ˇ The nozzle is of the index type. ˇ An STU is attached. In the above situation, parts being held by the nozzle may contact with parts in the tray. Remedy: Check that the setting at the "Tray Pickup Offset Z" i…

100%1 / 5282
Remedy: Set the correct value for the "Package Data Dimension_x (F4G)" parameter in the Part data.
------------------------------
Code: 11D48???
Display: Same as code The value replacing the first "?" is the station number; the values for the remaining
"??" indicate a device number within that station. These numbers appear as hexadecimal values. When a
device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242,QP201,QP202,QP203
Cause: No value has been set for the tray size Y dimension.
Remedy: Set the correct value for the "Package Data Dimension_y (F4G)" parameter in the Part data.
------------------------------
Code: 11D49???
Display: Same as code The first digit of the value replacing the "???" is the station number; the remaining
two digits indicate a device number within that station. These numbers appear as hexadecimal values.
When a device number greater than 256 is indicated, subtract 256 to find the device number.
Used by:
Cause: No "Tray_infomation" data has been transmitted in the Part data (for the FIP3).
Remedy: "Tray_infomation" data is necessary because a value of 6 or 7 has been set for the
"11.(Tray:)Tray_type (MCS/2)" parameter under "Package_and_appearance_data" in the Part data. Use a
host computer corresponding to Tray_type 6 or 7.
------------------------------
Code: 11D4A???
Display: Same as code The first digit of the value replacing the "???" is the station number; the remaining
two digits indicate a device number within that station. These numbers appear as hexadecimal values.
When a device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242
Cause: The tray part's specified pick-up position falls outside the tray dimensions.
Remedy: Retransmit the production program to the machine after correcting the following part data items:
"Tray First Pickup Point X,Y"
"Tray Cavity Pitch X,Y"
"Tray Cavity Quantity Side X,Y"
"Tray Dimension Size X,Y"
------------------------------
Code: 11D4B???
Display: Same as code The first digit of the value replacing the "???" is the station number; the remaining
two digits indicate a device number within that station. These numbers appear as hexadecimal values.
When a device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242
Cause: The empty tray's specified pick-up position falls outside the tray dimensions.
Remedy: Retransmit the production program to the machine after correcting the following part data items:
"Tray Eject Pickup Point X,Y"
"Tray Dimension Size X,Y"
------------------------------
Code: 11D4C???
Display: Same as code The first digit of the value replacing the "???" is the station number; the remaining
two digits indicate a device number within that station. These numbers appear as hexadecimal values.
When a device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242
Cause: Parts with an upper surface of more than 7 mm above the tray surface cannot be handled at
modules where all four of the following conditions apply.
ˇ Parts are being supplied from the front of the machine.
ˇ Camera type 7 is used.
第 282 页
ˇ The nozzle is of the index type.
ˇ An STU is attached.
In the above situation, parts being held by the nozzle may contact with parts in the tray.
Remedy: Check that the setting at the "Tray Pickup Offset Z" item in part data is set to +7.0 mm or less.
If this value is greater than 7.0 mm, production will not be possible at modules where the above
conditions are met, and the production program should be changed so that a different module is used.
------------------------------
Code: 11D50???
Display: 11D50???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by:
Cause: One of the following is the source of the error:
Pickup Offset X in part data for device number 1 is under -1 mm.
Pickup Offset X in part data for device number 23 is over + 1 mm.
Remedy: Because there is a limit on the X-axis stroke, set the offset to within this limit or for parts which
require a device offset, use device positions 2 to 22.
------------------------------
Code: 11D51???
Display: 11D51???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by:
Cause: if the sixth bit of "Machine_Status B" is set to "0",the part data item
"D_ofst_x" value range is +-2.8mm. if the sixth bit is set to "1",the value is +
-5.0mm. For the CP652C,device 1 or 30 in a pallet in the transmitted program exceeds this range.
Remedy: Check the value for the sixth bit in the Proper data item "Machine_Stat
------------------------------
Code: 11D60???
Display: 11D60???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203
Cause: The vision type required for vision processing is not specified.
Remedy: Specify correct data for 14. Vision_type in Part data's Vision_data.
------------------------------
Code: 11D61???
Display: 11D61???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: CP652C
Cause: A nozzle specified in part data in the production program is not in the nozzle assignment table
(NAT).
Remedy: Edit the part data and NAT to ensure that the nozzle size is correct and then re-transmit the
program.
------------------------------
Code: 11D62???
第 283 页
Display: 11D62???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: QP242,QP201,QP202,QP203,CP652C
Cause: (FLT, FIP3) During the device data check it was discovered that the machine does not have the
correct nozzle size to place one of the parts.
Remedy: (FLT, FIP3) Either install the required nozzle in the machine in order to place the part or change
17. Nozzle_size_max, 18. Nozzle_size_min, and 24. Nozzle name in part data's Carrying_data.
------------------------------
Code: 11D63???
Display: 11D63???
The first number in ??? indicates the station number (in hexadecimal).
The following two numbers indicate the device number in that station.
For device numbers above 256, 256 is displayed.
Used by: CP652C,QP132
Cause: The backlight diameter which is specified in header data is smaller than PD's smallest backlight
diameter.
Remedy: Input the correct backlight diameter and re-transmit the program.
------------------------------
Code: 11D64???
Display: Same as code The value replacing the first "?" is the station number; the values for the remaining
"??" indicate a device number within that station. These numbers appear as hexadecimal values. When a
device number greater than 256 is indicated, subtract 256 to find the device number.
Used by: QP242,QP201,QP202,QP203
Cause: The vision processing camera on the indicated QP242,QP201,QP202,QP203 station cannot
execute vision processing for the indicated device.
Remedy: Mount a camera capable of performing the necessary vision processing on the indicated
QP242,QP201,QP202,QP203 station. Also, set the appropriate data for this camera in the Camera Table
of the Part data.
------------------------------
Code: 11D65???
Display: Same as Code.
Used by: QP132
Cause: A nozzle related item in part data has not been set or the value that is set is not suitable.
The first "?" of the "???" represents the module number and the following "??" represent the device within
the module. The numbers are in hexadecimal format. If the device number is greater than 256, subtract
256.
Remedy: Set the following items:Nozzle_size_max, Nozzle_size_min, Nozzle_name.
------------------------------
Code: 11D66???
Display: Same as Code.
The first "?" represents the station number and the following "??" represent the device slot within the
station. Since the device slot number is represented in hexadecimal form, subtract 256 from any number
greater than 256.
Used by: QP242,QP201,QP202,QP203
Cause: Automatic selection of the BGA parts type camera cannot be made.
Remedy: Enter the camera selection manually.
------------------------------
Code: 11D67???
Display: Same as Code.