FUJI错误代码查询.pdf - 第2173页

Remedy: <XP142>Set Packaging to 1:Bulk,2:32mm Adhesive,3:12mm (no U-groove)Embossed,16or24mm Embossed,5:8mm Paper or Embossed,12mm (U-groove)Embossed,or 7:32mm Embossed. <XP242>Set Packaging to 0:Tray,2:32mm …

100%1 / 5282
"Nozzle configuration"on the "Nozzle optimization screen",check the arrangement of the nozzles on the
machine.
If "Use program nozzle configuration"was selected,check the nozzle arrangement in the program.
If this does not resolve the problem,optimize using the "Configure nozzles automatically"setting.
------------------------------
Code: 23078824
Display: A required nozzle does not exist in the nozzle list on the machine.
Used by:
Cause: <XP*42>The nozzle selected under Nozzle Name in the Part Type data is not listed on the
machine.If a Nozzle Name has not been set,no listed nozzle can handle the range between the Minimum
and Maximum Nozzle Diameter values set.
Remedy: <XP*42>Check the Nozzle Name,Minimum Nozzle Diameter and Maximum Nozzle Diameter in
the Part Type data.
------------------------------
Code: 23078827
Display: A slot that has not been allocated a part number is set as an Alt.Feeder.
Used by:
Cause: <XP*42>A vacant slot number (no setting data)is set as the Alt.Feeder.
Remedy: <XP*42>Specify a slot number with a same part number.
------------------------------
Code: 2307903C
Display: Slot number is not defined.
Used by:
Cause: <XP*42>Slot number is not defined.
Remedy: <XP*42>Input the Slot number.
------------------------------
Code: 2307904A
Display: The Alt.Feeder function is not looping.
Used by:
Cause: <XP*42>An Alt.Feeder setting which includes two different stages is not suitable for the loop type
setting.
Remedy: <XP*42>Change the setting so that the Alt.Feeder setting has the same stage-slot number.
------------------------------
Code: 2307904B
Display: The Alt.Feeder is outside the permitted range.
Used by:
Cause: <XP*42>The Alt.Feeder input is outside the permitted range.The designated slot number does not
exist.
Remedy: <XP*42>Enter an Alt.Feeder within the permitted range.
------------------------------
Code: 23079828
Display: The Alt丏Feeder must be set to a separate feeder.
Used by:
Cause: <XP*42>The Slot Number and Alt丏Feeder are identical.
Remedy: <XP*42>Specify a Alt丏Feeder which is different from the slot number.
------------------------------
Code: 2307A10C
Display: Unregistered Packaging Type.A feeder cannot be selected.
Used by:
Cause: <XP*42>Cannot optimize because feeder width is unknown.A registered Packaging Type must be
used so that a feeder can be selected.
第 2172 页
Remedy: <XP142>Set Packaging to 1:Bulk,2:32mm Adhesive,3:12mm (no U-groove)Embossed,16or24mm
Embossed,5:8mm Paper or Embossed,12mm (U-groove)Embossed,or 7:32mm Embossed.
<XP242>Set Packaging to 0:Tray,2:32mm Adhesive,3:12mm (no U-groove)Embossed,16or24mm
Embossed,4:Stick Feeder,5:8mm Paper or Embossed,12mm (U-groove)Embossed,7:32mm and Over
Embossed or 9:Stick (U-groove)Feeder.
------------------------------
Code: 2307E000
Display: PlaceBefore is set to loop.
Used by:
Cause: Cannot optimize because PlaceBefore is set to loop.
Remedy: Do not set PlaceBefore to loop in the sequence data.
------------------------------
Code: 2307E001
Display: The stage-slot number does not match the packaging type in part data.
Used by:
Cause: A part number with a Packaging Type of "Tray"is set for a Feeder stage-slot number or a part
number with a Packaging Type other than "Tray"is set for a Tray stage-slot number.
