedy: Check to see if the head is holding a part.
------------------------------
Code: 12070?79
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Cannot move Z-axis, Q-axis outside its movement range." (QP2)
Used by: QP202,QP203
Cause: The Z-axis cannot be moved because the Q-axis is outside its acceptable movement range.
Remedy: Correct the angle of the Q-axis by up to +-15 deg..
------------------------------
Code: 12070?7A
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Cannot move Q-axis, Z-axis outside its movement range." (QP2)
Used by: QP202
Cause: The Q-axis cannot be rotated because the Z-axis is outside its acceptable movement range.
Remedy: Adjust the height of the Z-axis so that it is above the height of the arch motion limit.
------------------------------
Code: 12070?7B
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Cannot move Q-axis as it is outside its rotation range."
Used by: QP202,QP203
Cause: The Q-axis cannot be rotated because it is outside its rotation range.
Remedy: Correct the angle of the Q-axis by up to +-15 deg.
------------------------------
Code: 12070?7C
Display: "ICM(PMC?,SCU?) Error Code:********" (QP2)
"Specified angle is outside Q-axis rotation range." (QP2)
Used by: QP202,QP203
第 735 页