Remedy: Examine the condition of the nozzle and replace if bent. Perform nozzle center measurement once more if the nozzle is not bent. ------------------------------ Code: 1CA10006 Display: 1CA10006 Used by: Vision syst…
Cause: ?? represents the Vision Type from the part data displayed in hexadecimal notation. In the case
where ?? = F1 or F2, the lead width has exceeded the permissible tolerance level.
Remedy: When ?? = F1 or F2, check the lead width and lead width tolerance in element data.
------------------------------
Code: 1CA??066
Display: 1CA??066
Used by:
Cause: ?? represents the Vision Type from the part data displayed in hexadecimal notation. In the case
where ?? = F1 or F2, the lead length has exceeded the permissible tolerance level.
Remedy: When ?? = F1 or F2, check the lead length and lead length tolerance in element data.
------------------------------
Code: 1CA??067
Display: 1CA??067
Used by:
Cause: ?? represents the Vision Type from the part data displayed in hexadecimal notation. In the case
where ?? = F1 or F2, the lead position differs from the position specified in element data.
Remedy: When ?? = F1 or F2, check the position defined by both the L-shaped radical and the lead
radical.
------------------------------
Code: 1CA??068
Display: 1CA??068
Used by:
Cause: ?? represents the Vision Type from the part data displayed in hexadecimal notation. In the case
where ?? = F1 or F2, the part leads cannot be found.
Remedy: When ?? = F1 or F2, check whether or not the leads are bent. If the leads are not bent, ensure
that the Vision height offset has been specified in part data.
------------------------------
Code: 1CA10001
Display: 1CA10001
Used by: Vision system
Cause: The registered part size is larger than the nozzle backplate diameter.
Remedy: Check the body size in part data, or enter a value larger than the part size for the "Backlight".
------------------------------
Code: 1CA10002
Display: 1CA10002
Used by: Vision system
Cause: The part is too small for the specified nozzle.
Remedy: The part is smaller than the diameter of the specified nozzle and cannot be detected. Check the
nozzle data and the body size in part data.
------------------------------
Code: 1CA10003
Display: 1CA10003
Used by: Vision system
Cause: The specified body size is less than "0".
Remedy: Check the body size in part data.
------------------------------
Code: 1CA10004
Display: 1CA10004
Used by: Vision system
Cause: The part outline cannot be determined as the nozzle rotational center does not match with the
part image.
第 1200 页
Remedy: Examine the condition of the nozzle and replace if bent. Perform nozzle center measurement
once more if the nozzle is not bent.
------------------------------
Code: 1CA10006
Display: 1CA10006
Used by: Vision system
Cause: The maximum width for the shortest side of the part is smaller than the permissible part size.
Remedy: Check the pick-up condition of the acquired part image.
------------------------------
Code: 1CA10007
Display: 1CA10007
Used by: Vision system
Cause: The maximum width for the shortest side of the part is larger than the [Part size + nozzle
diameter].
Remedy: The part supply direction is incorrect, or more than half of the nozzle is protruding from the
part.
------------------------------
Code: 1CA1000C
Display: 1CA1000C
Used by: Vision system
Cause: The longest side of the part is 1.05 times smaller than the nozzle diameter.
Remedy: Check the pick-up condition at the acquired part image.
------------------------------
Code: 1CA10010
Display: 1CA10010
Used by: Vision system
Cause: The part supply direction is incorrect. (Cut-check error)
Remedy: Check the part supply direction.
------------------------------
Code: 1CAF3001
Display: 1CAF3001
Used by:
Cause: The lead element data is incorrect. It is not possible to enter consecutive elements with a result
of "128".
Remedy: When result "128" is being used, specify the result for the previous element as a value other
than "128".
------------------------------
Code: 1CAF3002
Display: 1CAF3002
Used by:
Cause: No elements can be found.
Remedy: Ensure that element data exists in part data, and that the result is specified as a value other
than "0".
------------------------------
Code: 1CAF3003
Display: 1CAF3003
Used by:
Cause: The lead element data is incorrect.
Remedy: Ensure that the lead range, including lead width, length, and center tolerance, does not overlap.
------------------------------
Code: 1CAF3005
第 1201 页
Display: 1CAF3005
Used by:
Cause: The defined lead elements do not match with the detected elements.
Remedy: Check the following items in element data.
帴Lead position
帴Lead center tolerance
帴Lead width
帴Lead width tolerance
帴Lead length
帴Lead length tolerance
------------------------------
Code: 1CAF3006
Display: 1CAF3006
Used by:
Cause: The number of detected leads differs from the number of leads specified in element data.
Remedy: Check the following part data items.
帴Vision height offset
帴No. of leads
帴Lead position
帴Lead center tolerance
帴Lead width
帴Lead width tolerance
帴Lead length
帴Lead length tolerance
------------------------------
Code: 1CAF3007
Display: 1CAF3007
Used by:
Cause: Failed to detect any leads.
Remedy: Ensure that the part pick-up position is not excessively out. If the pick-up position is okay,
check the following element data items.
帴Lead position
帴Lead center tolerance
帴Lead width
帴Lead width tolerance
帴Lead length
帴Lead length tolerance
------------------------------
Code: 1CB01001
Display: 1CB01001
Used by: GL541
Cause: The fluorescent plate cannot be found.
Remedy: Check the jig. Confirm that the fluorescent plate is being lit by checking the acquired image.
------------------------------
Code: 1CB01002
Display: 1CB01002
Used by: GL541
Cause: The fluorescent plate is dirty.
Remedy: Clean the fluorescent plate or change the nozzle.
------------------------------
Code: 1CB01003