Remedy: For Feeder stage-slot numbers,specify a part number with a Packaging Type other than
"Tray".For Tray stage-slot numbers,specify a part number with Packaging Type of "Tray".Another option is
to optimize selecting "Configure feeders automatically"under "Feeder configuration"in the "Feeder
optimization"screen.
------------------------------
Code: 2307E002
Display: The part number does not match that of the Alt丏Feeder.
Used by:
Cause: The slot designated as Alt丏Feeder has a part number different from the one currently being
used.
Remedy: Select an Alt丏Feeder that has a part number that is the same as the one currently being used.
------------------------------
Code: 2307E003
Display: An unavailable stage is set in the feeder setup data.
Used by:
Cause: Stage 2 is set in the feeder setup data for the single side parts supplying machine.
Remedy: Either delete the stage 2 feeder data,or move them to stage 1.
------------------------------
Code: 2307E004
Display: The part size or Scan Area X,Scan Area Y setting exceeds the scanning range that can be handled
by the camera.
Used by:
Cause: The part size or Scan Area X,Scan Area Y setting exceeds the scanning range that can be handled
by the camera.
Remedy: Specify a part size or Scan Area X,Scan Area Y setting value that is within the scanning range
that can be handled by the camera.
With the Pick-up Point Offset X and Pick-up Point Offset Y settings taken into account,the maximum
part size that may be specified is 20 mm 事20 mm,and the maximum scan area is 25 mm 事24 mm,
------------------------------
Code: 2307E005
Display: A nozzle that matches nozzle number **cannot be found.
Used by:
Cause: A nozzle that matches nozzle number **cannot be found.
Remedy: If optimization was performed using the "Use machine nozzle configuration"setting under "Nozzle
第 2173 页
configuration"in the "Nozzle optimization"screen,check the nozzle set up on the machine.
If optimization was performed using the "Use program nozzle configuration"setting,check the nozzle
set up in the program.
Otherwise,perform optimization using the "Configure nozzles automatically"setting.
------------------------------
Code: 2307E006
Display: The part cannot be picked up because it interferes with an adjacent nozzle.
Used by:
Cause: The part cannot be picked up because it interferes with an adjacent nozzle.
Remedy: If optimization was performed using the "Use machine nozzle configuration"setting under "Nozzle
configuration"in the "Nozzle optimization"screen,check the nozzle configuration on the machine.
If optimization was performed using the "Use program nozzle configuration"setting,check the nozzle
configuration in the program.
Otherwise,perform optimization using the "Configure nozzles automatically"setting.
------------------------------
Code: 2307E007
Display: The same name has been allocated to [Place Before]and [Reference]([Sequence Comment]).
Used by:
Cause: The same name has been allocated to the [Place Before]and [Reference]([Sequence
Comment])sequences.
Remedy: Specify different names for the [Place Before]and [Reference]([Sequence Comment])sequences.
------------------------------
Code: 2307E008
Display: Duplicate [Reference]([Sequence Comment])sequences exist for the same board.
Used by:
Cause: Duplicate [Reference]([Sequence Comment])sequences exist for the same board.
Remedy: Create sequences so that [Reference]([Sequence Comment])sequences are not duplicated for the
same board.
------------------------------
Code: 2307E009
Display: Optimization was performed using the [Fix feeder configuration]setting,but it is possible that
trays cannot be arranged.
Used by:
Cause: Feeder optimization/Feeder configuration was performed using the [Fix feeder configuration (Do
not change feeder positions)]setting,but it is possible that trays cannot be arranged.
Remedy: Check that trays can be arranged.
------------------------------
Code: 2307F000
Display: Optimizer system error.
Used by:
Cause: Optimizer system error.
Remedy: This is an internal error.This error should not occur under normal circumstances.Acquire trace
data and contact your Fuji representative.
------------------------------
Code: 2307F001
Display: Optimizer system error.
Used by:
Cause: Optimizer system error.
Remedy: This is an internal error.This error should not occur under normal circumstances.Acquire trace
data and contact your Fuji representative.
------------------------------