FUJI错误代码查询.pdf - 第208页

Code: 1107C004 Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C004 ID:* Used by: QP132 Cause: Receiving transmission time out error has occurred. *: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loa…

100%1 / 5282
Remedy: Check that the machine has finished changing programs and then input the command.
------------------------------
Code: 1107BF43
Display:
Used by:
Cause: Program is ineffective.
Remedy: None.
------------------------------
Code: 1107BF50
Display:
Used by:
Cause: The command was rejected because the machine was in device check.
Remedy: After device check is finished, re-enter the command.
------------------------------
Code: 1107BF60
Display:
Used by:
Cause: Processing was interrupted because the pallet number is ineffective.
Remedy: Check the pallet numbers in the production program.
------------------------------
Code: 1107BF61
Display:
Used by:
Cause: Processing was interrupted because the pallet number was not specified.
Remedy: Set the pallet number in the production program.
------------------------------
Code: 1107C001
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C001 ID:* E:??
Used by: QP132
Cause: The completion code for the response from the ID reader is not normal.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
??: Finishing code.
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
Code: 1107C002
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C002 ID:*
Used by: QP132
Cause: The text that has been received cannot be analyzed.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
Code: 1107C003
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C003 ID:*
Used by: QP132
Cause: Transmission time out error has occurred.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
第 207 页
Code: 1107C004
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C004 ID:*
Used by: QP132
Cause: Receiving transmission time out error has occurred.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected.
------------------------------
Code: 1107C005
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C005 ID:*
Used by: QP132
Cause: The allowable number of overwrites for this data carrier has been exceeded.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Change the relevant pallet's data carrier.
------------------------------
Code: 1107C006
Display: PIDRESPONSEEnd-CodeERRPID_ERR: 1107C005 ID:*
Used by: QP132
Cause: The data carrier is not operation correctly.
*: Approach station: 1-5, Mark lead module: 6, Landing station: 7, Pallet loader: 8
Remedy: Check that the index motion is being performed normally. Also check that the data carrier and
the controller, as well as the controller and machine's communication connecter, are connected. If this
occurs frequently, change the relevant pallet's data carrier.
------------------------------
Code: 1107D001
Display: Association error!
Used by: NP2,QP3
Cause: Failed to start up the association process.
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 1107D002
Display: Association error!
Used by: NP2,QP3
Cause: Failed to acquire association data.
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 1107D003
Display: DxShell call error!
Used by: NP2,QP3
Cause: An error occurred in the communication between the machine and the parts supply unit.
Remedy: Check if the parts supply unit and the feeders are correctly attached to the machine and restart
the machine.
------------------------------
Code: 1107D004
Display: Parts supply unit error!
Used by: NP2,QP3
Cause: Auto-start instruction error!
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
第 208 页
------------------------------
Code: 1107D005
Display: Parts supply unit error!
Used by: NP2,QP3
Cause: Auto-clear instruction error!
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 1107D006
Display: PFU calibration data error!
Used by: NP2,QP3
Cause: Failed to acquire PFU calibration data.
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 1107D007
Display: MTU calibration data error!
Used by: NP2,QP3
Cause: Failed to acquire MTU calibration data.
Remedy: Use the [Power On] command at the [Unit] command screen to turn the power to the parts
supply unit on.
------------------------------
Code: 1107D008
Display: Association error!
Used by: NP2,QP3
Cause: An association error occurred during LON communications.
Remedy: For removable stages: Use the [Power On] and [Power Off] commands at the [Unit] command
screen to turn the power to the parts supply unit on and off
------------------------------
Code: 1107D009
Display: Association error.
Used by: NP2,QP3
Cause: Failed to acquire association data.
Remedy: For removable stages: Use the [Power On] and [Power Off] commands at the [Unit] command
screen to turn the power to the parts supply unit on and off
------------------------------
Code: 1107D00A
Display: Parts supply unit error!
Used by: NP2,QP3
Cause: Parts supply unit error!
Remedy: For removable stages: Use the [Power On] and [Power Off] commands at the [Unit] command
screen to turn the power to the parts supply unit on and off
------------------------------
Code: 1107D00B
Display: Parts supply unit error!
Used by: NP2,QP3
Cause: Failed to normally complete the automatic operation start-up instruction.
Remedy: For removable stages: Use the [Power On] and [Power Off] commands at the [Unit] command
screen to turn the power to the parts supply unit on and off
------------------------------
Code: 1107D00C
第 209 页