FUJI错误代码查询.pdf - 第1082页
excessive. There may be a foreign object on the nozzle. Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign objects from the nozzle. ------------------------------ Code: 14…
------------------------------
Code: 14040001
Display: 14040001
Used by:
Cause: The nozzle could not be found.
Remedy: Check the condition under which parts are being supplied.
------------------------------
Code: 14040002
Display: 14040002
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040003
Display: 14040003
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040004
Display: 14040004
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040005
Display: 14040005
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040006
Display: 14040006
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040007
Display: 14040007
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
第 1081 页
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040008
Display: 14040008
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040009
Display: 14040009
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 1404000A
Display: 1404000A
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 1404000B
Display: 1404000B
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 1404000C
Display: 1404000C
Used by:
Cause: The length in the y direction is too small.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 1404000D
Display: 1404000D
Used by:
Cause: The length in the y direction is too small.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 1404000F
第 1082 页
Display: 1404000F
Used by:
Cause: The image was not correctly acquired. The unevenness on the top or bottom of the part is
excessive. There may be a foreign object on the nozzle.
Remedy: Check the camera, the vision processing board, the cable, and the focus. Remove any foreign
objects from the nozzle.
------------------------------
Code: 14040010
Display: 14040010
Used by:
Cause: The length in the x direction is too small.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 14040011
Display: 14040011
Used by:
Cause: The length in the x direction is too big.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 14048002
Display: 14048002
Used by:
Cause: The nozzle cannot be found. There is nothing in the image.
Remedy: Check that the nozzle diameter specified in Proper data is correct and that the CCD level in the
acquired image is correct.
------------------------------
Code: 140482??
Display: 140482??
Used by:
Cause: The nozzle length is too long in the x direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 140483??
Display: 140483??
Used by:
Cause: The nozzle length is too short in the x direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 140484??
Display: 140484??
Used by:
Cause: The nozzle length is too long in the y direction.
Remedy: Check the nozzle. Check that the nozzle diameter specified in Proper data is correct and that
the CCD level in the acquired image is correct.
------------------------------
Code: 140485??
Display: 140485??
第 1083 页