Used by: Cause: The Part data, referred to by a sequence slot that contains no skipped board/feeder/sequence setting, does not exist. Remedy: The program file is incorrect. Check and correct the file contents. ----------…

100%1 / 5282
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2305004A
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a loop did not exist. The Alt. Feeder setting is zero.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2305004B
Display: The Alt. Feeder is not in a loop. Set the final slot in the loop to point back to the first slot in the
loop?
Used by:
Cause: When arriving at a alternate feeder, a non-existent Alt. Feeder setting was found.
Remedy: In the program file's Feeder Setup settings, check that the Alt. Feeder value
(PROGRAM/DEVICE+/GUTNSLTN) is correct.
------------------------------
Code: 2305004C
Display: Nozzle name is not specified. Assume as a standard nozzle?
Used by:
Cause: In the Nozzle folder information file, the Nozzle name is not specified for "GNANAM".
Remedy: When [Yes] is selected, standard Nozzle name is specified according to the diameter. When [No]
is selected, no Nozzle is specified to the Nozzle folder.
------------------------------
Code: 230500A1
Display: The source program is already in an optimized condition. It is not possible to further optimize the
source program.
Used by:
Cause: The post-optimized theoretical cycle time is slower than the pre-optimized time, however, source
program sequence or feeder setup problems have been fixed.
Remedy: It may be possible to achieve a better cycle time result by changing the optimization conditions,
if production constraints allow.
------------------------------
Code: 23060003
Display: The tape width is outside the specifications or is zero.
Used by:
Cause: The packaging name (PARTS/HEADER/CMPNAME) or the tape width (PARTS/PACKLS-
/TAPEWIDTH) is outside the specifications or is zero. For packaging name, one of the following types must
be specified: E08xx, E12xx, E16xx, E24xx, E32xx, J32xx, E44xx, E56xx, E72xx, E88xx. For tape width,
one of the following must be specified: 8, 12, 16, 24, 32, 44, 56, 72, 88.
Remedy: The tape width setting in the part data is incorrect. Check the file contents.
------------------------------
Code: 23060005
Display: A feeder does not exist in the slot referred to in the sequence.
Used by:
Cause: A feeder does not exist in the slot referred to in the sequence.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23060006
Display: Part data referred to by the sequence slot does not exist.
第 2161 页
Used by:
Cause: The Part data, referred to by a sequence slot that contains no skipped board/feeder/sequence
setting, does not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 23060008
Display: No feeder exists in the slot referenced by this skipped sequence (for skipped sequences included
in optimization).
Used by:
Cause: A feeder does not exist in a sequence slot that contains board/feeder/sequence skip settings.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 2306000A
Display: No part data exists for the slot referenced by this skipped sequence (for skipped sequences
included in optimization).
Used by:
Cause: The part data referred to by a sequence slot containing board/feeder/sequence skip settings does
not exist.
Remedy: The program file is incorrect. Check and correct the file contents.
------------------------------
Code: 2306000D
Display: The Alt. Feeder does not exist. Do you want to set 0 for alternate feeder?
Used by:
Cause: A feeder is not set in the Alt. Feeder specified for the displayed stage-slot.
Remedy: The Feeder Setup information in the program file is incorrect. Check the settings.
------------------------------
Code: 2306000E
Display: There are too many feeders allocated to one stage.
Used by:
Cause: When automatic feeder arrangement was selected at the Optimize Condition settings screen, the
number of feeders allocated to the stage exceeded the maximum feeder slots.
Remedy: Firstly, try changing the [Use Feeder Type] settings. If unsuccessful, perform optimization using
the [Alt. Feeders Are Removed] setting. If still unsuccessful, reduce the part varieties used in the program.
------------------------------
Code: 23060010
Display: A currently unused feeder has been fixed, however, no part data exists for that slot.
Used by:
Cause: There is no part data displayed in the Feeder Setup.
Remedy: The program file data is incorrect. Check the contents.
------------------------------
Code: 23060012
Display: When using [Fix Feeders], there is no such slot available for the feeder.
Used by:
Cause: The specified stage - slot number does not exist.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23060013
Display: When using [Fix Feeders], a feeder is too wide to place at an end slot was specified.
Used by:
第 2162 页
Cause: In the program's feeder setup, a feeder too wide to place at an end slot was specified.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 23060015
Display: A feeder included in fixed feeder processing cannot be loaded on the stage because it is too close
to the feeder to the left.
Used by:
Cause: In the program's feeder setup, a feeder wide enough to interfere with the adjacent feeder on the
left side.
Remedy: Check the program file's stage number (PROGRAM/DEVICE+/GUTSTN) and slot number
(PROGRAM/DEVICE+/GUTSLTN), or alternatively, use the [Automatic Most Suitable Feeder Arrangement]
setting for optimization.
------------------------------
Code: 2306001A
Display: Are you finished?
Used by:
Cause: The confirmation dialog displays at each time of completion.
Remedy: Select [Yes] to finish. Select [No] to continue.
------------------------------
Code: 2306001B
Display: The optimized program has not been saved yet. Will you save it?
Used by:
Cause: Attempting to open the program file, or optimization process has completed, but the optimized
program has not been saved to the file.
Remedy: Select [Yes] to display the dialog for saving the file with a new name.
When attempting to open the program file, select [No] to abandon the optimized program, and display the
dialog for selecting a new program file to be optimized.
When optimization process has completed, select [No] to exit without saving the optimized program.
------------------------------
Code: 2306001C
Display: No nozzle is registered.
Used by:
Cause: No valid nozzle match could be made between the Nozzle Config. file's NCFTYPE and the Nozzle
Spec. file's NSPNAME.
Remedy: There is a problem with either or both files. Normally, the Nozzle Config. and Nozzle Spec. files
in the MCS-X default directory are read automatically. Check that both files contain correct data. When
starting up the optimizer, in cases where prompted to specify a file because the default file cannot be
found, check the file contents and correct if necessary.
------------------------------
Code: 2306001D
Display: Nozzle Configuration File "Fujinzl.cfg" cannot be found. Specify a file?
Used by:
Cause: An attempt was made to read the Nozzle Config. File in the MCS-X default directory, but the file
could not be found. A file needs to be specified to continue.
Remedy: Select [Yes] to display the dialog for specifying a file. Select [Abort] to quit the optimizer.
------------------------------
Code: 2306001E
Display: The contents of Nozzle Configuration File are empty.
Used by: