FUJI错误代码查询.pdf - 第177页

Cause: The ICM panel confirmation time setting is incorrect. Remedy: Ensure that the "ICM Board Check Timer" item in Proper data is set to the default (0), or to a value of 10 or more. -------------------------…

100%1 / 5282
145: PCB Pickup position MX
146: PCB Landing position MX
147: PCB Landing position MX_FWD
162: Max_Limit_Position_MX
163: Max_Limit_Position_MY
166: Min_Limit_Position_MX
162: Min_Limit_Position_MY
For example, if the item "141: Mark Read Position MXC" is set to "140000", this should be changed
to "280000", and retransmission then performed.
------------------------------
Code: 11022A35
Display: Same as the code
Used by: QP201 (APL)
Cause: Use of the raised part detection sensor has been enabled in Proper data, but the appropriate
setting has not been made for carrier unclamping.
Remedy: Check the settings at the Proper data item, "PLM? Machine Status" (? represents the module
number).
Raised part detection sensor attached: 0000 1000 0000 0000
Independent carrier unclamping: 0000 0100 0000 0000
------------------------------
Code: 11022A36
Display: Same as the code
Used by: QP201 (APL)
Cause: The raised part recovery setting has been made more than once.
Remedy: Specify just one of the following settings at the Proper data item, "Machine Status B".
Reinspect: 0001 0000 0000 0000
Reselect: 0010 0000 0000 0000
Push part: 0100 0000 0000 0000
Error: 1000 0000 0000 0000
------------------------------
Code: 11022A37
Display: Same as the code
Used by: QP201 (APL)
Cause: Data necessary to perform a raised part check has not been specified.
Remedy: Make settings at the following Proper data items
Laser Check Speed
Laser Zero Point 1
Laser Check Point 1
------------------------------
Code: 11022A38
Display: "PM?? @ ERROR Code:********"
PMC SERVO PARAMETER ERROR
Used by: QP132
Cause: PMC servo parameter is not correctly set in Proper data.
The Moule number is reqresented by ??, and the axis is reqresented by @.
Remedy: Check the PMC servo parameter for the displayed Module number and axis, and make
adjustments as required.
------------------------------
Code: 11022A39
Display: Same as the code
Used by: QP242
第 176 页
Cause: The ICM panel confirmation time setting is incorrect.
Remedy: Ensure that the "ICM Board Check Timer" item in Proper data is set to the default (0), or to a
value of 10 or more.
------------------------------
Code: 11022A40
Display: Same as the code
Used by: QP242
Cause: The ICM loader time-out setting is incorrect.
Remedy: Ensure that the "ICM Loader Wait Timer" item in Proper data is set to the default (0), or to a
value of 15 or more.
------------------------------
Code: 11022A41
Display: Same as the code
Used by: QP132
Cause: A setup of Proper data(2408:Camera2 Vacuum On Timing [msec]) is not right.
Remedy: Please check a setup of Proper data(2408:Camera2 Vacuum On Timing [msec]).
------------------------------
Code: 11022B00
Display: 因为不能读取上一次关机时所保存的固有值,读取了再上一次关机时所保存的固有值。
进行固有值的确认,必要时请进行再测定和再设定。
Used by: XP141,XP241,XP341,XP142,XP242
Cause: 因为不能读取上一次关机时所保存的固有值,读取了再上一次关机时所保存的固有值。
Remedy: 进行固有值的确认,必要时请重新进行测定和设定。
------------------------------
Code: 11025?02
Display: Same as Code.
Used by: QP132
Cause: The PMC's program placement origin X coordinate is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Program Origin X0" to the correct value. This Proper data item exists
for each module. Module one is number 697 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?03
Display: Same as Code.
Used by: QP132
Cause: The PMC's program placement origin Y coordinate is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Program Origin Y0" to the correct value. This Proper data item exists
for each module. Module one is number 698 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?04
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?05
Display: abolished
Used by: QP132
第 177 页
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?06
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?07
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?08
Display: abolished
Used by: QP132
Cause: abolished
Remedy: abolished
------------------------------
Code: 11025?09
Display: Same as Code.
Used by: QP132
Cause: The PMC's reference pick-up position X is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Device Origin D0_X" to the correct value. This Proper data item exists
for each module. Module one is number 719 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0A
Display: Same as Code.
Used by: QP132
Cause: The PMC's reference pick-up position Y is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Device Origin D0_Y" to the correct value. This Proper data item exists
for each module. Module one is number 720 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0B
Display: Same as Code.
Used by: QP132
Cause: The PMC's reference parts eject position X is not set.
The "?" represents the module number in hexadecimal format. ("0" is PMC 16)
Remedy: Set the Proper data item "Parts Eject Pos_X" to the correct value. This Proper data item exists
for each module. Module one is number 721 in Proper data. Thereafter, add (PMC No. -1) times 82 to
locate this item for each module.
------------------------------
Code: 11025?0C
Display: Same as Code.
Used by: QP132
第 178 页