FUJI错误代码查询.pdf - 第2033页
Code: 2100B1AC Display: not enough memory ! Used by: Cause: The command cannot execute because of a shortage of memory. Remedy: Execute the command after other commands are finished. ------------------------------ Code: …
Code: 2100B1A4
Display: Device error file creat error
Used by:
Cause: Unable to create the device error file.
Remedy: Evaluate and correct the file. If the RAM disk has not enough free memory, shorten the
evaluation time.
------------------------------
Code: 2100B1A5
Display: Device error file open error
Used by:
Cause: Unable to open the device error file.
Remedy: Evaluate and correct the file.
------------------------------
Code: 2100B1A6
Display: Device error file read error
Used by:
Cause: Unable to read the device error file.
Remedy: Evaluate and correct the file.
------------------------------
Code: 2100B1A7
Display: Device error file write error
Used by:
Cause: Unable to write to the device error file.
Remedy: Evaluate and correct the file.
------------------------------
Code: 2100B1A8
Display: History print file creat error.
Used by:
Cause: The history print file could not be created due to a lack of RAM.
Remedy: Re-execute the function. If the problem recurs, re-boot MCS.
------------------------------
Code: 2100B1A9
Display: History print file write error.
Used by:
Cause: The history print file could not be written to due to a lack of RAM.
Remedy: Re-execute the function. If the problem recurs, re-boot MCS.
------------------------------
Code: 2100B1AA
Display: command error
Used by:
Cause: The command could not be executed.
Remedy: Check that the file partitions are in execution format. Check that the file exists. If it does not,
re-install the software.
------------------------------
Code: 2100B1AB
Display: Loading error occurred - program may be destroyed!
Used by:
Cause: Too many commands are being executed in the program. The command cannot be executed.
Remedy: Re-execute the function. If the error recurs, wait for the other commands to finish. Then
execute the function.
------------------------------
第 2032 页
Code: 2100B1AC
Display: not enough memory !
Used by:
Cause: The command cannot execute because of a shortage of memory.
Remedy: Execute the command after other commands are finished.
------------------------------
Code: 2100B1AD
Display: not found.
Used by:
Cause: The command does not exist.
Remedy: Check that the command was input correctly.
------------------------------
Code: 2100B1B3
Display: Undecided nozzle size for FCP6.
Used by:
Cause: An attempt was made to acquire a nozzle number from the nozzle assignment table but the nozzle
size set in Part data could not be found.
Remedy: Return to the nozzle assignment table, the Part data and the production program used during
production and then re-execute the Analyzer.
------------------------------
Code: 2100B1B4
Display: Coplanarity display file create error.
Used by:
Cause: The directory for creating the file used to display the results of the coplanarity check does not
exist.
Remedy: After completing the operation presently being executed, select "NO" at the analyzer screen to
end. Return to the UCI screen and re-execute the analyzer.
------------------------------
Code: 2100B1B5
Display: Coplanarity display file open error.
Used by:
Cause: The file for displaying the coplanarity check results cannot be opened.
Remedy: At the analyzer screen select "NO" to end, return to the UCI screen, and re-execute the analyzer.
------------------------------
Code: 2100B1B6
Display: Coplanarity display file read error.
Used by:
Cause: The file for displaying the coplanarity check results cannot be read.
Remedy: Select "NO" to end at the analyzer screen, return to the UCI screen, and re-execute the analyzer.
------------------------------
Code: 2100B1B7
Display: Coplanarity display file write error.
Used by:
Cause: Data cannot be written to the file for displaying the results of the coplanarity check.
Remedy: After completing the operation presently being executed, select "NO" at the analyzer screen to
end. Return to the UCI screen and re-execute the analyzer. Alternatively shorten the time frame being
analyzed.
------------------------------
Code: 2100B1B8
Display: Mainte coplanarity work file create error.
Used by:
第 2033 页
Cause: The coplanarity check work file for maintenence could not be created.
Remedy: Select "NO" to end at the Analyzer screen and then re-execute the Analyzer. If the error recurs
reset the MCS.
------------------------------
Code: 2100B1B9
Display: Mainte coplanarity work file open error.
Used by:
Cause: The coplanarity check work file for maintenance could not be opened.
Remedy: Select "NO" to end at the Analyzer screen and then re-execute the Analyzer.
------------------------------
Code: 2100B1BA
Display: Mainte coplanarity work file read error.
Used by:
Cause: Data could not be read from the maintenance coplanarity check work file.
Remedy: Select "NO" to end at the Analyzer screen and then re-execute the Analyzer.
------------------------------
Code: 2100B1BB
Display: Mainte coplanarity work file write error.
Used by:
Cause: Data could not be written to the maintenance coplanarity check work file.
Remedy: Select "NO" to end at the Analyzer screen and then re-execute the Analyzer.
------------------------------
Code: 2100B1BC
Display: Coplanarity error file creat error.
Used by:
Cause: The coplanarity check device error file could not be created.
Remedy: Select "NO" to end at the Analyzer screen and then re-execute the Analyzer.
------------------------------
Code: 2100B1BD
Display: Coplanarity error file write error.
Used by:
Cause: Data could not be written to the coplanarity check device error file.
Remedy: Select "NO" to end at the Analyzer screen and then re-execute the Analyzer.
------------------------------
Code: 2100B1BE
Display: Coplanarity error (MC) file not found.
Used by:
Cause: The coplanarity check device error analysis file could not be opened.
Remedy: Re-execute the Analyzer.
------------------------------
Code: 2100B1BF
Display: Coplanarity error (MC) file create error.
Used by:
Cause: The coplanarity check device error analysis file could not be created.
Remedy: Re-execute the Analyzer.
------------------------------
Code: 2100B1C0
Display: Coplanarity error (MC) file open error.
Used by:
Cause: The coplanarity check device error analysis file could not be opened.
Remedy: Re-execute the Analyzer.
第 2034 页