------------------------------ Code: 2100774B Display: Illegal format at Cam_table Used by: Cause: The cam table is not formatted correctly. Remedy: Re-install the Automatic Programming software. ------------------------…
Cause: The base program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007743
Display: Illegal format at Machine type table
Used by:
Cause: The machine type table format is illegal.
Remedy: Re-install the software.
------------------------------
Code: 21007744
Display: Make not mount sequence
Used by:
Cause: The queue data used in the strategy section of the system file could not be created.
Remedy: Re-boot MCS. If the error recurs, replace the MPU (memory) board.
------------------------------
Code: 21007745
Display: No entry Machine name
Used by:
Cause: The machine entered in the "Type" heading in "Sep_data" could not be found.
Remedy: Input the correct machine name under the "Type" (do not forget to also input "Time" and
"Device_Name") heading.
------------------------------
Code: 21007746
Display: Cam_table file open error
Used by:
Cause: The system file could not be opened.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 21007747
Display: Cam_table file read error
Used by:
Cause: The system file could not be read.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 21007748
Display: Cam_table file seek error
Used by:
Cause: The seek function did not work on the system file.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 21007749
Display: Cam_table file path read error
Used by:
Cause: The input path could not be specified.
Remedy: Re-boot MCS. If the error recurs, re-install the software.
------------------------------
Code: 2100774A
Display: Not get cycle time
Used by:
Cause: Management time could not be calculated.
Remedy: Re-install the Automatic Programming software.
第 1964 页
------------------------------
Code: 2100774B
Display: Illegal format at Cam_table
Used by:
Cause: The cam table is not formatted correctly.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100774C
Display: Pairing pattern file open error
Used by:
Cause: The system file could not be opened.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100774D
Display: Pairing pattern file read error
Used by:
Cause: The system file could not be read.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100774E
Display: Pairing pattern file file value different
Used by:
Cause: The contents of the system file are not normal.
Remedy: Re-install the Automatic Programming software.
------------------------------
Code: 2100774F
Display: Not get queue position
Used by:
Cause: Memory could not be processed.
Remedy: Re-boot MCS.
------------------------------
Code: 21007750
Display: Sequence data co-ordinates over range
Used by:
Cause: There was a memory management error.
Remedy: Re-boot MCS. If the problem recurs, re-install the software.
------------------------------
Code: 21007751
Display: Sequence data co-ordinates over range
Used by:
Cause: The coordinates in the sequence data are outside the board range.
Remedy: Check that the correct values are input in XA, YA, Pcb_x and Pcb_y in the production program.
Check that the correct values are input in Pcb_org in the environment file. Pcb_org=x,y, board orientation
and change flag should be checked. The check flag could be either 0 or 1.
------------------------------
Code: 21007752
Display:
Used by:
Cause: The environment file could not be opened.
Remedy: Re-install the software.
------------------------------
第 1965 页
Code: 21007753
Display:
Used by:
Cause: The environment file could not be read.
Remedy: Re-install the software.
------------------------------
Code: 21007754
Display: different device type arranged at same stn.
Used by:
Cause: When device data was rearranged, the largest station returned to station 1.
Remedy: Reduce the number of next devices in the input program and reexecute the function.
------------------------------
Code: 21007755
Display: "Not PST file"
Used by:
Cause: A file that has been specified as a PST file does not have the ".pst" extension.
Remedy: Specify a PST file as the permanent set table.
------------------------------
Code: 21007756
Display: "Feeder position in PT file is out of range"
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 21007757
Display: "There is insufficient space for a feeder in PT file"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007758
Display: "Space between feeders in PT file is insufficient"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007800
Display:
Used by:
Cause: There was an illegal parameter in the startup option (+wtlb).
Remedy: Check the startup option and restart.
------------------------------
Code: 21007801
Display: Message file read error
Used by:
Cause: The message file could not be read.
Remedy: Re-install MCS.
------------------------------
Code: 21007802