Cause: Job的导出失败了。 Remedy: 请确认stream功能的Job参数 ------------------------------ Code: 18099001 Display: 没找到相应的Job名或者换线ID Used by: SECS/GEM Cause: 指定了不存在的Job名或者换线ID。 Remedy: 请设定正确的Job名或者换线ID。 ------------------------------ Cod…

100%1 / 5282
Used by: SECS/GEM
Cause: 远程指令的参数项目和值不正确。
Remedy: 请设定正确值。
------------------------------
Code: 18098011
Display: 未对应远程指令
Used by: SECS/GEM
Cause: 发行了不对应的远程指令。
Remedy: 请确认SECS/GEM使用手册。
------------------------------
Code: 18098012
Display: OnlineLocal模式异常
Used by: SECS/GEM
Cause: 发行了Online Local时不能实行的远程指令。
Remedy: 请从主机切换到Online Remote,或者等待机器切换到Online Remote后再实行。
------------------------------
Code: 18098013
Display: TransactionID错误
Used by: SECS/GEM
Cause: 远程指令RESPONSERESULT、RESPONSELOAD时,使用与报告时不同的TransactionID接受了来自主
机的判定通信。
Remedy: 请使用与报告时相同的TransactionID发行远程指令。
------------------------------
Code: 18098014
Display: RequestCEID错误
Used by: SECS/GEM
Cause: 对于远程指令RESPONSERESULT,使用与报告时不同的CEID进行了报告。
或者使用未对应的CEID进行了报告。
Remedy: 请将报告时的CEID安装到RequestCEID,并发行远程指令。
------------------------------
Code: 18098021
Display: Job转送错误
Used by: SECS/GEM
Cause: 从主机向Nexim生产程序转送失败了。
Remedy: 请确认stream功能的参数。S7F3/S7F4握手(Hand Shake)不能转送16MB以上的文件。
------------------------------
Code: 18098022
Display: Job转送错误
Used by: SECS/GEM
Cause: 从Nexim向主机生产程序转送失败了。
Remedy: 请确认stream功能的参数。S7F5/S7F6握手(Hand Shake) 能转送16MB以上的文件。
------------------------------
Code: 18098023
Display: Job导入错误
Used by: SECS/GEM
Cause: Job的导入失败了。
Remedy: 请确认stream功能的Job参数请确认用手操作能否在Nexim导入目的文件。
------------------------------
Code: 18098024
Display: Job导出错误
Used by: SECS/GEM
第 1173 页
Cause: Job的导出失败了。
Remedy: 请确认stream功能的Job参数
------------------------------
Code: 18099001
Display: 没找到相应的Job名或者换线ID
Used by: SECS/GEM
Cause: 指定了不存在的Job名或者换线ID。
Remedy: 请设定正确的Job名或者换线ID。
------------------------------
Code: 18610025
Display:
Used by:
Cause:
Remedy:
------------------------------
Code: 1C010001
Display: 1C010001
Used by:
Cause: The memory capacity was insufficient (SMD2). The memory was insufficient (SMD3) (memory
allocation error).
Remedy: Delete all of the GD on the machine and then retransmit (SMD2). Expand the vision processing
board memory (SMD3). Replace the vision processing board. There is too much part data. Reduce the
number of parts.
------------------------------
Code: 1C010002
Display:
Used by:
Cause: The same ID number is used on 2 or more types of Part data.
Remedy: Clear all the GD from the machine, input ":idg -a" (ID number distribution) at the UCI menu,
and retransmit.
------------------------------
Code: 1C090001
Display:
Used by:
Cause: This error occurred during vision processing. The part cannot be placed.
Remedy: The GD coarse edge data (Polarity) is incorrect. Check e1_polarity and e3_polarity at the GD
editor.
------------------------------
Code: 1C120002
Display:
Used by:
Cause: The model is larger than the image.
Remedy: Check that the program model size matches the image size.
------------------------------
Code: 1C140001
Display: 1C140001
Used by:
Cause: Access was outside of the memory range (path error).
Remedy: The part data dimensions were outside of the image display range. Check the dimensions of the
part in part data. The boundaries could not be found. Check the nozzle center.
------------------------------
第 1174 页
Code: 1C190000
Display: 1C190000
Used by:
Cause: There was an image acquisition failure using the line scan camera.
(Direction change was too fast.)
Remedy: Check the wiring and the scanning speed.
------------------------------
Code: 1C190001
Display: 1C190001
Used by:
Cause: The specified data is out of range. (Bad argument)
Remedy: Make sure that portions of the part image do not extend off the screen. Check the dimensions of
the part in part data.
------------------------------
Code: 1C200001
Display:
Used by:
Cause: The model window is too close to edge of the field.
Remedy: Change the program so that the model is seen in the center of the field.
------------------------------
Code: 1C200002
Display:
Used by:
Cause: The image has insufficient intensity variations (i.e. zero) within the model window. There must be
some contrast between the foreground and background.
Remedy: Select another area or image from which to make the model.
------------------------------
Code: 1C230007
Display: 1C230007
Used by:
Cause: The image was not acquired by the line scan camera. The movement speed of the part being
vision processed was too fast.
Remedy: Reduce the movement speed of the part in question when the image is being acquired.
------------------------------
Code: 1C230008
Display: 1C230008
Used by:
Cause: The image was not acquired by the line scan camera. The movement of the part being vision
processed stopped during image acquisition.
Remedy: Machine operation halted while the image was being acquired. Rectify the cause of this
stoppage and then carry out vision processing again.
------------------------------
Code: 1C310005
Display:
Used by:
Cause: This code occurs during camera Proper data measurements. The image is too dark.
Remedy: Slightly increase the camera gain and re-measure the Proper data.
------------------------------